4.Route the AC wires to the input connector terminals as required. To connect the wires, loosen the terminal screw, insert the stripped wire into the terminal and tighten the screw securely
5.Route the wires inside the cover to prevent pinching. Fasten the cover to the unit using the M3x8 Flat Head screws provided. Refer to
L N
Cover
M3x8
Flat Head screws
(2 places)
Assembled Strain Relief
Fig.3-3: AC input cover and strain relief, 1500W models
3.8 TURN-ON CHECKOUT PROCEDURE
3.8.1General
The following procedure ensures that the power supply is operational and may be used as a basic in- coming inspection check. Refer to Fig.
3.8.2Prior to Operation
1.Ensure that the power supply is configured to the default setting:
On/Off switch at Off position.
Dip switch: All positions at Down (“Off”) position.
J2 Sense connector: Configured to Local Sense as shown in Fig.
1 | Remote (+) sense | Plug P/N: |
2 | Local (+) sense | (Phoenix) |
3Not connected
4Local
5Remote
Fig.3-4: J2 Sense connector default connection
For units equipped with IEEE option, ensure that the IEEE_En switch is in Up (default) po- sition (Refer to