Liebert
1000kVA
manual
Specifications
Error codes
Customer Alarm Interface
Inverter Fault
Maintenance
System Configuration Screens
Reporting a Problem
Manual Reset
Series 610 terminal commands
Timeout
Page 119
Page 118
Page 120
Image 119
Page 118
Page 120
Contents
Series 610 UPS
Battery Cabinet Precautions
Table of Contents
Specifications
Maintenance
Figures
Tables
Important Safety Instructions
Multi-Module UPS, 100-500kVA
System Description
Multi-Module UPS, 500-750kVA
Designed for Success
Reliability
Types of System Control Cabinets SCCs
Other Factors to Consider
Safety Precautions
Input Power Failure
Modes of Operation
Operator Controls
1989-2003
Options
Battery
Two Breaker Maintenance Bypass
Battery Racks or Cabinets
Module Battery Disconnect
Three Breaker Maintenance Bypass
System Control Cabinet
General Component Descriptions
UPS Module
Battery Plant
Software
Detailed Component Descriptions
Controls Hardware
Input Circuit Breaker
Input Power Factor
Rectifier/Charger
Operation
Battery Equalize Charge Circuit
Battery Charging Circuit
Battery Disconnect
Battery Charge Current Limiting
Output Regulation and Overload Performance
Non-Linear Load Characteristics
Unbalanced Load Characteristics
Inverter
Shorted SCR Monitoring
Static Bypass
Fuse Protection
Load Transfers
Static Switch Isolation
Pulsed Parallel Operation
Transfer and Retransfer Conditions
Retransfer Inhibited
Redundant Mode
Display Screen and Operator Controls
Features
Description Function
500kVA
1000kVA
Operation
Description Location Function
Refer to 3.4.5 Shutdown Procedures
Numbers are used as keys to data in , below
Switches behind SCC control panel door
Menu tree
Menu Tree Navigation
Module Master Menu
Master Menu Screen
SCC Master Menu
Operation
Output Metering Displays
SCC Monitor/Mimic Display Screen
Input Metering Displays
Item 6 System Status Messages
Status/Alarm Message Areas
Item 7 Alarm Messages
Item 5 Module Status Messages
Module Monitor/Mimic display screen
Module Monitor/Mimic Display Screen
Item 5 Alarm Messages
Alarm Messages
Module Display
SCC Display
Monitor/Mimic display example Utility fail
KVA / 217 kW 325A 325A 325A
MOD On Line OFF Line SUM ALM
B-C C-A 0V 0V Not OK to Transfer Static Switch Connected
Walk-in display screen during start-up
Walk-In Display Screen
Present Status
Status Reports Screens
Module Status Report
Event History
SCC Status Report
History status report screens
History Status
Alarm in SCC Alarm in Module
Alarm conditions that freeze history data gathering
System Status
Battery Cycle Monitor-Module Only
Battery cycle monitoring summary screen
SCC system configuration screen
System Configuration Screens
Date screen
Date
Time screen
Time
Auto Dial
Auto dial setting screen
Maximum Auto-Retransfer Attempts
Modem Baud Rate
Retransfer Attempts
System Current Rating
Language Selection
System Options
Continuous Duty Static Switch Optional
Battery test screen-MMU only
SCC and module remote monitor indications
Remote Monitor
Module alarm limit settings screen
Alarm Limit Settings Screen
Temperature Limit Setting Optional
Battery Float Voltage
Refer to 3.4.3 Load Transfer Procedures for more details
Load Transfer Procedures Screen
Refer to 3.4.1 SCC Start-Up Procedure for more details
Start-Up Procedures Screen
Module start- up procedures screens
Shutdown Procedures Screen
SCC shutdown procedures screen
Battery time screen 15 minute discharge
Battery Time Screen Module Only
Elapsed Time Minutes
Upper Limit Actual Lower Limit
Operation
Meter calibration screen
Meter Calibration Screen
Battery equalize screen
Battery Equalize Screen
System Status Messages
Alarm and Status Messages Module Status Messages
Abbreviation Definition
Abbreviations used in alarm messages
Load Block Messages
Alarm messages meaning and corrective action
Control Power
Manual Reset
Static Switch
Bypass Phase
Module N Off
Reverse Power
Inverter Fault
Transfer
New Alarm
Battery Overtemp
Overtemperature
Timeout
Special Functions
Alarm messages summary
Alarm Message
Requesting Information
Communication Interfaces
Worldwide Reporting
Auto-Dial
Site Reporting SiteScan or Snmp
Local Reporting to a Terminal
Local Reporting to a Monitor
Separate / Simultaneous Outputs
Series 610 terminal commands
Remote Monitor Panel
Circuit breaker abbreviations Abbreviation Circuit Breaker
OK to Transfer
Load on Bypass
Load on bypass, UPS available
Momentary Overloads
Momentary overload, pulsed static bypass switch
Input power fail-load on battery
Input Power Failure-Load on Battery
One module off-line, load on UPS
One Module Off-Line
Load on UPS-battery not available
Off Battery
Emergency Modules Off
Refer to 3.4.5 Shutdown Procedures
Emergency power off
Remote Emergency Power Off
System Shutdown
Refer to 3.3.10 Maintenance Bypass
Load on maintenance bypass, two breakers
Refer to 3.5 Automatic Operations for more details
Manual Procedures
SCC Start-Up Procedure
Operation
Operation
SCC start-up procedures screen
UPS Module Start-Up
Module start-up procedures screen
Operation
Manual Transfer Instructions UPS Lead
Load Transfer Procedures
If the load is on the UPS System Bypass
Maintenance Bypass Load Transfers
If the load is on Maintenance Bypass
Shutdown Procedures System Shutdown Procedure
Module Shutdown Procedure
Local Emergency Modules Off Lemo
Remote Emergency Power Off Repo
Automatic Operations
150%
Overloads Without Transfer
Automatic Transfers to Bypass
1000%
Automatic Emergency Modules Off
Automatic Retransfers to UPS
Automatic Module Off-Line
Maintenance
Training
Liebert Global Services
Maintenance Agreements The Signature Program
Professional Start-Up
Air Filters
Routine Maintenance
Record Log
Limited Life Components
Battery Safety Precautions
Battery Maintenance
Avertissement
Number of Cells Battery Voltage VDC Nominal Float
Matching Battery Cabinets Optional
Rack-Mounted Batteries
Battery retorque values
Battery voltage record
Torque Requirements
Torque specifications unless otherwise labeled
Detection of Trouble
Recommended Test Equipment
Reporting a Problem
Upstream Feeder Circuit Breaker Setting Inspections
Corrective Actions
KVA
Power factor pf KVA
Rating
Environmental Conditions
Specifications applicable to environment
Battery Operation
Adjustments
Electrical Specifications
Specifications 112
Page
United States
Technical Support/Service
Company Behind the Products
Locations
Related pages
Troubleshooting External Alarm Function for Honeywell DR4300
Technical Specifications for Extreme Networks 12800 Series
System error message, HDD controller failure, appears for Seagate 1270SL
TruSear Infrared Cooking Chart for Viking VGIQ5323RT1L
No numbers dialed when memory button is pressed for ClearSounds CSC600D
Installation on a Perpendicular Wall for Samsung LH75OMDPKBC/GO
Parts List for Boss Audio Systems GT580
Remote Control Operation/Code List for Panasonic TH-50PZ80Q
Selecting a Date in List by Date Mode for Nikon S1100pj
How do I replace parts in my
Wayne Dalton ProDrive 3220C
garage door opener?
Top
Page
Image
Contents