GTO RB923 rev Technical Specifications, GTO/PRO 2000 Series Swing Gate Operators

Page 11

Technical Specifications

GTO/PRO 2000 Series Swing Gate Operators

DRIVE

Low friction screw drive (linear actuator).

Temperature rating of motor -30 ºF (-34 ºC) to +160 ºF (71ºC).

Powered by a 12 Vdc motor; generates 650 ft. lb. of torque at 12 V.

110o degree opening time approximately 15 to 20 s.

Maximum push-pull tube stroke 24”.

Operator length with push-pull tube fully retracted is 39” (99 cm), mounting point to mounting point.

Limit switches are internal.

POWER

System is powered by a 12 Vdc, 7.0 Ah, sealed, rechargeable battery.

Battery charge maintained by 120 Vac, 60 Hz input and 18 Vac at 40 VA (2.9 A) output; transformer rectified to 14.5 Vdc through the GTO Control Board. Control board fuses (2) are rated for 15 A.

NOTE: DO NOT connect transformer directly to any battery. Do not replace fuses with higher ampere rated fuses; doing so will void your warranty and may damage your control board.

Battery charge maintained by GTO Solar Panel Charger: float voltage 14.5 Vdc output from

193/8" x 151/4" silicon alloy panel; generates minimum of 10 W at 600 mA. Gated diode on control

board prevents battery discharge.

CONTROL

GTO microprocessor-based control board is set for single leaf, pull-to-open gate installations. DIP switches can be adjusted to accommodate an optional kit for push-to-open gates (see Accessory Catalog).

Control board has temperature compensated circuits.

A circuit on the control board regulates charging. "Sleep draw" is 40 mA; "active draw" is 2 to 5 A.

Auto-memorization of digital transmitter code.

GTO remote-mounted RF receiver tuned to 318 MHz.

adjustable auto-close timer (OFF to 120 s), inertia, and obstruction sensitivity using three (3) potentiometers.

Power terminal bock accommodates a transformer and solar panels.

DIP switches simplify setup of gate operator.

Accessory terminal block fully compatible with push button controls, digital keypads, safety loops, card readers, etc.

Control board allows connection of safety edge sensors and photoelectric sensors.

Audio entrapment alarm sounds if unit encounters an obstruction twice while opening or closing.

OPERATIONAL CAPACITY

The GTO/PRO 2000 series will move gates weighing up to 1000 lb. (453 kg) and up to 20 ft. (6.1 m) in length provided all installation procedures have been followed. Ball bearing hinges should be used on all gates weighing over 250 lb. (113.4 kg).

Gate Weight

Gate Capacity Chart (estimated number of cycles based on use with a transformer)

1000 lb.

160

150

140

130

120

110

100

800 lb.

170

160

150

140

130

120

110

600 lb.

180

170

160

150

140

130

120

400 lb.

190

180

170

160

150

140

130

200 lb.

200

190

180

170

160

150

140

 

6-8 ft.

10 ft.

12 ft.

14 ft.

16 ft.

18 ft.

20 ft.

Gate Length

The GTO/PRO 2000 series operators are capable of continuous duty cycling. For questions about specific applications and information regarding cycling duty when charged by solar panels, call the GTO service department at (800) 543-GATE [4283] or (850) 575-0176.

These Specifications are subject to change without notice.

8

Image 11
Contents Series Converting Temperature Table of Contents Disconnecting the Operator Important Safety InstructionsII. During Installation Before InstallationIII. After Installation Secondary Means of Protection Against Entrapment Entrapment Alarm UL 325 30A.1.1ANo ONE should Cross the Path of the Moving Gate Consumer/End UserEntrapment Protection Required Safety Precautions for Swing GatesInstall Warning Signs Moving Gate Can Cause Injury Or Death GTO/PRO 2000 Series Swing Gate Operators Technical SpecificationsHardware not to scale PartsControl Box and Electrical Components Single Gate Operator Parts ListStep Preparing the GatePull-to-Open Single Gate gate opens into the property Installing The Post Bracket Assembly Step Enough for the operator to pivot Connecting Operator to Post Bracket Assembly1/ nut. Note when tightening Rear mount bolt, leave it looseInstalling the Gate Bracket Installing the Open and Closed Position Stops Mounting the Control Box Battery Never insert the battery with the terminals to the rightGate Length Powering the SystemEstimated Maximum Number of Cycles Per Day Splice wires togetherSolar Zones and Gate Activity Not touch each other Make sure the exposed wires do not touch each otherDIP Switches Control Board SettingsPotentiometers Remove the Transmitter Cover Setting the Personal Transmitter CodeSet the transmitter DIP Switches Run the cable through PVC conduit to protect it from damage Mounting the ReceiverMemory For Push-to-Open Installations Setting the Closed Position Limit SwitchStep For Pull-to-Open Installations Step Connecting Additional Safety Devices Photoelectric Beams Compatible Safety DevicesSafety Edges ORG orange used with GRN green Connecting AccessoriesWHT white used with GRN green BLU blue used with GRN greenStep PTO-2 Push-to-Open InstallationStep PTO-1 Step PTO-6 Step PTO-3Step PTO-4 Step PTO-5Maintenance Maintenance and Troubleshooting GuidePage GTO, Inc., 3121 Hartsfield Road, Tallahassee, Florida, USA Warranty and Repair ServiceLimited Two Year Warranty Column Installation Information GTO/PRO 2200 Dual Gate System Second Unit Parts ListStepD2 Installing The Second UnitGTO Automatic Gate Lock see Accessory Catalog Step D1Step D-5 Connecting the Second Operator to the Control BoardStepD3 Step D-4Step D-9 Setting the Control Board for Dual Gate InstallationsStep D-7 Step D-8Step D-11 GTO Nema Box FM317 Accessories Available Through Your DealerRB101 Master Pin Lock RB975 ACCESS-ories433IH RB509Replacement Batteries Access -oriesInstallation of this operator conforms to Class Installation Check list