VistaQuest N7227V5 Keys Displayed as Zone, If used, Relay Outputs, Security Code + # +

Page 75

Panic Keys There are three individual panic keys or, on some keypads, panic key pairs. If programmed, they can be used to manually initiate alarms and send a report to the central station.

Each key (or key pair) can be individually programmed for 24-hour Silent, Audible, Personal or Fire Emergency responses. The panic function is activated when both keys of the appropriate key pair are pressed at the same time, or the appropriate lettered key is pressed for at least 2 seconds.

ARMED READY

A

B

C

D

 

A

 

 

 

OFF

AWAY

 

STAY

 

 

 

 

 

1

 

2

 

3

 

B

 

 

 

MAX

TEST

BYPASS

 

 

 

 

 

4

 

5

 

6

 

C

 

INSTANT

CODE

 

CHIME

 

 

 

 

 

7

 

8

 

9

 

D

 

 

READY

 

 

 

 

 

 

 

 

*

 

0

 

#

PANIC

Shown on the left is a typical keypad with individual Panic keys (shown lettered).

The panic functions are identified by the system as follows:

Keys

Displayed as Zone

 

 

[A], or [1] & [ ]

95

 

 

[B], or [] & [#]

7

 

 

[C], or [3] & [#]

96

 

 

Notes:

Keys [A], [B], [C] are not on all keypads.

Key [D], if present, is not active here.

 

Important: For the Silent Panic functions to be of practical value, the system

 

must be connected to a central station.

4285 Phone module

Refer to the separate instructions supplied with the Phone module for

(if used)

information concerning its operating procedures.

 

 

 

Note: The Phone module cannot be used to add user codes in this system.

 

User codes must be added by using a wired keypad.

Relay Outputs

 

If relay outputs are used, two keypad entries available to the user are included

(if used)

among the system operation choices (34 and 35) that may be programmed

 

(see the RELAY OUTPUTS section). They can manually activate or de-

 

activate the relay(s) for starting or stopping some action, such as turning lights

 

on or off, etc.

 

These keypad entries are: Security Code + [#] + [7]

 

and Security Code + [#] + [8]

 

Note: Whichever entry is used to start/stop the action cannot also be used

 

to stop/start it. The opposite action must either be performed by the

 

other keypad entry or by some other event or operation offered in the

 

programming section.

Exit Alarm

A display of "CANCELED ALARM" or "CA" and a zone indication will

Displays

appear if an exit or interior zone contained a fault during closing at the time

(if programmed)

the exit delay ended (e.g., exit door left open), but the system was

 

disarmed during the entry delay time. The alarm sounder and keypad

 

sound continuously, but stop when the system is disarmed. No message

 

will be transmitted to the central station.

A display of "EXIT ALARM" or "EA" and a zone indication will appear if an exit or interior zone contained a fault during closing at the time the exit delay ended, but the system was NOT disarmed during the entry delay time. The alarm sounder and keypad sound continuously until the system is disarmed (or timeout occurs). An "exit alarm" message is sent to the central

station.

(Continued)

 

– 75 –

Image 75
Contents VISTA-10SE Recommendations For Proper Intrusion Protection Recommendations For Smoke And Heat DetectorsTable of Contents Relay Output Devices For 5800 Series Wireless Transmitters Section Sequential ModeList of Figures HOW to USE this Manual Conventions Used in this Manual General Description Wireless ExpansionCommunication Formats AC Power SupplyBack-Up Battery Optional Phone module Supports the Ademco 4285 Phone moduleInstalling the Control Installing the Lock if usedMounting the Cabinet Relay Unit if installed in cabinet Standard Telephone Line Connections Standard Phone Line ConnectionsDo not Connect the Wires to the Battery YET Wiring The AC TransformerInstalling The Back-Up Battery Wiring TableInstalling Remote Keypads Wiring To The KeypadsKeypads That May Be Used Keypad Connections To The Control Board Mounting the KeypadsUsing a Supplementary Power Supply For Keypads Preliminary Check-out ProcedureWiring 4-Wire Smoke/Combustion Detectors on Zone Basic HARD-WIRED ZonesInstalling the Hard-Wired Zones Wiring Burglary and Panic Devices To ZonesProgramming Hard-Wired Zones Zone Types Check-Out Procedure For Hard-Wired Zones Special Notes on ZoneProgramming Wireless System Operation and Transmitter Supervision Wireless RF Zone Expansion 5800 RF SystemsWireless Systems Available Series Receiver Wireless ZonesReceiver Supervision Transmitter Battery LifeWireless System Installation Advisories Installation and Setup of the 4281/5881 Wireless ReceiversBoard Series Transmitter SetupTransmitters Setting the DIP SwitchesOn 5700 Series Refer to the Compatible 5700 SeriesDIP Switch Tables for 5700 RF System Wireless Devices Model Product Zone/ID # Description Compatible 5700 Series TransmittersZone Programming For 5700 Transmitters Programming the Control For a 5700 Wireless SystemUsing the House ID Sniffer Mode 5700 Systems Enter your Installer Code + # +Programming Guide Enter the Installer Code + # + Programming 5700 RFSystems Series Transmitter Setup Temp Compatible 5800 Series TransmittersGBD Programming the RF Transmitters 5800 RF SystemsRF House ID Code Enrolling 5800 Transmitters Into The SystemEnrolling Through Zone Programming ZN ZT RC In L 0 0 0 0 RF Transmitter before proceeding to the next zone Recommend that you confirm the programming of everyCheck-Out Procedure for Wireless Zones Sniffer ModeTransmitter ID Go/No Go Test Relay Output Devices Relay Device BasicsRelay Modules Alarm Programming Output Relays Choices for Zone Types Example of Output Relay Programming General Information Installing the Phone modulePhone Module Wiring Phone ModuleCaller ID Units Terminal Connects to4285 Wiring NotesDownloading Field 95 Programming Programming The Control For Phone AccessPress 95. Ring Detection Count Voice Answering ModuleChecking the Operation of the 4285 Phone module To Check Phone module Operation From an On-Premises PhoneTo Check Phone module Operation From an Off-Premises Phone External Sounders Press 51. Confirmation of Arming Ding Press 30. Alarm Bell TimeoutTesting the Sounder Sounder ConnectionsLong Range Radio General InformationConnection Audio Alarm Verification AAV Wiring ConnectionsProgramming Connection Of AAV Unit When Not Using a 4285 Phone module Example Final Power UPTo bypass this delay, press # + Calculating the Battery Size NeededTotal = Making the BatteryConnections Device Current # Units Total CurrentPress Entering Zone Descriptors program menu modeSection Programming the DescriptorsO R Press 6 to accept the selected word Press 8 to save all words in memoryAlternate Method For Programming Zone Descriptors Method For Adding Custom Words Alpha Vocabulary ListSequential Mode For 5800 Series Wireless Transmitters Serial # ↑ Page Following describes each format in greater detail System Communication+1/4+1 Report Standard Expanded Ademco Contact ID Reporting takes the following formatTable of Contact ID Event Codes Communication ProgrammingTo Primary Phone No To Secondary Phone No Press 45 Phone System Select Enter 1 digit default =Press 46 Report FORMAT, PRIMARY/SECONDARY Press 47 SPLIT/DUAL ReportingPress 62 AC Loss Report Code To Program System Status and Restore Report Codes 60 68, 70Press 60 Trouble Report Code Press 61 Bypass Report CodePress 70 Alarm Restore Report CODE, 1st Digit Press65 OPEN/EXIT Alarm Report CODE, 1st DigitsPress 67 RF XMTR. LOW Battery Report Code Press 68 Cancel Report CodePress 94 Download Phone Number Press 74 LOW BAT Restore Report CodePress 75 RF XMTR. LOW Battery Restore Code Press 92 Number of Reports in Armed PeriodTest Procedure Testing the SystemTo the Installer To delete the Duress code System OperationTo program a Duress code To change the Duress codeForced Quick Bypass Features for Each Arming ModeKeypad Functions Disarmed, Not ReadySecurity Code + # + Keys Displayed as ZoneIf used Relay OutputsTrouble Conditions See Troubleshooting Guide also System including Wireless Troubleshooting GuideControl Please Before you call Technical Support, be sure youRead the Instructions Remote Keypads Specifications & AccessoriesSpecifications VISTA-10SE Security Control Remote KeypadTransmitter Module Relay Module Phone ModuleZones With the Ademco VISTA-10SE Siren Accessories Compatible DevicesNo CN Ademco 702 OutdoorFederal Communications Commission FCC Part 68 Statement Federal Communications Commission FCC Part 15 StatementUL Notices Canadian Department of Communications DOC Statement Limitations of this Alarm System ADT VISTA-10SE Summary of Connections Ademco Limited Warranty