6127 REMOTE KEYPAD

6128 REMOTE KEYPAD

6137 REMOTE KEYPAD

6138 & 6139

REMOTE KEYPADS

4281L, 4281M, 4281H RF RECEIVERS (5700 System) and

5881L, 5881M, 5881H RF RECEIVERS (5800 System)

5800TM

TRANSMITTER MODULE

used with 5827BD Wireless 2-Way Keypad

4204 RELAY MODULE

4285 PHONE MODULE

7720PLUS/7820

1.Physical: 5-3/4" W x 4-3/4" H x 1" D (146mm x 121mm x 26mm).

2.Electrical: Voltage Input: 12VDC; Current Drain: 20mA.

3.Interface Wiring: Same as 4127.

1.Physical: 5-3/4" W x 4-3/4" H x 1" D (146mm x 121mm x 26mm).

2.Electrical: Voltage Input: 12VDC; Current Drain: 30mA.

3.Interface Wiring: Same as 4127.

1.Physical: 6-1/4" W x 4-3/4" H x 1" D (159mm x 121mm x 26mm).

2.Electrical: Voltage Input: 12VDC; Current Drain: 85mA.

3.Interface Wiring: Same as 4127.

1.Physical: 6-1/4" W x 4-3/4" H x 1" D (159mm x 121mm x 26mm).

2.Electrical: Voltage Input: 12VDC; Current Drain: 100mA.

3.Interface Wiring: Same as 4127.

1.Physical: 7-3/8" (188mm) W x 4-3/8" (112mm) H x 1-7/16" (37mm) D. Note: 10-7/8" (277mm) H with antenna.

2.Electrical: Voltage Input: 12VDC; Current Drain: 35mA.

3.Interface Wiring: Same as 4127.

4.Range: 200ft (60m) nominal indoors from wireless transmitters (the actual range to be determined with system in TEST mode).

5.Zones: (With the Ademco VISTA–10SE)

4281L (4281CN-L*):accepts up to 4 transmitters.

4281M/4281H (4281CN-H*):accepts up to 8 transmitters.

5881L (5882L*): accepts up to 8 transmitters.

5881M/5881H (5882H*): accepts up to 16 transmitters.

*Used in Canada

1.Physical: 2-1/4" W x 4-1/8" H x 7/8" D (57mm x 105mm x 22mm).

2.Electrical: Voltage Input: 12VDC; Current Drain: 20mA.

3.Interface Wiring: Same as 4127.

1.Physical: 6-1/2" W x 4-1/4" H x 1-1/4" D (169mm x 108mm x 32mm).

2.Electrical: Voltage Input: 12VDC; Current Drain: 15mA (Relays off). 180mA (Relays on).

3.Interface Wiring: Same as 4127.

4. Four Output Relays:

SPDT Contacts.

 

Rating: 2A max at 28VDC/AC.

1.Physical: 6-1/2" W x 4-1/4" H x 1-1/4" D (169mm x 108mm x 32mm).

2.Electrical: Voltage Input: 12VDC; Current Drain: 160mA.

3.Device Address: Permanently set to address 4.

4.Interface Wiring: See 4285 PHONE MODULE section.

5.Telephone Line Connections: See 4285 PHONE MODULE section.

1.Physical: 8-1/2" W x 9-1/2" H x 1-3/4" D (216mm x 242mm x 45mm).

2.Electrical: Voltage Input: 12VDC; Current Drain: 150mA.

3.Device Address: Set to address 3.

4.Interface Wiring: Same as 4127 above.

– 81 –

Image 81
Contents VISTA-10SE Recommendations For Proper Intrusion Protection Recommendations For Smoke And Heat DetectorsTable of Contents Relay Output Devices For 5800 Series Wireless Transmitters Section Sequential ModeList of Figures HOW to USE this Manual Conventions Used in this Manual General Description Wireless ExpansionBack-Up Battery AC Power SupplyOptional Phone module Supports the Ademco 4285 Phone module Communication FormatsInstalling the Control Installing the Lock if usedMounting the Cabinet Relay Unit if installed in cabinet Standard Telephone Line Connections Standard Phone Line ConnectionsInstalling The Back-Up Battery Wiring The AC TransformerWiring Table Do not Connect the Wires to the Battery YETInstalling Remote Keypads Wiring To The KeypadsKeypads That May Be Used Keypad Connections To The Control Board Mounting the KeypadsUsing a Supplementary Power Supply For Keypads Preliminary Check-out ProcedureInstalling the Hard-Wired Zones Basic HARD-WIRED ZonesWiring Burglary and Panic Devices To Zones Wiring 4-Wire Smoke/Combustion Detectors on ZoneProgramming Hard-Wired Zones Zone Types Check-Out Procedure For Hard-Wired Zones Special Notes on ZoneProgramming Wireless Systems Available Wireless RF Zone Expansion 5800 RF SystemsSeries Receiver Wireless Zones Wireless System Operation and Transmitter SupervisionWireless System Installation Advisories Transmitter Battery LifeInstallation and Setup of the 4281/5881 Wireless Receivers Receiver SupervisionBoard Series Transmitter SetupOn 5700 Series Setting the DIP SwitchesRefer to the Compatible 5700 Series TransmittersDIP Switch Tables for 5700 RF System Wireless Devices Model Product Zone/ID # Description Compatible 5700 Series TransmittersUsing the House ID Sniffer Mode 5700 Systems Programming the Control For a 5700 Wireless SystemEnter your Installer Code + # + Zone Programming For 5700 TransmittersProgramming Guide Enter the Installer Code + # + Programming 5700 RFSystems Series Transmitter Setup Temp Compatible 5800 Series TransmittersGBD Programming the RF Transmitters 5800 RF SystemsRF House ID Code Enrolling 5800 Transmitters Into The SystemEnrolling Through Zone Programming ZN ZT RC In L 0 0 0 0 RF Transmitter before proceeding to the next zone Recommend that you confirm the programming of everyCheck-Out Procedure for Wireless Zones Sniffer ModeTransmitter ID Go/No Go Test Relay Output Devices Relay Device BasicsRelay Modules Alarm Programming Output Relays Choices for Zone Types Example of Output Relay Programming Phone Module Wiring Installing the Phone modulePhone Module General InformationCaller ID Units Terminal Connects to4285 Wiring NotesPress 95. Ring Detection Count Programming The Control For Phone AccessVoice Answering Module Downloading Field 95 ProgrammingChecking the Operation of the 4285 Phone module To Check Phone module Operation From an On-Premises PhoneTo Check Phone module Operation From an Off-Premises Phone External Sounders Testing the Sounder Press 30. Alarm Bell TimeoutSounder Connections Press 51. Confirmation of Arming DingLong Range Radio General InformationConnection Audio Alarm Verification AAV Wiring ConnectionsProgramming Connection Of AAV Unit When Not Using a 4285 Phone module To bypass this delay, press # + Final Power UPCalculating the Battery Size Needed ExampleConnections Making the BatteryDevice Current # Units Total Current Total =Section Entering Zone Descriptors program menu modeProgramming the Descriptors PressO R Press 6 to accept the selected word Press 8 to save all words in memoryAlternate Method For Programming Zone Descriptors Method For Adding Custom Words Alpha Vocabulary ListSequential Mode For 5800 Series Wireless Transmitters Serial # ↑ Page Following describes each format in greater detail System Communication+1/4+1 Report Standard Expanded Ademco Contact ID Reporting takes the following formatTable of Contact ID Event Codes Communication ProgrammingPress 46 Report FORMAT, PRIMARY/SECONDARY Press 45 Phone System Select Enter 1 digit default =Press 47 SPLIT/DUAL Reporting To Primary Phone No To Secondary Phone NoPress 60 Trouble Report Code To Program System Status and Restore Report Codes 60 68, 70Press 61 Bypass Report Code Press 62 AC Loss Report CodePress 67 RF XMTR. LOW Battery Report Code Press65 OPEN/EXIT Alarm Report CODE, 1st DigitsPress 68 Cancel Report Code Press 70 Alarm Restore Report CODE, 1st DigitPress 75 RF XMTR. LOW Battery Restore Code Press 74 LOW BAT Restore Report CodePress 92 Number of Reports in Armed Period Press 94 Download Phone NumberTest Procedure Testing the SystemTo the Installer To program a Duress code System OperationTo change the Duress code To delete the Duress codeKeypad Functions Features for Each Arming ModeDisarmed, Not Ready Forced Quick BypassIf used Keys Displayed as ZoneRelay Outputs Security Code + # +Trouble Conditions See Troubleshooting Guide also System including Wireless Troubleshooting GuideControl Please Before you call Technical Support, be sure youRead the Instructions Specifications Specifications & AccessoriesVISTA-10SE Security Control Remote Keypad Remote KeypadsTransmitter Module Relay Module Phone ModuleZones With the Ademco VISTA-10SE No CN Accessories Compatible DevicesAdemco 702 Outdoor SirenFederal Communications Commission FCC Part 68 Statement Federal Communications Commission FCC Part 15 StatementUL Notices Canadian Department of Communications DOC Statement Limitations of this Alarm System ADT VISTA-10SE Summary of Connections Ademco Limited Warranty