Omron CPM1A operation manual Offline and Online Operations

Page 85

Support Software CapabilitiesSection 4-1

4-1-5 Offline and Online Operations

 

 

The following operations are possible either online or offline from the PC.

 

 

 

 

Group

Name

 

Description

 

 

 

 

System Setup

PC model

 

Specifies the model of PC that is being programmed or that is connected to the

(see note)

 

 

computer.

 

 

 

 

 

PC Interface

 

C-series PCs: Specifies whether communications with the PC are performed

 

 

 

through a SYSMAC NET Link Unit, peripheral interface, or a Host

 

 

 

Link (RS-232C) interface and the computer port (COM1 or COM2)

 

 

 

to use. When a Host Link Unit is used, it also specifies the port

 

 

 

number and baud rate.

 

 

 

CVM1 PCs: Used to specify the communications protocol for communications

 

 

 

with the PC, i.e., peripheral or Host Link (RS-232C) interface. The

 

 

 

baud rate, PC unit number, parity, data length, and number of stop

 

 

 

bits are designated.

 

 

 

 

 

Network

 

Specifies the network address, node number, and data code type of the SYSMAC

 

address

 

NET Link Unit communicating with the SSS on the SYSMAC NET System. The

 

 

 

address determines the PC to be connected to for online operations.

 

 

 

With CVM1 PCs this setting is also used to specify the PC being communicated

 

 

 

with through networks when connected via a peripheral or Host Link interface.

 

 

 

 

 

I/O table –

 

Specifies whether the I/O table and data link tables are transferred to the user

 

UM transfer

 

program area when the user program is transferred between the computer and

 

 

 

PC or PROM Writer. (C-series PCs only)

 

 

 

 

 

EPROM

 

Specifies the baud rate and port number of the PROM Writer connected to the

 

interface

 

computer. (C-series PCs only)

 

Printer model

 

Specifies the printer model.

 

 

 

 

 

Data disk drive

 

Specifies the data disk drive.

 

 

 

 

 

OutBit

 

Specifies whether I/O comments or instruction comments are displayed at the

 

Comment Type

 

TIM/CNT, DIFU/DIFD, KEEP, and STEP/SNXT comment display positions.

 

 

 

(C-series PCs only)

 

 

 

 

 

Exit to DOS

 

Terminates SSS operation and returns to DOS.

Note When the SSS is operating in online mode, the only functions available on the System Setup Menu are “I/O table – UM transfer,” “Data disk drive,” and “Exit to DOS.”

73

Image 85
Contents CPM1A CPM1A Programmable Controllers  Omron Omron Product ReferencesTable of Contents Appendices About this Manual Precautions Safety Precautions General PrecautionsIntended Audience Application Precautions Operating Environment PrecautionsXiv Application Precautions Backup method Data Applicable Directives EC DirectivesConcepts Conformance to EC DirectivesXviii Section 1 CPM1A Features CPM1A Features and FunctionsSection NT Link Communications CompoBus/S I/O Link Units Using the PTStandard Peripheral Devices Programming is PossibleCPU Units 2 I/O Terminal and IR Bit AllocationExpansion I/O Units Unit Relay output Transistor output Sink type Source type3 CPM1A Functions Control Corresponding IR word Setting range BCDSet value Word Word 001 or later PC model Input bits Response time PC model Input bits Min. input pulse width Mode FunctionPulse output single-phase output CompoBus/S Slave Functions CPM1A-SRT21 Temperature Sensor Unit FunctionsCPU Unit and Expansion I/O Unit Configuration System ConfigurationCPU Unit and Expansion Unit CPM1A CPU UnitsUnit Max. number Inputs Outputs Model Units Expansion I/O UnitsExpansion Units Host Link CommunicationsProgrammable Terminal Connecting to aAdapters and Cables One-to-one PC Link CommunicationsName Usage Model number One-to-one NT Link Communications Name SpecificationsCompoBus/S I/O Link Connections Peripheral Device ConnectionsName Model number Sysmac Support Software SYSMAC-CPT SupportPrevious specifications New specifications Relevant pages Revised SpecificationsUnit Specifications and Components General Specifications SpecificationsCPM1A-10CDR-j CPM1A-20CDR-j CPM1A-30CDR-j CPM1A-40CDR-j Characteristics Memory Backup CPU Unit Input Specifications 3 I/O SpecificationsIncrement Mode 5 kHz Max SpecificationExpansion I/O Unit Input Specifications Relay Output CPU Unit and Expansion I/O Unit Output SpecificationsTransistor Output Source Type Transistor Output Sink Type20EDT 8ET 10CDT1-D 20CDT1-D 30CDT1-D 40CDT1-D 20EDT1 8ET1RS-232C Adapter Specifications Communications Adapter SpecificationsRS-422 Adapter Specifications CPU Unit Components Unit ComponentsCPM1A-10CDR-j/10CDT-D/10CDT1-D 10 I/O Terminals CPM1A-40CDR-j/40CDT-D/40CDT1-D 40 I/O TerminalsFatal error Input indicators Indicator Status MeaningCPU Unit Component Descriptions Expansion I/O Unit with 20 I/O Terminals Expansion I/O Unit ComponentsExpansion I/O Unit with 8 Input Terminals Expansion I/O Unit with 8 Output TerminalsAnalog I/O Unit Components Temperature Sensor Unit ComponentsCPM1A-TS101/102 CPM1A-TS001/002Set value Thermocouple Range C Range F Set value Platinum resistance Range C Range FCompoBus/S I/O Link Unit Components Pins FunctionRS-232C Adapter Communications Adapter ComponentsRS-422 Adapter Installation and Wiring Power Supply Wiring Design PrecautionsPower Supply Voltage 4 CPM1A Power InterruptionsInstallation Site Conditions Selecting an Installation SiteMomentary Power Failure Detection Automatic RestartOverheating Panel/Cabinet Installation2 CPM1A Installation Installing the CPM1A1 CPM1A Orientation CorrectDIN Track Installation Installation Connecting an Expansion I/O UnitRemoval Section General Precautions for Wiring Wiring and ConnectionsLine Noise Hanging DuctsFloor Ducts Ground WiringConduits GroundingTo 240-VAC Power Supply Crimp ConnectorsVDC Power Supply Input Configuration Input WiringCPM1A-8ED Outputs Input Wiring ExampleInput Devices Device Circuit diagramInductive Loads Relay Output Wiring Output WiringOutput Configurations CPM1A-8ER Transistor Output Wiring Sink Type CPM1A-8ET CPM1A-40CDT1-D Transistor Output Wiring Source TypeOutput Short Protection Polarity of Power Supply for the LoadFuse Insertion Inrush Current ConsiderationsHost Link Connections Peripheral Device ConnectionOne-to-one Host Link Connection One-to-N Host Link Connection RDB SDB RDA SDA One-to-one PC Link Connections One-to-one NT Link Connections C200HX/HG/HE PC Using Peripheral Devices 2 CPM1A Restrictions and Precautions SSS System SetupSupport Software Capabilities Online Editing Offline OperationsCopy Group Name Description Go ToFill PrintPC Setup File Time ChartGroup Name Description Utility Data Area Lists ChangeOnline Operations Offline and Online Operations Compatible Programming Consoles Using a Programming ConsoleCQM1-PRO01-E C200H-PRO27-EBuzzer Volume Mode SwitchDifferent Keys Contrast ControlProgram Mode Changing the CPM1A’s Mode with the Mode SwitchMonitor Mode RUN ModePanel Installation Connecting the Programming ConsolePreparation for Operation Entering the PasswordProgram Password Program BZ Overview Programming Console OperationsAll Clear Clearing MemoryPartial Clear Buzzer Operation Reading/Clearing Error MessagesKey Sequence OFF Entering or Editing Programs Writing a Word Address Writing Hexadecimal, BCD Constant#FFF6 Writing an Unsigned Decimal NumberWriting a Word Address DM Bit Operand Search Instruction SearchInsertion Inserting and Deleting Instructions00207INSERT END Not DeletionDelete END Checking the Program00178CIRCUIT ERR Corrected ProgramBit Monitor 11 Bit, Digit, Word MonitorCont Word MonitorChannel LR Multiple Address MonitoringCLR Channel LR Binary Monitor Differentiation Monitor@OFF OFF OFF CLR OFF OFF OFFThree-word Monitor Unsigned Decimal Monitor Signed Decimal MonitorThree-word Data Modification Changing Timer, Counter SV3CH CHG? Inputting a New SV Constant Hexadecimal, BCD Data ModificationIncrementing and Decrementing a Constant Pres VAL? Binary Data ModificationMontr D0000 Montr Signed Decimal Data ModificationUnsigned Decimal Data Modification Force Set, ResetHex-ASCII Display Change Clear Force Set/ResetOn on 00000FORCE RELE?Programming Example Program PasswordDisplaying the Cycle Time Preparatory Operations00000MEMORY CLR? HR CNT DM Montr END HR CNT DM Example Program Programming ProceduresInputting the One-second Timer Programming ProceduresInputting the Self-holding Bit Write NOPInputting the 10-count Counter Inputting the Two-second TimerInputting the Flicker Output LD notInputting the END001 Instruction Monitor BZ Test Run in Monitor ModeTest Runs and Error Processing 2 CPM1A Test Run Procedure Initial System Checks and Test Run ProcedureInitial System Checks Points to checkFlash Memory Precautions CPM1A Cycle ErrorFatal Errors Non-fatal ErrorsSelf-diagnosis Functions Message FAL No Meaning and appropriate responseUser-defined Errors Identifying ErrorsError Messages Error FlagsProgramming Errors Programming Console Operation ErrorsFALS07 Message MSG46Circuit ERR Type Message Meaning and appropriate responseMain Check Troubleshooting FlowchartsPower Supply Check Follow the Memory Error Fatal Error CheckNon-fatal Error Check 121 122 Environmental Conditions Check Memory Error Check Power supply Allowable voltage fluctuation range Maintenance InspectionsInspection Items Inspection items Details Criteria RemarksNecessary Tools for Inspection Handling PrecautionsStandard Tools Measurement DevicesExpansion Memory Unit Overview PrecautionsMemory Areas ButtonSpecifications Specifications and NomenclatureNomenclature Handling LED IndicatorMounting/Removing Eeprom Mounting EepromPC Connections Peripheral Port Communications SettingsCPM1, CPM1A, CPM2A CQM1, and SRM1 PCsUploading Programs DisconnectingDownloading Programs Operation Procedure134 135 Expansion Units Standard ModelsCPU Units Expansion I/O UnitsDescription Specifications Model number Temperature Sensor UnitsCompoBus/S I/O Link Unit Communications AdaptersPeripheral Devices Name Appearance Model Number SpecificationsCPM1A-10CDR-j/10CDT-D/10CDT1-D CPU Unit DimensionsCPM1A-20CDR-j/20CDT-D/20CDT1-D CPU Unit CPM1A-30CDR-j/30CDT-D/30CDT1-D CPU UnitCPM1A-20EDjExpansion I/O Unit CPM1A-40CDR-j/40CDT-D/40CDT1-D CPU UnitCPM1A-8jjjExpansion I/O Unit CPM1A-MAD01 Analog I/O Unit CPM1A-TSjjjTemperature Sensor UnitCPM1A-SRT21 CompoBus/S I/O Link Unit CPM1-CIF11 RS-422 Adapter CPM1-CIF01 RS-232C AdapterAppendix B Dimensions with Peripheral Devices AttachedAscii ACPAUTOEXEC.BAT BCDBit number Bit designatorBit-control instruction BlockCTS CONFIG.SYSDIP switch DefaultData link Data link areaEprom EepromFCS Initialization error DelayInput signal InstallLED JISLSS OFF NotPCB RAM PromRAS SCP ROMSSS System configuration Syntax errorSystem error System error messageWDT Numbers Index 165 166 167 Revision History Revision code Date Revised content
Related manuals
Manual 6 pages 62.26 Kb