Troubleshooting a Nonredundant Power Supply
Problem
•Power indicator on the front panel does not light
•Systems management software issues a power
•No power to the system
Action
CAUTION: Before you perform this procedure, see "Safety
CAUTION: See "Protecting Against Electrostatic Discharge" in the safety instructions in your System Information Guide.
1.Ensure that all power cables are properly connected to the system and any attached peripherals and to the electrical outlet (see "External Connections").
2.Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
3.Remove the cover (see "Removing the Cover").
4.Lay the system on its right side.
5.Ensure that the power cables are properly connected to the power connectors on the system board.
To identify system board connectors, see Figure
6.Stand the system upright.
7.Install the cover (see "Installing the Cover").
8.Reconnect the system to its electrical outlet and turn the system on, including any attached peripherals.
If the problem persists, see "Getting Help."
Troubleshooting System Cooling
Problem
•A fan is not operating properly
•System message indicates a problem with cooling
•Systems management software issues a
•
Action
CAUTION: Before you perform this procedure, see "Safety
CAUTION: See "Protecting Against Electrostatic Discharge" in the safety instructions in your System Information Guide.
1.Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.
2.Remove the cover (see "Removing the Cover").
3.Lay the system on its right side.
4.Ensure that the fan cables are properly connected to the fan connectors on the system board.
To identify system board connectors, see Figure
5.Ensure that