Sterling 882.00255.00 CV3-655 specifications Pump, 128-Station Controller Configurable Settings

Page 68

Name

Description

Options

Default

Every n loads

Number of conveying cycles between filter

1–99

5

 

cleanings.

 

 

 

Adjust this setting based on experience. The

 

 

 

more dust and debris in your material line, the

 

 

 

smaller this number needs to be.

 

 

# pulses

Number of pulses of compressed air sent

1–99

5

 

through the station’s filter during cleaning.

 

 

 

If blowback is not working as desired, the

 

 

 

service department may ask you to change this

 

 

 

setting.

 

 

On time

Number of seconds that the each air pulse lasts

0.1–99.9 sec.

1.0 sec.

 

during filter cleaning.

 

 

 

If blowback is not working as desired, the

 

 

 

service department may ask you to change this

 

 

 

setting.

 

 

Off time

Number of seconds between air pulses during

0.1–99.9 sec.

1.0 sec.

 

filter cleaning.

 

 

 

If blowback is not working as desired, the

 

 

 

service department may ask you to change this

 

 

 

setting.

 

 

Slide gate

When this option is enabled, the controller

disabled,

disabled

 

opens the slide gate between the station and

enabled

 

 

the receiver during the dump delay and during

 

 

 

blowback.

 

 

 

Enable this option if and only if the station has a

 

 

 

slide gate instead of a flapper and demand

 

 

 

switch.

 

 

Purge

When enabled, this option allows the system to

disabled,

disabled

 

empty the material line completely after every

enabled

 

 

convey to this station. The station’s pump

 

 

 

continues to draw without picking up material for

 

 

 

an extra period of time after conveying is

 

 

 

finished.

 

 

 

Enable this option if and only if you are using a

 

 

 

purge valve for this station. This option cannot

 

 

 

be used with a volume-fill station.

 

 

Purge duration

Number of seconds allowed for purging. The

0–999 sec.

20 sec.

 

station’s vacuum valve remains open for the

 

 

 

convey time plus this time.

 

 

 

Adjust this setting to the amount of time

 

 

 

required for material to travel from the pickup

 

 

 

point (purge valve) to the station.

 

 

Purge valve

Number (address) for the purge valve used with

1–154

0 (= not

 

this station.

 

assigned)

 

Set this to match the number (address) for the

 

 

 

purge valve that services this station. If another

 

 

 

station has the purge valve that services this

 

 

 

station, enter the number of that station (range:

 

 

 

1–50). If a central purge valve services this

 

 

 

station, enter the number (address) of that valve

 

 

 

(range: 51–154).

 

 

Material set to n

Number for the material line that should be

0 –150

0 (= not

 

connected to this station.

 

assigned)

24-Pump, 128-Station Controller

Chapter 6: Configurable Settings

67

Image 68
Contents SCC 24-Pump 128-Station Controller Parts and Service Department Shipping Information Table of Contents Maintenance Safety Symbols Used in this Manual SafetyHow to Use This Manual Wear Safety Glasses and Work Gloves Operator Responsibility ResponsibilityGeneral Responsibility Maintenance Responsibility Reporting a Safety DefectStandard Features Mechanical FeaturesFunctional Description Models Covered in This ManualOptional Features Safety Devices and InterlocksElectrical Features Controller FeaturesFail Safe Operation Safety Circuit StandardsSafety Device Lock-Outs Installation System Installation OverviewUncrating Mounting the Control PanelMaking Control Panel Power Drop Wiring Connections Installing KwikLink CableElectrical Connections Running KwikLink CablesSetting Up and Installing Mounting Plates Setting Up Mounting PlatesInstalling Assembled Mounting Plates Terminating Cable RunsInstalling Inside KwikLink Connectors with Blank Caps Discard the standard resistor cap to eliminate confusionArmorBlock Address Ranges Addressing and Installing ArmorBlocksAddressing ArmorBlocks Setting ArmorBlock Addresses Using seal block to pierce cable Installing KwikLink Connectors Connecting the Controller to the Network Connecting the Remote Interface to the Main ControllerPage Connecting the Power Supply Enclosure to the Network Proper Controller and Remote Interface ConnectionsPage Proper Power Supply Enclosure Connections Connecting Vacuum Receivers to the Network24/128 8-Connector ArmorBlock Connections Proper Vacuum Receiver Connections Connecting Vacuum Pumps and Filter Chambers to the Network Connecting Vacuum PumpsProper Vacuum Pump Connections, Standard XPD/XPC Pumps Proper Vacuum Pump Connections, Xpdb Pump Connecting Filter Chambers Proper Filter Chamber Connections, Blowback Proper Filter Chamber Connections, Implosion Type Connecting Central Alarms to the Network Proper Central Alarm Connections Setup Connector ArmorBlock Connections for Central AlarmsSetting Up the System Setting the Number of Stations and the Number of PumpsNaming Purge Valves and Materials Setting the Date/TimeChecking Addressing and Wiring for System Components Setting Up Alarm Silences Alarm Horn Silence Setting Up Pump StagingSetting Up Stations Setting Up a Single StationNaming Stations Copying Settings from One Station to Others To copy the selected station’s settings to one other stationSetting Up Pumps Setting Up a Single PumpPage Copying Settings from One Pump to Others Naming PumpsTo copy the selected pump’s settings to one other pump To copy the current pump’s settings to all other pumpsFinishing Setup Setting Up Passwords Password Duration Save/Restore SettingsInitial Startup Starting and Stopping the System OperationOverview Basic Tasks Reviewing Station StatusReviewing Pump Status Color Label DescriptionLogging On and Logging Off Enter the alphanumeric password Enabling and Disabling Stations and PumpsNavigating among the Station Operator Screens Reviewing and Adjusting Basic Station SettingsReaching and Reading the Station Operator Screens Adjusting Convey Time and Dump Delay Activating and Stopping Priority Convey for a StationChanging the Mixture for a Remote Proportioning Valve Transferring Stations to a Standby Pump Reviewing and Resetting a Pump Hour MeterAdvanced Tasks Page Page Silencing Alarms AlarmsReviewing Alarms Maintenance Preventative MaintenanceCorrective Maintenance Network Scanner Module ConsiderationsMemory Module Considerations Configurable SettingsOptions for Station Setup Name Description Options Default Conveying Options Option Input Pump, 128-Station Controller Configurable Settings Pump, 128-Station Controller Configurable Settings Options for Pump Setup Pump, 128-Station Controller Configurable Settings Troubleshooting General TroubleshootingStation Alarms Alarm message Possible causePump, 128-Station Controller Troubleshooting Pump Alarms System AlarmsOptional Components WarrantyAppendix Drawings and Diagrams 24-Pump, 128-Station Controller with 10 DisplaySpare Parts List Typical System Installation LayoutCredit Returns Warranty ReturnsReturned Material Policy Controller Identification Serial Number Tag Safety Tag InformationController Safety Tags Service Department Technical Assistance Contact InformationParts Department Sales Department