Logicube Omniclone Xi user manual Database Settings Menu

Page 42

THE DATABASE/BARCODE OPTION

11. When the cloning Session is finished, the unit will write data to the database.csv file. If one or more “Scan” lines are in the Config List, then the User will be prompted to use the Barcode Scanner.

Fig 3. Barcode Scan Prompt

12. When prompted, aim the Barcode Scanner at the Barcode to be read. Hold the scanner at an angle about 6 – 8 inches from the barcode. Hold down the trigger until the Scanner beeps.

13. After the data is collected, the unit will stop with a “clone successful” message.

14. At this point the database.csv file can be copied from the CF drive and imported into the database program of your choice. Use USB Mode to gain access to your CF drive.

Database Settings Menu

The Logicube DataBase™ Menu is made up of six different settings:

Select Config – This setting allows the user to choose a Config List from the Config.txt file. A checkmark appears next to the selected list.

On the Config.txt file itself, the active list is denoted by an asterisk ( * ) located next to the list title.

Database Off/On – This setting tells the Omniclone-Xi to run the Database function during the next cloning session. It will continue to do so until the setting is turned off.

Printer Menu – This setting prints the collected data through a printer that is connected to the parallel port of the Omniclone-Xi™. When opened, this setting will prompt the user to enter the number of entries to be printed. For example, if 20 clones have been performed with the database turned on, the user can select any number of entries up to 20.

36

Logicube Omniclone Xi ™ User’s Manual

Image 42
Contents Logicube, Inc Chatsworth, CA Phone 818 700 Fax 818 700 Version Date 2/20/06Limitation of Liability and Warranty Information WarrantyLogicube Disclaimer Table of Contents Omnidiagnostics Logicube Omniclone Xi Software Update Loading Software Through the Parallel PortPage Introduction to the Logicube Omniclone IntroductionFeatures IntroductionUsing this guide System descriptionIntroduction Logicube Omniclone Introduction Applying power to the Logicube Omniclone Connecting Parallel IDE, EIDE, Udma DrivesGetting Started Fast Start Connecting Serial ATA Sata Drives Connecting other types of drivesTouch Screen Power and Reset buttonsUser interface Calibrating the Touch ScreenIndicator Lights ButtonsInstalling and Removing the Light Bar Buttons and InterfaceMain Menu Screen Cloning Modes and SettingsTime/Date Settings About ScreenCloning DrivesClever Clone Mode Selective Partitions Mode OptionalClever Clone Step-by-Step Selective Partitions Step-by-Step CleverCopy Mirror Clone Mode Mirror Clone Step-by-StepMaster Manager Mode Optional Master Manager Step-by-StepDell Optiplex Computers and Master Manager Optional Preference Settings Verify SettingsVerify Speed Geometry CHS Translation ModesOn Error Optional General PreferencesIntroduction On Error Step-by-Step Set OptionSet Option Step-by-Step Last DriveLast Drive Step-by-Step Removing a Password Database/Barcode Option PasswordSetting a Password Step-by-Step DatabaseOmniDiagnostics OmniDiagnostics FeaturesScan Target Mode Scan Target Mode Step-by-Step Repair Target ModeRepair Target Mode Step-by-Step WipeClean Target ModeWipeClean Settings Wipeclean Target Step-by-StepOmnidiagnostics System Contents Database/Barcode OptionCompact Flash CF Files Breakdown of Config.txt Database.csv Database Step-by-Step Database Settings Menu Creating a New Config List, Step-by-Step Barcode Scanner Settings Barcode ScannerDATABASE/BARCODE Option Using the USB Port Minimum requirementsHow to use under Windows for Master Drive Management Removing USB devicesUsing the USB Port Compact Flash CF Card Connecting the CF Drive to Windows via USB Connecting Through the Software Setup MenuCompact Flash CF Card User Replaceable Hardware Drive CablesRemoval and Installation of a Drive Station Proper Handling of Drive CablesDrive Stations Power Supply Removal and Installation of the Power SupplyLogicube Omniclone Xi Software Updating Procedures Loading Software Using the Compact FlashSoftware Loading Instructions Software Loading Instructions Host PC preparationLogicube Omniclone Xi Software Update Frequently Asked Questions and Answers FAQ’sFrequently Asked Questions and Answers Frequently Asked Questions and Answers Troubleshooting Guide Frequently Asked Questions and Answers Frequently Asked Questions and Answers Cloning, Hard Drive ReferenceGlossary ClusterReference DefragmentGeometry, Hard Drive LargeMaster Drive, Logicube Omniclone Master/Single Drive, IDE Parallel PortPartition RAM Disk SectorSlave Drive, IDE Target Drive, Logicube Omniclone Translation Mode, CHSWiping, Data Index FdiskIndex Reference Index