TDK 1500W, 750W technical manual Auxiliary Function

Page 36

Table 4-1: Front Panel Controls and Indicators

Number

Control/Indicator

Description

Section

4

CURRENT display

4 digit, 7 segment LED display. Normally displays the Out-

 

 

 

put Current. When the PREV button is pressed, the display

 

 

 

indicates the programmed setting of Output Current.

 

5

CURRENT indicator

Green LED, lights for Constant-Current mode operation

 

6

CURRENT control

High resolution rotary encoder for adjusting the Output Cur-

5.2.2

 

 

rent.

7.2.4

 

 

Auxiliary Function:

5.15.2

 

 

1. Selects the Baud-Rate of communication port.

 

 

 

2. Set desired mode of the Master Power Supply in Ad-

 

 

 

vanced parallel operation.

 

7

OUT button

Main function: Output ON/OFF control. Press OUT to set

5.6

 

 

the output On or Off. Press to reset and turn On the output

5.11

 

 

after OVP or FOLD alarm events have occurred. Auxiliary

 

 

 

function: Selects between “Safe-Start” and “Auto-Restart”

 

 

 

modes. Press and hold OUT button to toggle between

 

 

 

“Safe-Start” and “Auto-Restart”. The VOLT display will cycle

 

 

 

between “SAF” and “AUT”. Releasing the OUT button while

 

 

 

one of the modes is displayed, selects that mode.

 

8

OUT indicator

Green LED, lights when the DC output is enabled.

 

9

REM/LOC button

Main function: Go to local. Press REM/LOC to put the unit

7.2.5

 

 

into Local mode (REM/LOC button is disabled at Local

7.2.2

 

 

Lockout mode).

 

 

7.2.4

 

 

Auxiliary function: Address and Baud Rate setting. Press

 

 

and hold REM/LOC for 3 sec. to set the Address with the

 

 

 

VOLTAGE encoder and the Baud Rate with the CURRENT

 

 

 

encoder.

 

10

REM/LOC indicator

Green LED, lights when the unit is in Remote mode.

 

11

FOLD button

Foldback protection control.

5.5

 

 

-Press FOLD to set Foldback protection to On.

 

 

 

-To release Foldback alarm even, press OUT to enable the

 

 

 

output and re-arm the protection.

 

 

 

-Press FOLD again to cancel the Foldback protection.

 

12

FOLD indicator

Green LED, lights when Foldback protection is On.

 

13

OVP/UVL button

Over Voltage Protection and Under Voltage limit setting.

5.3

 

 

-Press once to set OVP using VOLTAGE encoder (the cur-

5.4

 

 

rent display shows “OUP”)

 

 

 

 

 

-Press again to set the UVL using VOLTAGE encoder (the

 

 

 

current display shows “UUL”).

 

 

 

 

 

28

83-507-013 Rev. D

Image 36
Contents Genesystm 750W/1500W Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and Connectors ………...……… Remote Analog PROGRAMMING……………………………………………… Isolated Analog Programming OPTION………………………………… Limitation of Warranty Warranty ServiceDisclaimer Trademark InformationSafety Instructions Environmental Conditions SICHERHEITS-INSTALLATIONS Anweisungen Sicherheits-und Warnsymbole Anderungen and BauteileersatzUmweltbedingungen Features and options General InformationIntroduction General DescriptionMultiple output power system Control via the serial communication portAnalog voltage programming and monitoring Parallel operationAccessories Specifications ChapterVout Supplemental Characteristics Genesystm 750W & 1500W Power Supplies Outline Drawings Installation GeneralPreparation for USE Initial InspectionsAC Input Power Connection LOCATON, Mounting and CoolingAC Source Requirements Rack Mount Slides optionalAC Input Connector, 1500W models AC Input Connector, 750W modelsAC Input Wire Connection, 1500W models AC Input CordTURN-ON Checkout Procedure GeneralPrior to Operation Constant Voltage Check Constant Current CheckOVP Check UVL CheckConnecting the Load Wire termination AWGNoise and Impedance Effects Inductive loadsMaking the load connections 6V to 60V Models Wire terminal lug 2 places 80V to 600V ModelsLoad wires connection to the output connector Connecting single loads, local sensing default Connecting single loads, remote sensingConnecting multiple loads, radial distribution method Multiple load connection with distribution terminals Grounding outputsSense wiring Output Terminal GroundingLocal and Remote Sensing Local sensing10.4 J2 sense connector technical information Remote sensingFront and Rear Panel Controls and Connectors Front Panel Controls and IndicatorsAuxiliary Function Rear Panel Connections and Controls Rear panel connections and controlsRear Panel SW1 Setup Switch Resetting the SW1 switch 1 SW1 position functionRear Panel J1 Programming and Monitorng Connector Making J1 connectionsSignal EnainIfcom LocalConstant Voltage Mode Constant Current ModeLocal Operation Setting the OVP level Resetting the OVP circuitOver Voltage Protection OVP Automatic CrossoverOutput SHUT-OFF SO Control VIA Rear Panel J1 Connector Under Voltage Limit UVLFoldback Protection Output ON/OFF ControlENABLE/DISABLE Control VIA Rear Panel J1 Connector CV/CC SignalPsok Signal Over Temperature Protecton OTP Last Setting MemoryAuto-restart mode Safe-start modeSeries Operation Series connection for increased output voltageSeries connection for positive and negative output voltage Series connection for positive/negative output voltagesParallel Operation Advanced parallel configuration Setting the units as Master or SlaveMaster and Slave units default operation Connection to the loadTo release units from Slave mode Current display accuracyAST OFF *OUT OFF DAISY-CHAIN Connection Front Panel LockingUnlocked front panel Locked front panelRemote Analog Programming LOCAL/REMOTE Analog IndicationDown Remote voltage programming connectionResisitive Programming of Output Voltage and Current Limit Remote resistive programmingRemote Monitoring of Output Voltage and Current RS232 & RS485 Remote Control ConfigurationRear Panel RS232/RS485 Connector 6 RS232/RS485 port in Local modeFront panel in Remote mode MD Mode Option Factory Installed MD Mode Description MD Mode enable Serial communication modeMD Mode SRQ MD Mode SRQ RetransmissionConnecting Power Supplies to RS232 or RS485 BUS Single power supplyCommunication Interface Protocol Error Messages Command SET DescriptionInitialization Control Commands ID Control CommandsOutput Control Commands DVC? FilterFILTER? OUT?Global Output Commands Single Byte Commands Enable MD Mode MD Mode Option RequiredDisable SRQ retransmission MD Mode Option Required Enable SRQ retransmission MD Mode Option RequiredAddressed commands with response Read registers Print Power On TimeTest if MD Mode is Installed Addressed commands without response Acknowledge SRQ1010 None Disable retransmission of SRQs by GEN750W models GEN1500W models Current programming range STATUS, Error and SRQ Registers 10.6 Status Control CommandsConditional Registers Status RegistersService Request Enable and Event Registers BITFault Enable Register Fault Event RegisterStatus Enable Register Status Event RegisterPower supply set-up Serial Communication Test SET-UPCommunication Test Specifications Isolated Analog Programming Option1 0-5V/0-10V Option PN IS510 PPM/CIsolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance Fuse Rating OUP