Tsunami MP.11 Installation and Management
VIEWING AND CHANGING PARAMETERS
You can view and change MP.11 parameters with the SHOW and SET commands, respectively. These commands are described below.
Show Command
The show command lets you view parameter and statistical values. You can view a single parameter, a group of parameters, or a table with parameters. A table consists of rows with similar parameters.
Example: To view all system parameters:
show system
This shows the current values of the system parameters.
Set Command
The set command lets you change parameter values. You can change a single parameter value and you can also modify a group of parameters, or a table with parameters. If a parameter requires more than one value, the values must be separated by spaces.
Example: To set the MP.11 IP address parameter:
set ipaddrtype static
set ipaddr 1 ipaddress 10.0.0.12
Some parameter values change only when the MP.11 is rebooted. In these cases, the CLI warns you that a reboot is required for the change to take effect.
ENTERING STRINGS
If you need to enter a string with spaces, you must use single or double quotes. For example, there is no need for quotes in the following because the string does not contain spaces:
set sysname Lobby
The following string, however, requires quotes because of the space between the words Front and Lobby.
set sysname “Front Lobby”
Chapter 6. Command Line Interface | 61 |
CPN 63708 | Issue Date: 02/05/2003 |