WARNING
Some components inside the power supply are at AC voltage even when the On/Off switch is in the “Off” position. To avoid electric shock hazard, disconnect the line cord and load and wait two minutes before removing cover.
3.7.1 AC Input Connector, 1500W models
The AC input connector is a
1.Wire diameter: 12AWG or 10AWG.
2.Tightening torque: 6.5 - 7.0
3.7.2 AC Input Connector, 750W models
An IEC connector is provided on the rear panel for connecting the unit to the AC power source with an AC cord. The IEC connector also provides the safety ground connection while the AC cord is plugged into an appropriate AC receptacle.
WARNING
The AC input cord is the disconnect device of the power supply. The plug must be readily identifiable and accessible to the user. The AC input cord must be no longer than 3m.
3.7.3 AC Input Cord
Refer to Section 1.3.4 for details of the AC input cords recommended for the 750W and the 1500W models.
3.7.4AC Input Wire Connection, 1500W models
1.Strip the outside insulation of the AC cable approx. 10cm (3.94 inches). Trim the wires so that the ground wire is 10mm (0.4 inches) longer than the other wires. Strip 14mm (0.55 inches) at the end of each of the wires.
2.Unscrew the base of the strain relief from the
3.Slide the
Screw-on
Locknut
Fig.3-2: Stripped Wires installed in Strain Relief
15