TDK 1500W, 750W technical manual STATUS, Error and SRQ Registers, Status Control Commands

Page 70

7.10.6

Status Control Commands

 

Refer to Section 7-8 for definition of the registers.

 

#

 

Command

 

Description

1

 

STT?

Reads the complete power supply status.

 

 

 

Returns ASCII characters representing the following data, separated by commas:

 

 

 

MV<actual (measured) voltage>

PC<programmed (set) current>

 

 

 

PV<programmed (set) voltage>

SR<status register, 2-digit hex>

 

 

 

MC<actual (measured) current>

FR<fault register, 2-digit hex>

 

 

 

Example response: MV(45.201),PV(45), MC(4.3257), PC(10), SR(30), FR(00)

2

 

FLT?

Reads Fault Conditional Register. Returns 2-digit hex.

3

 

FENA

Set Fault Enable Register using 2-digit hex.

4

 

FENA?

Reads Fault Enable Register. Returns 2-digit hex.

5

 

FEVE?

Reads Fault Event Register. Returns 2-digit hex. Clears bits of Fault Event Register.

6

 

STAT?

Reads Status Conditional Register. Returns 2-digit hex.

7

 

SENA

Sets Status Enable Register using 2-digit hex.

8

 

SENA?

Reads Status Enable Register. Returns 2-digit hex.

9

 

SEVE?

Reads Status Event register. Returns 2-digit hex. Clears bits of Status Event register.

7.11 STATUS, ERROR AND SRQ REGISTERS

7.11.1 General Description

This Section describes the various status error and SRQ registers structure. The registers can be read or set via the RS232/RS485 commands. When using the IEEE option, refer to the User’s Manual for GenesysTM Power Supply IEEE Programming Interface.

Refer to Fig. 7-7 for the Status and Error Registers Diagram.

62

83-507-013 Rev. D

Image 70
Contents Genesystm 750W/1500W Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and Connectors ………...……… Remote Analog PROGRAMMING……………………………………………… Isolated Analog Programming OPTION………………………………… Disclaimer Limitation of WarrantyWarranty Service Trademark InformationSafety Instructions Environmental Conditions SICHERHEITS-INSTALLATIONS Anweisungen Anderungen and Bauteileersatz Sicherheits-und WarnsymboleUmweltbedingungen Introduction Features and optionsGeneral Information General DescriptionAnalog voltage programming and monitoring Multiple output power systemControl via the serial communication port Parallel operationAccessories Specifications ChapterVout Supplemental Characteristics Genesystm 750W & 1500W Power Supplies Outline Drawings Preparation for USE InstallationGeneral Initial InspectionsAC Source Requirements AC Input Power ConnectionLOCATON, Mounting and Cooling Rack Mount Slides optionalAC Input Wire Connection, 1500W models AC Input Connector, 1500W modelsAC Input Connector, 750W models AC Input CordGeneral TURN-ON Checkout ProcedurePrior to Operation OVP Check Constant Voltage CheckConstant Current Check UVL CheckConnecting the Load Wire termination AWGInductive loads Noise and Impedance EffectsMaking the load connections 6V to 60V Models Wire terminal lug 2 places 80V to 600V ModelsLoad wires connection to the output connector Connecting single loads, remote sensing Connecting single loads, local sensing defaultConnecting multiple loads, radial distribution method Multiple load connection with distribution terminals Grounding outputsLocal and Remote Sensing Sense wiringOutput Terminal Grounding Local sensing10.4 J2 sense connector technical information Remote sensingFront and Rear Panel Controls and Connectors Front Panel Controls and IndicatorsAuxiliary Function Rear Panel Connections and Controls Rear panel connections and controlsRear Panel SW1 Setup Switch Resetting the SW1 switch 1 SW1 position functionRear Panel J1 Programming and Monitorng Connector Making J1 connectionsIfcom SignalEnain LocalConstant Current Mode Constant Voltage ModeLocal Operation Over Voltage Protection OVP Setting the OVP levelResetting the OVP circuit Automatic CrossoverFoldback Protection Output SHUT-OFF SO Control VIA Rear Panel J1 ConnectorUnder Voltage Limit UVL Output ON/OFF ControlCV/CC Signal ENABLE/DISABLE Control VIA Rear Panel J1 ConnectorPsok Signal Auto-restart mode Over Temperature Protecton OTPLast Setting Memory Safe-start modeSeries Operation Series connection for increased output voltageSeries connection for positive and negative output voltage Series connection for positive/negative output voltagesParallel Operation Master and Slave units default operation Advanced parallel configurationSetting the units as Master or Slave Connection to the loadCurrent display accuracy To release units from Slave modeAST OFF *OUT OFF Unlocked front panel DAISY-CHAIN ConnectionFront Panel Locking Locked front panelRemote Analog Programming LOCAL/REMOTE Analog IndicationDown Remote voltage programming connectionResisitive Programming of Output Voltage and Current Limit Remote resistive programmingRemote Monitoring of Output Voltage and Current RS232 & RS485 Remote Control Configuration6 RS232/RS485 port in Local mode Rear Panel RS232/RS485 ConnectorFront panel in Remote mode MD Mode SRQ MD Mode Option Factory Installed MD Mode DescriptionMD Mode enable Serial communication mode MD Mode SRQ RetransmissionConnecting Power Supplies to RS232 or RS485 BUS Single power supplyCommunication Interface Protocol Error Messages Command SET DescriptionID Control Commands Initialization Control CommandsOutput Control Commands FILTER? DVC?Filter OUT?Global Output Commands Disable SRQ retransmission MD Mode Option Required Single Byte CommandsEnable MD Mode MD Mode Option Required Enable SRQ retransmission MD Mode Option RequiredTest if MD Mode is Installed Addressed commands with response Read registersPrint Power On Time Addressed commands without response Acknowledge SRQ1010 None Disable retransmission of SRQs by GEN750W models GEN1500W models Current programming range STATUS, Error and SRQ Registers 10.6 Status Control CommandsConditional Registers Status RegistersService Request Enable and Event Registers BITFault Enable Register Fault Event RegisterStatus Enable Register Status Event RegisterSerial Communication Test SET-UP Power supply set-upCommunication Test 1 0-5V/0-10V Option PN IS510 SpecificationsIsolated Analog Programming Option PPM/CIsolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance Fuse Rating OUP