Dell 1600SC Microprocessors, Removing Memory Modules, Removing and Installing a Microprocessor

Page 72

Removing Memory Modules

CAUTION: Before you perform this procedure, see "Safety First—For You and Your System" in "Troubleshooting Your System."

CAUTION: See "Protecting Against Electrostatic Discharge" in the safety instructions in your System Information Guide.

1.Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2.Remove the cover (see "Removing the Cover" in "Troubleshooting Your System").

3.Lay the system on its right side.

4.Locate the memory module connectors from which you will remove memory modules (see Figure A-3).

5.Press down and outward on the memory module connector ejectors until the memory module pops out of the connector (see Figure 6-4).

6.Repeat step 4 and step 5 of this procedure to remove any other memory modules.

7.Perform step 5 through step 10 of "Performing a Memory Upgrade."

Microprocessors

To take advantage of future options in speed and functionality, you can add a second microprocessor or replace either the primary or secondary microprocessor.

NOTE: The second microprocessor must be of the same type as the first. If the two microprocessors are different speeds, both will operate at the speed of the slower microprocessor.

Each microprocessor and its associated cache memory are contained in a PGA package that is installed in a ZIF socket on the system board.

The following items are included in the microprocessor upgrade kit:

A microprocessor

A heat sink with cooling fan

Removing and Installing a Microprocessor

CAUTION: Before you perform this procedure, see "Safety First—For You and Your System" in "Troubleshooting Your System."

CAUTION: See "Protecting Against Electrostatic Discharge" in the safety instructions in your System Information Guide.

1.Turn off the system, including any attached peripherals, and disconnect the system from the electrical outlet.

2.Remove the cover (see "Removing the Cover" in "Troubleshooting Your System").

3.Lay the system on its right side.

4.If you are removing or installing a microprocessor in socket CPU2, remove the vertical plastic baffle to improve access to the microprocessor socket (see "Removing the Baffle" in "Troubleshooting Your System").

5.Disconnect the microprocessor fan cable from the fan power connector on the system board (see Figure 6-5).

To identify system board connectors, see Figure A-3.

6.Remove the back system fan (see "Removing the Back System Fan").

CAUTION: The microprocessor and heat sink can become extremely hot. Be sure they have had sufficient time to cool before handling.

NOTICE: Do not operate the system without the fan and heat sink assembly installed. The assembly is required to maintain proper thermal conditions.

NOTICE: After removing the fan and heat sink assembly, place it upside down on a flat surface to prevent the thermal interface material on the heat sink from being damaged or contaminated.

NOTICE: The microprocessor fan and heat sink are constructed together as a single assembly. Do not attempt to remove the fan from the heat sink.

Image 72
Contents Initial release 22 Sep Jumpers, Switches, and Connectors Jumpers-A General ExplanationSystem Board Jumpers JumpersSystem Board Connectors Table A-1. System Board Jumper SettingsJumper Setting Description Disabling a Forgotten Password Table A-2. System Board ConnectorsConnector Description Back to Contents Ports and Connectors ConnectorsTable B-1. I/O Connector Icons Icon ConnectorSerial Connector Parallel ConnectorSerial Connector Autoconfiguration Pin Signal DefinitionPS/2-Compatible Keyboard and Mouse Connectors Table B-3. Parallel Connector Pin Assignments18-25 Video Connector USB ConnectorIntegrated NIC Connector Pin Signal I/O DefinitionNetwork Cable Requirements Abbreviations and Acronyms CGA Dimm EMI GUI LAN MBR Ntfs Pqfp SBE UMB ZIF Introduction Other Documents You May NeedObtaining Technical Assistance Indicators, Codes, and Messages Front-Panel FeaturesBack-Panel Features Component DescriptionPower Indicator Codes Power Button IndicatorsIndicator Function Hard-Drive Indicator Codes NIC Indicator CodesHard-Drive Status Indicator Codes Drive-Status Indicator Indicator CodeNIC Indicator Codes Indicator Indicator CodeSystem Messages System MessagesDiskette Drive, Troubleshooting a CD Drive, Troubleshooting Guide System Beep Codes System Beep Codes Code Cause Corrective ActionDiagnostics Messages Alert MessagesFinding Software Solutions Troubleshooting Errors and ConflictsInput Errors Before You BeginIRQ Assignment Defaults Application ConflictsIRQ Assignment Conflicts IRQ Line AssignmentRunning the System Diagnostics Running Server Administrator DiagnosticsFeatures of the System Diagnostics When to Use the System DiagnosticsUsing the System Diagnostics Using the Device Groups Menu Error MessagesTroubleshooting Your System Safety First-For You and Your SystemChecking Specific System Problems External ConnectionsStart-Up Routine System OrientationStart-Up Routine Indications Look/listen for ActionBezel Removing the BezelInstalling the Bezel Installing the CoverSystem Cover BaffleInstalling the Baffle Troubleshooting the Video SubsystemChecking the Equipment Removing the BaffleTroubleshooting the Keyboard Troubleshooting the MouseTroubleshooting the Basic I/O Functions Troubleshooting a Serial I/O DeviceTroubleshooting a Parallel Printer Troubleshooting a USB DeviceTroubleshooting a NIC Inside the SystemTroubleshooting a Wet System Responding to a Systems Management Alert MessageTroubleshooting a Damaged System Troubleshooting the System BatteryTroubleshooting Redundant Power Supplies Troubleshooting a Nonredundant Power Supply Troubleshooting System CoolingTroubleshooting Expansion Cards Troubleshooting System Memory Troubleshooting the Diskette Drive Troubleshooting a CD Drive Troubleshooting a Tape Drive Troubleshooting an IDE Tape DriveTroubleshooting a Scsi Tape Drive Troubleshooting Hard Drives Troubleshooting an IDE Hard DriveTroubleshooting an IDE Hard Drive in a RAID Configuration Troubleshooting a Scsi Hard Drive System With Scsi BackplaneHard-drive cables Device drivers Troubleshooting a RAID Controller Card Troubleshooting a MicroprocessorTroubleshooting the System Board Resetting Corrupted Bios Configuration Back to Contents Installing System Options System FansRemoving the Front System Fan Installing the Front System Fan Installing the Back System FanRemoving the Back System Fan Redundant Power Supplies Removing a Redundant Power SupplyInstalling a Redundant Power Supply Installing an Expansion Card Expansion CardsRemoving and Installing an Expansion Card Removing an Expansion CardMemory Upgrade Kits Memory Module Installation GuidelinesPerforming a Memory Upgrade Sample Memory Module ConfigurationsInstalling Memory Modules Removing and Installing a Memory ModuleRemoving and Installing a Microprocessor MicroprocessorsRemoving Memory Modules Removing the Microprocessor Fan and Heat Sink Assembly System Battery Replacing the System BatteryReplacing the System Battery Installing Drives Connecting DrivesDrive Cable Configurations DC Power CablesIDE Configuration Information Scsi Configuration InformationScsi Interface Cables Scsi ID NumbersConfiguring the Boot Drive Installing a Diskette DriveDiskette Drive Removing a Diskette DriveFront-Panel Drive Inserts Removing the Front-Panel Drive InsertsInstalling the Front-Panel Drive Inserts Installing a 5.25-Inch DriveInch Drives Page General Installation Guidelines Hard DrivesInstalling and Removing Non-Hot-Plug Hard Drives Removing and Installing a Non-Hot-Plug Hard DriveInstalling a Non-Hot-Plug Hard Drive Page Installing and Removing Hot-Plug Scsi Hard Drives Removing a Hot-Plug Hard Drive Installing a RAID Controller Card Installing a Hot-Plug Hard DriveBack to Contents Online Services Getting HelpTechnical Assistance AutoTech Service Automated Order-Status ServiceTechnical Support Service Ftp.dell.comBefore You Call Diagnostics Checklist Contacting DellAntigua and Barbuda Argentina Buenos AiresAustralia Sydney 0011Austria Vienna Website support.euro.dell.com 900Colombia Costa RicaCzech Republic Prague Website support.euro.dell.com Denmark Copenhagen Website support.euro.dell.comGermany Langen Website support.euro.dell.com Greece Website support.euro.dell.comGrenada GuatemalaKorea Seoul Latin AmericaLuxembourg Website support.euro.dell.com MacaoNew Zealand NicaraguaNorway Lysaker Website support.euro.dell.com PanamaGrenadines Singapore Singapore 005South Africa Johannesburg Website support.euro.dell.com 09/091Trinidad/Tobago Turks and Caicos IslandsBracknell Website support.euro.dell.com Uruguay