6: Tunnel Settings
Tunnel Accept Mode | Description |
Settings (continued) |
|
Flush Start Character | Enable or disable the flush start character: |
| Enabled = prevents forwarding of a start character from the Line into |
| the network. |
| Disabled = the flush start character allows forwarding of a start |
| character from the line into the network. |
| Note: This configuration option becomes available when Start Character |
| is the selected Mode. |
|
|
Flush Line | Set whether the serial line data buffer is flushed upon a new network |
| connection. Choices are: |
| Enabled = serial data buffer is flushed on network connection |
| Disabled = serial data buffer is not flushed on network connection |
| (default) |
|
|
Block Line | Set whether Block Line is enabled for debugging purposes. Choices are: |
| Enabled = if Enabled, incoming characters from the serial line will not |
| be forwarded to the network. Instead, they will be buffered and will |
| eventually flow off the serial line if hardware or software flow control is |
| configured. |
| Disabled = this is the default setting; incoming characters from the |
| Serial Line are sent into the network. Any buffered characters are sent |
| first. |
|
|
Block Network | Set whether Block Network is enabled for debugging purposes. Choices |
| are: |
| Enabled = if Enabled, incoming characters from the network will not be |
| forwarded to the Serial Line. Instead, they will be buffered and will |
| eventually flow off the network side. |
| Disabled = this is the default setting; incoming characters from the |
| network are sent on the Serial Line. Any buffered characters are sent |
| first. |
|
|
Password | Enter a password. This password can be up to 31 characters in length and |
| must contain only alphanumeric characters and punctuation. When set, |
| clients must send the correct password string to the unit within 30 seconds |
| from opening network connection in order to enable data transmission. |
| The password sent to the unit must be terminated with one of the following: |
| 0A (Line Feed) |
| 00 (Null) |
| 0D 0A (Carriage Return/Line Feed) |
| 0D 00 (Carriage Return/Null) |
| If, Prompt for Password is set to Enabled and a password is provided, |
| the user will be prompted for the password upon connection. |
|
|
To Configure Tunnel Accept Mode Settings
Using Web Manager
To configure the Accept Mode for a specific tunnel, click Tunnel in the menu and select Tunnel 1
Using CLI
To enter the Tunnel command level: config