Tsunami MP.11 Installation and Management
Setup and Configuration
Ethernet Link does not work
First check the Ethernet LED;
▪Dim is “no media connected.”
▪Green and steady is 10
▪Amber and steady is 100
▪Blinking Green or Amber is traffic
Verify
Cannot use the Web Interface:
1.Open a command prompt window and enter ping <ip address MP.11> (for example ping 10.0.0.1). If the MP.11 does not respond, make sure that you have the correct IP address.
If the MP.11 responds, the Ethernet connection is working properly, continue with this procedure.
2.Ensure that you are using one of the following Web browsers:
ºMicrosoft Internet Explorer version 5.0 or later.
ºNetscape version 6.0 or later.
3.Ensure that you are not using a proxy server for the connection with your Web browser.
4.Ensure that you have not exceeded the maximum number of Web Interface or CLI sessions (with the CLI command show pelsessions).
5.
6.Perform network infrastructure troubleshooting (check switches, routers, and so on).
Chapter 9. Troubleshooting | 77 |
CPN 63708 | Issue Date: 02/05/2003 |