Sterling 882.00255.00 CV3-655 specifications Reviewing and Adjusting Basic Station Settings

Page 57

Reviewing and Adjusting Basic Station Settings

Reaching and Reading the Station Operator Screens

The 24/128 Controller has a Station Operator Settings screen for each station, as shown below. This screen enables you to review and adjust all basic settings for the station.

To reach the Station n Operator screen:

1.Go to the Station Status screen, if needed.

To reach this screen from any other screen, touch Stations on the right-hand side of the screen.

2.Touch and hold the icon for the station, until the controller either prompts for the password or displays the Station n Operator screen.

Once you have entered the password (if needed), the Station n Operator screen appears:

Settings in the box labeled Convey, the red Priority Convey Activate button, and the menu controls on the right-hand side of the screen appear for all stations. The other options in this screen appear if and only if the station has these features enabled.

Buttons in light gray are settings that you can adjust at this screen. Boxes in dark gray are for display only. If a pump assignment or purge setting needs to be changed, this must be done at the Station n Setup screen.

Navigating among the Station Operator Screens

The controls in the upper right-hand corner of the screen enable you to move among the Station Operator screens:

1.To display the screen for the next lower-numbered station (for example, to move from the screen for Station 15 to the screen for Station 14), touch ◄ Back.

2.To display the screen for the next higher-numbered station (for example, to move from the screen for Station 15 to the screen for Station 16), touch Next ►.

3.To display the screen for a specific station, touch Goto. A keypad pops up. Enter the number for the desired station. Use ← to erase any mistakes. Use ↵ to enter the value.

4.To exit to the Station Status (or Pump Status) screen, touch Stations (or Pumps).

24-Pump, 128-Station Controller

Chapter 4: Operation

56

Image 57
Contents SCC 24-Pump 128-Station Controller Parts and Service Department Shipping Information Table of Contents Maintenance Safety How to Use This ManualSafety Symbols Used in this Manual Wear Safety Glasses and Work Gloves Responsibility General ResponsibilityOperator Responsibility Reporting a Safety Defect Maintenance ResponsibilityMechanical Features Standard FeaturesFunctional Description Models Covered in This ManualSafety Devices and Interlocks Optional FeaturesElectrical Features Controller FeaturesSafety Circuit Standards Safety Device Lock-OutsFail Safe Operation System Installation Overview InstallationUncrating Mounting the Control PanelInstalling KwikLink Cable Making Control Panel Power Drop Wiring ConnectionsElectrical Connections Running KwikLink CablesSetting Up Mounting Plates Setting Up and Installing Mounting PlatesTerminating Cable Runs Installing Assembled Mounting PlatesDiscard the standard resistor cap to eliminate confusion Installing Inside KwikLink Connectors with Blank CapsAddressing and Installing ArmorBlocks Addressing ArmorBlocksArmorBlock Address Ranges Setting ArmorBlock Addresses Using seal block to pierce cable Installing KwikLink Connectors Connecting the Remote Interface to the Main Controller Connecting the Controller to the NetworkPage Proper Controller and Remote Interface Connections Connecting the Power Supply Enclosure to the NetworkPage Connecting Vacuum Receivers to the Network Proper Power Supply Enclosure Connections24/128 8-Connector ArmorBlock Connections Proper Vacuum Receiver Connections Connecting Vacuum Pumps Connecting Vacuum Pumps and Filter Chambers to the NetworkProper Vacuum Pump Connections, Standard XPD/XPC Pumps Proper Vacuum Pump Connections, Xpdb Pump Connecting Filter Chambers Proper Filter Chamber Connections, Blowback Proper Filter Chamber Connections, Implosion Type Connecting Central Alarms to the Network Proper Central Alarm Connections Connector ArmorBlock Connections for Central Alarms SetupSetting the Number of Stations and the Number of Pumps Setting Up the SystemSetting the Date/Time Checking Addressing and Wiring for System ComponentsNaming Purge Valves and Materials Setting Up Alarm Silences Setting Up Pump Staging Alarm Horn SilenceSetting Up a Single Station Setting Up StationsNaming Stations To copy the selected station’s settings to one other station Copying Settings from One Station to OthersSetting Up a Single Pump Setting Up PumpsPage Naming Pumps Copying Settings from One Pump to OthersTo copy the current pump’s settings to all other pumps To copy the selected pump’s settings to one other pumpFinishing Setup Setting Up Passwords Save/Restore Settings Password DurationInitial Startup Operation OverviewStarting and Stopping the System Reviewing Station Status Basic TasksColor Label Description Reviewing Pump StatusLogging On and Logging Off Enabling and Disabling Stations and Pumps Enter the alphanumeric passwordReviewing and Adjusting Basic Station Settings Reaching and Reading the Station Operator ScreensNavigating among the Station Operator Screens Activating and Stopping Priority Convey for a Station Adjusting Convey Time and Dump DelayChanging the Mixture for a Remote Proportioning Valve Reviewing and Resetting a Pump Hour Meter Advanced TasksTransferring Stations to a Standby Pump Page Page Alarms Reviewing AlarmsSilencing Alarms Preventative Maintenance MaintenanceCorrective Maintenance Network Scanner Module ConsiderationsConfigurable Settings Options for Station SetupMemory Module Considerations Name Description Options Default Conveying Options Option Input Pump, 128-Station Controller Configurable Settings Pump, 128-Station Controller Configurable Settings Options for Pump Setup Pump, 128-Station Controller Configurable Settings General Troubleshooting TroubleshootingAlarm message Possible cause Station AlarmsPump, 128-Station Controller Troubleshooting System Alarms Pump AlarmsWarranty AppendixOptional Components 24-Pump, 128-Station Controller with 10 Display Drawings and DiagramsTypical System Installation Layout Spare Parts ListWarranty Returns Returned Material PolicyCredit Returns Safety Tag Information Controller Safety TagsController Identification Serial Number Tag Technical Assistance Contact Information Service DepartmentParts Department Sales Department