TDK 1500W, 750W technical manual Status Enable Register, Status Event Register

Page 74

3. Status Enable Register

The Status Enable Register is set by the user to Enable SRQs for changes in power supply status.

Table 7-12: Status Enable Register

BIT

Status name

Status symbol

Bit Set condition

Bit reset condition

 

 

 

 

 

0 (LSB)

Constant Voltage

CV

 

User command: “SENA nn”

 

 

 

User command:

is received, where nn is

1

Constant Current

CC

hexadecimal bits.

“SENA nn” is

2

No Fault

NFLT

received, where

If “nn”=00, no SRQ is sent

 

 

 

nn is hexadecimal

when there is a change in

3

 

FLT

Fault active

bits.

Status Condition Register.

 

 

 

 

 

4

Auto-Restart enabled

AST

Always zero

Always zero

 

 

 

 

 

5

Fold enabled

FDE

Always zero

Always zero

 

 

 

 

 

6

Spare

Spare

Always zero

Always zero

 

 

 

 

 

7 (MSB)

Local Mode

LCL

“SENA nn”

“SENA nn”

command

command

 

 

 

4. Status Event Register

The Status Event Register will set a bit if a change in the power supply status occurs and it is en- abled. The register is cleared when the “SEVE?” or “CLS” commands are received. A change in this register will generate SRQ.

Table 7-13: Status Event Register

BIT

Status name

Status symbol

Bit Set condition

Bit reset condition

 

 

 

 

 

0 (LSB)

Constant Voltage

CV

Changes in status

 

occur and it is

 

 

 

 

Enabled.

 

1

Constant Current

CC

The change can

 

 

 

 

set a bit, but when

 

2

No Fault

NFLT

 

the change clears

Entire Event Register is

 

 

 

the bit remains

cleared when user sends

3

Fault active

FLT

set.

“SEVE?” command to read

 

 

 

4

Auto-Restart enabled

0

Always zero

the register.

 

 

 

 

“CLS” and power-up also

5

Fold enabled

0

Always zero

clear the Status Event

6

Spare

0

Always zero

Register.

 

 

 

 

 

 

 

 

 

Unit is set to Local

 

7 (MSB)

Local Mode

LCL

by pressing front

 

panel REM/LOC

 

 

 

 

 

 

 

 

button.

 

 

 

 

 

 

66

83-507-013 Rev. D

Image 74
Contents Genesystm 750W/1500W Page Page Genesys Manual Supplement Table of Contents Front and Rear Panel Controls and Connectors ………...……… Remote Analog PROGRAMMING……………………………………………… Isolated Analog Programming OPTION………………………………… Disclaimer Limitation of WarrantyWarranty Service Trademark InformationSafety Instructions Environmental Conditions SICHERHEITS-INSTALLATIONS Anweisungen Umweltbedingungen Sicherheits-und WarnsymboleAnderungen and Bauteileersatz Introduction Features and optionsGeneral Information General DescriptionAnalog voltage programming and monitoring Multiple output power systemControl via the serial communication port Parallel operationAccessories Specifications ChapterVout Supplemental Characteristics Genesystm 750W & 1500W Power Supplies Outline Drawings Preparation for USE InstallationGeneral Initial InspectionsAC Source Requirements AC Input Power ConnectionLOCATON, Mounting and Cooling Rack Mount Slides optionalAC Input Wire Connection, 1500W models AC Input Connector, 1500W modelsAC Input Connector, 750W models AC Input CordPrior to Operation TURN-ON Checkout ProcedureGeneral OVP Check Constant Voltage CheckConstant Current Check UVL CheckConnecting the Load Wire termination AWGMaking the load connections 6V to 60V Models Noise and Impedance EffectsInductive loads Wire terminal lug 2 places 80V to 600V ModelsLoad wires connection to the output connector Connecting multiple loads, radial distribution method Connecting single loads, local sensing defaultConnecting single loads, remote sensing Multiple load connection with distribution terminals Grounding outputsLocal and Remote Sensing Sense wiringOutput Terminal Grounding Local sensing10.4 J2 sense connector technical information Remote sensingFront and Rear Panel Controls and Connectors Front Panel Controls and IndicatorsAuxiliary Function Rear Panel Connections and Controls Rear panel connections and controlsRear Panel SW1 Setup Switch Resetting the SW1 switch 1 SW1 position functionRear Panel J1 Programming and Monitorng Connector Making J1 connectionsIfcom SignalEnain LocalLocal Operation Constant Voltage ModeConstant Current Mode Over Voltage Protection OVP Setting the OVP levelResetting the OVP circuit Automatic CrossoverFoldback Protection Output SHUT-OFF SO Control VIA Rear Panel J1 ConnectorUnder Voltage Limit UVL Output ON/OFF ControlPsok Signal ENABLE/DISABLE Control VIA Rear Panel J1 ConnectorCV/CC Signal Auto-restart mode Over Temperature Protecton OTPLast Setting Memory Safe-start modeSeries Operation Series connection for increased output voltageSeries connection for positive and negative output voltage Series connection for positive/negative output voltagesParallel Operation Master and Slave units default operation Advanced parallel configurationSetting the units as Master or Slave Connection to the loadAST OFF *OUT OFF To release units from Slave modeCurrent display accuracy Unlocked front panel DAISY-CHAIN ConnectionFront Panel Locking Locked front panelRemote Analog Programming LOCAL/REMOTE Analog IndicationDown Remote voltage programming connectionResisitive Programming of Output Voltage and Current Limit Remote resistive programmingRemote Monitoring of Output Voltage and Current RS232 & RS485 Remote Control ConfigurationFront panel in Remote mode Rear Panel RS232/RS485 Connector6 RS232/RS485 port in Local mode MD Mode SRQ MD Mode Option Factory Installed MD Mode DescriptionMD Mode enable Serial communication mode MD Mode SRQ RetransmissionConnecting Power Supplies to RS232 or RS485 BUS Single power supplyCommunication Interface Protocol Error Messages Command SET DescriptionOutput Control Commands Initialization Control CommandsID Control Commands FILTER? DVC?Filter OUT?Global Output Commands Disable SRQ retransmission MD Mode Option Required Single Byte CommandsEnable MD Mode MD Mode Option Required Enable SRQ retransmission MD Mode Option RequiredTest if MD Mode is Installed Addressed commands with response Read registersPrint Power On Time Addressed commands without response Acknowledge SRQ1010 None Disable retransmission of SRQs by GEN750W models GEN1500W models Current programming range STATUS, Error and SRQ Registers 10.6 Status Control CommandsConditional Registers Status RegistersService Request Enable and Event Registers BITFault Enable Register Fault Event RegisterStatus Enable Register Status Event RegisterCommunication Test Power supply set-upSerial Communication Test SET-UP 1 0-5V/0-10V Option PN IS510 SpecificationsIsolated Analog Programming Option PPM/CIsolated Programming & Monitoring Connector Setup and Operating Instructions Maintenance Fuse Rating OUP