Logicube Omniclone Xi user manual Buttons, Indicator Lights

Page 16

GETTING STARTED

2.Press and hold the Set button, then release the Reset button.

3.Hold the Set button until the unit boots to a screen that reads “Touchpad Calibration. Please touch square with finger (1/5)”.

4.Look for a square at the top of the screen. Touch the square when it is located.

5.Repeat the previous step four more times. The unit will count each time the square is pressed correctly. It will count (1/5), (2/5), etc.

6.Once the screen has been calibrated, it will reboot to the Main Menu Screen.

Buttons

The Omniclone Xi™ features two “Shortcut” buttons that are located to the right of the touch Screen. These buttons are available at all times.

START/STOP Button – Press it twice to begin a cloning operation using the current settings; press the START/STOP button in mid process to abort it. A single key stroke presents a preview screen where you can see the current setting, and decide whether to press it again to begin the capture, or back out to reconfigure.

SET Button – Press this button once to bring you to the settings screen where you can change capture modes and other settings of the unit.

Indicator Lights

The Omniclone Xi™ has indicator lights that are located on the User Interface panel as well as on the light bar. The lights are as follows:

The POWER indicator light is a red LED located to the right of the Touch Screen. It remains on while the Logicube Omniclone Xi™ is receiving power.

The STATUS indicator lights are located to the left of the Touch Screen as a series of green LED’s. Each Master and Target drive position has a corresponding Status indicator. These lights are lit during cloning operations and any operation that accesses the Master or Target drive. They will flash as data is transferred from one drive to the other.

The GREEN light on the light bar is also a general Status indicator light. It will blink during a cloning or diagnostic operation. In addition, if the unit completes an operation successfully the green light will stay lit.

10

Logicube Omniclone Xi ™ User’s Manual

Image 16
Contents Logicube, Inc Chatsworth, CA Phone 818 700 Fax 818 700 Version Date 2/20/06Warranty Limitation of Liability and Warranty InformationLogicube Disclaimer Table of Contents Omnidiagnostics Logicube Omniclone Xi Software Update Loading Software Through the Parallel PortPage Introduction to the Logicube Omniclone IntroductionFeatures IntroductionUsing this guide System descriptionIntroduction Logicube Omniclone Introduction Connecting Parallel IDE, EIDE, Udma Drives Applying power to the Logicube OmnicloneGetting Started Fast Start Connecting Serial ATA Sata Drives Connecting other types of drivesPower and Reset buttons User interfaceTouch Screen Calibrating the Touch ScreenIndicator Lights ButtonsInstalling and Removing the Light Bar Buttons and InterfaceCloning Modes and Settings Time/Date SettingsMain Menu Screen About ScreenCloning DrivesSelective Partitions Mode Optional Clever Clone ModeClever Clone Step-by-Step Selective Partitions Step-by-Step CleverCopy Mirror Clone Mode Mirror Clone Step-by-StepMaster Manager Mode Optional Master Manager Step-by-StepDell Optiplex Computers and Master Manager Verify Settings Optional Preference SettingsVerify Speed Geometry CHS Translation ModesGeneral Preferences On Error OptionalIntroduction On Error Step-by-Step Set OptionLast Drive Set Option Step-by-StepLast Drive Step-by-Step Database/Barcode Option Password Setting a Password Step-by-StepRemoving a Password DatabaseOmniDiagnostics Features OmniDiagnosticsScan Target Mode Scan Target Mode Step-by-Step Repair Target ModeRepair Target Mode Step-by-Step WipeClean Target ModeWipeClean Settings Wipeclean Target Step-by-StepOmnidiagnostics Database/Barcode Option System ContentsCompact Flash CF Files Breakdown of Config.txt Database.csv Database Step-by-Step Database Settings Menu Creating a New Config List, Step-by-Step Barcode Scanner Settings Barcode ScannerDATABASE/BARCODE Option Using the USB Port Minimum requirementsHow to use under Windows for Master Drive Management Removing USB devicesUsing the USB Port Compact Flash CF Card Connecting the CF Drive to Windows via USB Connecting Through the Software Setup MenuCompact Flash CF Card User Replaceable Hardware Drive CablesProper Handling of Drive Cables Removal and Installation of a Drive StationDrive Stations Power Supply Removal and Installation of the Power SupplyLoading Software Using the Compact Flash Logicube Omniclone Xi Software Updating ProceduresSoftware Loading Instructions Software Loading Instructions Host PC preparationLogicube Omniclone Xi Software Update Frequently Asked Questions and Answers FAQ’sFrequently Asked Questions and Answers Frequently Asked Questions and Answers Troubleshooting Guide Frequently Asked Questions and Answers Frequently Asked Questions and Answers Reference GlossaryCloning, Hard Drive ClusterReference DefragmentLarge Geometry, Hard DriveMaster Drive, Logicube Omniclone Parallel Port Master/Single Drive, IDEPartition Sector RAM DiskSlave Drive, IDE Translation Mode, CHS Target Drive, Logicube OmnicloneWiping, Data Index FdiskIndex Reference Index