CPM1A Features and Functions |
|
| Section | ||||
|
|
|
|
|
|
| |
Mode | Input functions | Input method | Count | Count | Control methods | ||
|
|
| frequency | range |
|
| |
|
|
|
|
|
|
| |
Up/Down | 00000: | 2.5 kHz | Target value control: | ||||
| 00001: | 4⋅ inputs |
| to | Up to 16 target values and interrupt | ||
| 00002: |
|
| 32767 | subroutine numbers can be | ||
|
|
|
|
| registered. | ||
|
|
|
|
| Zone comparison control: | ||
Incremental | 00000: Count input | Individual inputs | 5.0 kHz | 0 | |||
Up to 8 sets of upper limit values, | |||||||
| 00001: See note. |
|
| to | |||
|
|
| lower limit values, and interrupt | ||||
| 00002: Reset input |
|
| 65535 | |||
|
|
| subroutine numbers can be | ||||
|
|
|
|
| |||
|
|
|
|
| registered. | ||
|
|
|
|
|
|
|
Note In incremental mode, this input (00001) can be used as an regular input.
Expansion Unit Functions
Analog I/O Unit Functions
Two analog inputs: input range 0 to 10 V, 1 to 5 V, or 4 to 20 mA
One analog output: output range 0 to 10 V,
Temperature Sensor Unit Functions
Thermocouple input
K:
0.0° to 500.0° C (0.0° to 900.0° F)
J:
Platinum resistance thermometer input
Pt100:
JPt100:
CompoBus/S Slave Functions (CPM1A-SRT21)
Exchanges 8 input bits and 8 output bits of data with the Master Unit.
9