APC VS 50, VS 100 user manual Introduction, General Information, How to Use This Manual

Page 7

2 Introduction

2.1. General Information

DC Power Plants from APC have unique features that make them easy to install, maintain, and upgrade. The rectifier units are modular and truly “hot-pluggable” into the shelf assembly without any separate ac wiring. The Magnum VS 50 has 1 shelf, holding up to five rectifiers for a rated current of 50 A. The Magnum VS 100 has 2 shelves, holding up to ten rectifiers for a rated current of 100 A. All system settings are made from a standard PC using a serial cable or a 10/100 Base T connection. The controller provides monitoring and control functions for each component of the system and stores alarm listings for system diagnosis and maintenance. For ease of operation, a display with LCD readout and 5-button keypad can be inserted in rectifier slot 5

Figure 2.1-1 Magnum VS 50 –48 Vdc Power Plant

The APC Magnum VS is a modular stand-alone -48 Vdc power plant. It is configurable in such a manner that it will support most typical applications within the specified current ranges (10-100

A)without special application engineering or assistance. DC output distribution is included for circuit breakers or GMT style fuses or in the 100-A versions, a combination of both. Available circuit breakers are 30 A or 60 A. GMT fuses can be 1/4 to15 A. A low voltage disconnect (LVD) is provided to disconnect the battery after deep discharge. A 50-ampere power system is shown in Figure 2.1-1. A block diagram of a typical 100-ampere power system with fuses and breakers is shown in Figure 2.2-1.

2.2. How to Use This Manual

Each section of this manual can be read in any order and provides a complete explanation of the subject described by the title. However, the sequence of the sections is designed to provide a typical step-by-step process for successful use of the equipment.

Magnum VS –48 Vdc User’s Manual

Page 2

Image 7
Contents Magnum VS Vdc Power Systems User’s Manual Table of Contents Final Inspection TWF0500H54B Rectifier Magnum VS Controller Document # & Rev Date Description Revision HistoryGeneral Precautions Safety FirstIntroduction How to Use This ManualGeneral Information Amp System Only Room / Location InstallationMechanical Installation Unpacking EquipmentVentilation AC Power ConnectionsAC Connections AWG AC Power Cord SetsPlanning the Battery installation Battery ConnectionsConnecting the Cables 1 Battery Cable Connection Locations Battery Temperature Probe InstallationDC System Grounding Counter Electro-Motive Force Cemf Cell ConnectionsCircuit Breaker Installation Load Protection InstallationGMT Fuse Installation GMT Fuse protected Load Connections Load ConnectionsCable Size Considerations Circuit Breaker Protected Load Connections 30 or 60 aMajor, Minor and Relay 1 Output Connections RJ45 Ethernet ConnectorMonitoring and Relay Output Connections Front Panel DB9 ConnectionRelay Terminal Relay Alias Output Relay Notes Designations Output Relay 2-6 ConnectionsExternal Alarm Input Connections Rectifier Module InstallationController Module Installation Pre-Commissioning Inspection Electrical InstallationBattery Visual and Safety Inspection CommissioningInitial Set-up AC Power UpDC Power Up CommissioningCircuit Breaker/ Fuse Test Battery Power UpRectifier Test LVD TestFinal Inspection Battery Temperature CompensationOutput Relay Rectifier Management Technical DescriptionSystem Management Circuit Breakers System Status and Alarm ReportingLoad Management System Current MonitorBattery Charging Battery ManagementGMT Fuses Battery Protection Battery EqualizationBattery Temperature Monitoring Battery Functional Test Battery Low Voltage DisconnectCounter Electro-Motive Force Module Connections Controller without Display Controls and IndicatorsAlarm Outputs Output Relays Controller with DisplayNetwork Management Card Local & Remote Monitoring External Alarm Inputs User InputDescription OperationController Card Jumpers J12 J13 Controller with Display1 Controller with Display Operation using Local Display and Keypad Interface设置 / 电池 / 容量 设置 / 系统 / 时/日 均充 / 均充时间 状态 / 系统 /参数 Alarms 均充时间 Controller without Display Operation Using the RS-232 Comm PortOperation Using the 10/100 BaseT Ethernet Port 1 Parameter Locations, Descriptions, and Settings ON, OFF Power Modules/Rectifiers Seconds Disable Output Relay System/Preferences LVD OperationProgramming Output Relays Page Inspection Preventive MaintenanceSystem Visual and Safety Inspection EquipmentRectifier Current Share Test Rectifier Alarm TestTest System Voltage TestBattery Current Test System Temperature TestBattery Temperature Test Battery Preventive Maintenance Procedure Alarm Summary System LT Alm System Temperature is below Minor TWF0500H54B Rectifier SpecificationsMagnum VS 50 Power System AC InputDC Output Magnum VS 100 Power SystemMagnum VS 50 Power System Magnum VS Controller MechanicalEnvironmental EMC ComplianceAPC Worldwide Customer Support Limited Product Warranty