GTO RB923 rev Consumer/End User, No ONE should Cross the Path of the Moving Gate

Page 8

IMPORTANT SAFETY INSTRUCTIONS

Consumer/End User

WARNING: To reduce the risk of injury or death:

1. READ AND FOLLOW ALL INSTRUCTIONS.

2. Distribute and discuss copies of the IMPORTANT SAFETY INSTRUCTIONS with all persons authorized to use your gate.

3. Always keep people and objects away from the gate and its area of travel.

NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE.

4. Your automatic gate is not for pedestrian use. If pedestrian traffic is expected near the gate, a walk-through gate must be installed for this purpose (see page 6).

5. Do not allow children or pets near your gate. Never let children operate or play with gate controls. Keep the remote controls away from children and unauthorized users; store controls where children and unauthorized users do not have access to them.

6. If push buttons or key switches are installed, they should be within sight of the gate, yet located far enough from it (at least 10 feet) so the gate cannot be touched while it is in operation. Do not operate any control without watching the movement of the gate.

7. Do not activate your gate operator unless you can see it and can determine that its area of travel is clear of people, pets, or other obstructions.

8. It is your responsibility to make sure that the installer posted warning signs on both sides of your gate. If any of these signs or warning decals become damaged, illegible or missing, replace them immediately. Contact your installer or GTO for replacements.

9. If electric safety edge sensors (or photoelectric sensors) have been installed (see page 6) they should be tested monthly for proper function.

10. KEEP GATES PROPERLY MAINTAINED. Clean the push-pull tube with a soft, dry cloth and apply silicone spray to it at least once per month.

11.Have your gate operator tested monthly and serviced regularly by an experienced technician. The gate MUST stop

and reverse on contact with an obstruction or when an object activates the non-contact sensors. If these functions are observed to operate improperly, discontinue use and have operator serviced immediately.

12.To operate this equipment safely, YOU must receive detailed instructions on disconnecting the operator for manual

gate operation (see page 1). If you feel you have not received full and proper instructions, contact your installer.

13.Disconnect the operator ONLY when the control box power switch is OFF and the gate is NOT moving.

14.SAVE THESE INSTRUCTIONS.

5

Image 8
Contents Series Converting Temperature Table of Contents Important Safety Instructions Disconnecting the OperatorBefore Installation II. During InstallationIII. After Installation Entrapment Alarm UL 325 30A.1.1A Secondary Means of Protection Against EntrapmentConsumer/End User No ONE should Cross the Path of the Moving GateEntrapment Protection Required Safety Precautions for Swing GatesInstall Warning Signs Moving Gate Can Cause Injury Or Death Technical Specifications GTO/PRO 2000 Series Swing Gate OperatorsParts Hardware not to scaleSingle Gate Operator Parts List Control Box and Electrical ComponentsStep Preparing the GatePull-to-Open Single Gate gate opens into the property Installing The Post Bracket Assembly Step Connecting Operator to Post Bracket Assembly 1/ nut. Note when tighteningRear mount bolt, leave it loose Enough for the operator to pivotInstalling the Gate Bracket Installing the Open and Closed Position Stops Mounting the Control Box Never insert the battery with the terminals to the right BatteryPowering the System Gate LengthEstimated Maximum Number of Cycles Per Day Splice wires togetherSolar Zones and Gate Activity Make sure the exposed wires do not touch each other Not touch each otherControl Board Settings DIP SwitchesPotentiometers Remove the Transmitter Cover Setting the Personal Transmitter CodeSet the transmitter DIP Switches Run the cable through PVC conduit to protect it from damage Mounting the ReceiverMemory For Push-to-Open Installations Setting the Closed Position Limit SwitchStep For Pull-to-Open Installations Step Connecting Additional Safety Devices Photoelectric Beams Compatible Safety DevicesSafety Edges Connecting Accessories WHT white used with GRN greenBLU blue used with GRN green ORG orange used with GRN greenStep PTO-2 Push-to-Open InstallationStep PTO-1 Step PTO-3 Step PTO-4Step PTO-5 Step PTO-6Maintenance and Troubleshooting Guide MaintenancePage GTO, Inc., 3121 Hartsfield Road, Tallahassee, Florida, USA Warranty and Repair ServiceLimited Two Year Warranty Column Installation Information Second Unit Parts List GTO/PRO 2200 Dual Gate SystemInstalling The Second Unit GTO Automatic Gate Lock see Accessory CatalogStep D1 StepD2Connecting the Second Operator to the Control Board StepD3Step D-4 Step D-5Setting the Control Board for Dual Gate Installations Step D-7Step D-8 Step D-9Step D-11 GTO Nema Box FM317 Accessories Available Through Your DealerRB101 ACCESS-ories 433IHRB509 Master Pin Lock RB975Access -ories Replacement BatteriesInstallation Check list Installation of this operator conforms to Class