TDK 750W, 1500W technical manual Conditional Registers, Status Registers

Page 71

 

Command Error (”Cnn”)

 

One response for every command

 

Execution Error (”Enn”)

 

or query received.

 

 

Response

 

Query Response (”message”)

 

messages

 

 

 

 

Command Response (”OK”)

 

 

 

 

 

Status Registers

Serial

 

LSB

Condition

Enable

Event

TXD

Constant Voltage

0

CV

 

CV

 

 

1

 

 

Constant Current

 

CC

 

CC

“Inn” and CR

 

2

 

No Fault

 

NFLT

 

NFLT

 

 

3

 

 

Fault

 

FLT

 

FLT

SRQ

 

4

 

Auto Start

 

AST

0

0

Messages

 

5

Fold Enabled

 

FDE

0

0

One SRQ when SEVE goes

 

6

Spare

MSB

0

0

0

from all zeroes to any bit set.

7

Local Mode

LCL

 

LCL

Setting more SEVE bits does

 

 

 

 

 

“STAT?”

“SENA xx” “SEVE?”

not cause more SRQs.

 

 

 

 

“SENA?”

 

 

 

 

 

 

 

Positive Logic:

 

 

 

 

 

 

0 = No Event

 

 

 

 

 

 

1 = Event Occured

 

 

 

Fault Registers

 

 

LSB

Condition

 

Enable

Event

Spare

0

0

 

 

0

 

1

 

 

AC Fail

 

AC

 

 

AC

 

2

 

 

Over Temperature

 

OTP

 

 

OTP

 

3

 

 

Foldback (tripped)

 

FLD

 

 

FLD

 

4

 

 

Over Volt Prot

 

OVP

 

 

OVP

 

5

 

 

Shut Off (rear panel)

 

SO

 

 

SO

 

6

 

 

Output Off (front panel)

MSB

OFF

 

 

OFF

7

 

 

Enable Open

ENA

 

 

ENA

 

 

 

 

 

 

 

“FLT?”

“FENA xx”

“FEVE?”

 

 

 

 

“FENA?”

 

Fig.7-7: Status and Error Registers Diagram

7.11.2 Conditional Registers

The fault Condition Register and the Status Condition Register are read only registers that the user may read to see the condition of the Power supply. Refer to Table 7-8 for description of the Fault Condition Register bits and Table 7-9 for the Status Condition register bits.

63

83-507-013 Rev. D

Image 71
Contents Genesystm 750W/1500W Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and Connectors ………...……… Remote Analog PROGRAMMING……………………………………………… Isolated Analog Programming OPTION………………………………… Trademark Information Limitation of WarrantyWarranty Service DisclaimerSafety Instructions Environmental Conditions SICHERHEITS-INSTALLATIONS Anweisungen Umweltbedingungen Sicherheits-und WarnsymboleAnderungen and Bauteileersatz General Description Features and optionsGeneral Information IntroductionParallel operation Multiple output power systemControl via the serial communication port Analog voltage programming and monitoringAccessories Chapter SpecificationsVout Supplemental Characteristics Genesystm 750W & 1500W Power Supplies Outline Drawings Initial Inspections InstallationGeneral Preparation for USERack Mount Slides optional AC Input Power ConnectionLOCATON, Mounting and Cooling AC Source RequirementsAC Input Cord AC Input Connector, 1500W modelsAC Input Connector, 750W models AC Input Wire Connection, 1500W modelsPrior to Operation TURN-ON Checkout ProcedureGeneral UVL Check Constant Voltage CheckConstant Current Check OVP CheckConnecting the Load AWG Wire terminationMaking the load connections 6V to 60V Models Noise and Impedance EffectsInductive loads 80V to 600V Models Wire terminal lug 2 placesLoad wires connection to the output connector Connecting multiple loads, radial distribution method Connecting single loads, local sensing defaultConnecting single loads, remote sensing Grounding outputs Multiple load connection with distribution terminalsLocal sensing Sense wiringOutput Terminal Grounding Local and Remote SensingRemote sensing 10.4 J2 sense connector technical informationFront Panel Controls and Indicators Front and Rear Panel Controls and ConnectorsAuxiliary Function Rear panel connections and controls Rear Panel Connections and ControlsRear Panel SW1 Setup Switch 1 SW1 position function Resetting the SW1 switchMaking J1 connections Rear Panel J1 Programming and Monitorng ConnectorLocal SignalEnain IfcomLocal Operation Constant Voltage ModeConstant Current Mode Automatic Crossover Setting the OVP levelResetting the OVP circuit Over Voltage Protection OVPOutput ON/OFF Control Output SHUT-OFF SO Control VIA Rear Panel J1 ConnectorUnder Voltage Limit UVL Foldback ProtectionPsok Signal ENABLE/DISABLE Control VIA Rear Panel J1 ConnectorCV/CC Signal Safe-start mode Over Temperature Protecton OTPLast Setting Memory Auto-restart modeSeries connection for increased output voltage Series OperationSeries connection for positive/negative output voltages Series connection for positive and negative output voltageParallel Operation Connection to the load Advanced parallel configurationSetting the units as Master or Slave Master and Slave units default operationAST OFF *OUT OFF To release units from Slave modeCurrent display accuracy Locked front panel DAISY-CHAIN ConnectionFront Panel Locking Unlocked front panelLOCAL/REMOTE Analog Indication Remote Analog ProgrammingRemote voltage programming connection DownRemote resistive programming Resisitive Programming of Output Voltage and Current LimitRemote Monitoring of Output Voltage and Current Configuration RS232 & RS485 Remote ControlFront panel in Remote mode Rear Panel RS232/RS485 Connector6 RS232/RS485 port in Local mode MD Mode SRQ Retransmission MD Mode Option Factory Installed MD Mode DescriptionMD Mode enable Serial communication mode MD Mode SRQSingle power supply Connecting Power Supplies to RS232 or RS485 BUSCommunication Interface Protocol Command SET Description Error MessagesOutput Control Commands Initialization Control CommandsID Control Commands OUT? DVC?Filter FILTER?Global Output Commands Enable SRQ retransmission MD Mode Option Required Single Byte CommandsEnable MD Mode MD Mode Option Required Disable SRQ retransmission MD Mode Option RequiredAddressed commands without response Acknowledge SRQ Addressed commands with response Read registersPrint Power On Time Test if MD Mode is Installed1010 None Disable retransmission of SRQs by GEN750W models GEN1500W models Current programming range 10.6 Status Control Commands STATUS, Error and SRQ RegistersStatus Registers Conditional RegistersBIT Service Request Enable and Event RegistersFault Event Register Fault Enable RegisterStatus Event Register Status Enable RegisterCommunication Test Power supply set-upSerial Communication Test SET-UP PPM/C SpecificationsIsolated Analog Programming Option 1 0-5V/0-10V Option PN IS510Isolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance OUP Fuse Rating