VistaQuest N7227V5 Wiring The AC Transformer, Installing The Back-Up Battery, Wiring Table

Page 14

Wiring The AC Transformer

No. 1321 Wire the No. 1321 transformer to terminals 1 and 2 on the control board. See wiring table below for wire gauge to use.

WIRING TABLE

Distance of Transformer

Wire Gauge

From the Control Panel

To Use

Up to 50 feet

# 20

 

 

50–100 feet

# 18

 

 

100–250 feet

# 16

 

 

Wiring to the AC Transformer must not exceed 250 feet using 16 gauge wire. Do not plug the transformer into the AC outlet until you are instructed to do so later in the manual.

Installing The Back-Up Battery

Do not attach the connector cable to the battery terminals until you are instructed to do so later in the manual.

1.Place the 12-volt back-up battery in the control cabinet.

2.Attach Red and Black wires on the battery connector cable to the control board as follows:

a.Red to the positive (+) battery tab on the control board (see Summary of Connections Diagram for location, if necessary).

b.Black to the negative () battery tab on the control board.

These wires may have already been connected to the battery tabs on the control board. If so, disregard steps a. and b.

DO NOT CONNECT THE WIRES TO THE BATTERY YET!

UL Use a 4AH battery or larger for UL installations.

Earth Ground Connections

The designated earth ground terminal (21), must be terminated in a good earth ground for the lightning transient protective devices in this product to be effective. The following are examples of good earth grounds available at most installations:

Metal Cold Water Pipe:

Use a non-corrosive metal strap (copper is recommended) firmly secured to the pipe to which the ground lead is electrically connected and secured.

AC Power Outlet Ground:

Available from 3-prong, 120VAC, power outlets only. To test the integrity of the ground terminal, use a three-wire circuit tester with neon lamp indicators, such as the UL -Listed Ideal Model 61–035, or equivalent, available at most electrical supply stores.

– 14 –

Image 14
Contents VISTA-10SE Recommendations For Smoke And Heat Detectors Recommendations For Proper Intrusion ProtectionTable of Contents Relay Output Devices Sequential Mode For 5800 Series Wireless Transmitters SectionList of Figures HOW to USE this Manual Conventions Used in this Manual Wireless Expansion General DescriptionOptional Phone module Supports the Ademco 4285 Phone module AC Power SupplyBack-Up Battery Communication Formats Mounting the Cabinet Installing the Control Installing the Lock if used Relay Unit if installed in cabinet Standard Phone Line Connections Standard Telephone Line ConnectionsWiring Table Wiring The AC TransformerInstalling The Back-Up Battery Do not Connect the Wires to the Battery YETKeypads That May Be Used Installing Remote KeypadsWiring To The Keypads Mounting the Keypads Keypad Connections To The Control BoardPreliminary Check-out Procedure Using a Supplementary Power Supply For KeypadsWiring Burglary and Panic Devices To Zones Basic HARD-WIRED ZonesInstalling the Hard-Wired Zones Wiring 4-Wire Smoke/Combustion Detectors on ZoneProgramming Hard-Wired Zones Zone Types Programming Check-Out Procedure For Hard-Wired ZonesSpecial Notes on Zone Series Receiver Wireless Zones Wireless RF Zone Expansion 5800 RF SystemsWireless Systems Available Wireless System Operation and Transmitter SupervisionInstallation and Setup of the 4281/5881 Wireless Receivers Transmitter Battery LifeWireless System Installation Advisories Receiver SupervisionSeries Transmitter Setup BoardRefer to the Compatible 5700 Series Setting the DIP SwitchesOn 5700 Series TransmittersDIP Switch Tables for 5700 RF System Wireless Devices Compatible 5700 Series Transmitters Model Product Zone/ID # DescriptionEnter your Installer Code + # + Programming the Control For a 5700 Wireless SystemUsing the House ID Sniffer Mode 5700 Systems Zone Programming For 5700 TransmittersProgramming Guide Systems Enter the Installer Code + # +Programming 5700 RF Series Transmitter Setup Compatible 5800 Series Transmitters TempProgramming the RF Transmitters 5800 RF Systems GBDEnrolling Through Zone Programming RF House ID CodeEnrolling 5800 Transmitters Into The System ZN ZT RC In L 0 0 0 0 RF Recommend that you confirm the programming of every Transmitter before proceeding to the next zoneTransmitter ID Check-Out Procedure for Wireless ZonesSniffer Mode Go/No Go Test Relay Modules Relay Output DevicesRelay Device Basics Alarm Programming Output Relays Choices for Zone Types Example of Output Relay Programming Phone Module Installing the Phone modulePhone Module Wiring General InformationTerminal Connects to Caller ID UnitsWiring Notes 4285Voice Answering Module Programming The Control For Phone AccessPress 95. Ring Detection Count Downloading Field 95 ProgrammingTo Check Phone module Operation From an Off-Premises Phone Checking the Operation of the 4285 Phone moduleTo Check Phone module Operation From an On-Premises Phone External Sounders Sounder Connections Press 30. Alarm Bell TimeoutTesting the Sounder Press 51. Confirmation of Arming DingConnection Long Range RadioGeneral Information Programming Audio Alarm Verification AAVWiring Connections Connection Of AAV Unit When Not Using a 4285 Phone module Calculating the Battery Size Needed Final Power UPTo bypass this delay, press # + ExampleDevice Current # Units Total Current Making the BatteryConnections Total =Programming the Descriptors Entering Zone Descriptors program menu modeSection PressO R Alternate Method For Programming Zone Descriptors Press 6 to accept the selected wordPress 8 to save all words in memory Method Alpha Vocabulary List For Adding Custom WordsSequential Mode For 5800 Series Wireless Transmitters Serial # ↑ Page System Communication Following describes each format in greater detailAdemco Contact ID Reporting takes the following format +1/4+1 Report Standard ExpandedCommunication Programming Table of Contact ID Event CodesPress 47 SPLIT/DUAL Reporting Press 45 Phone System Select Enter 1 digit default =Press 46 Report FORMAT, PRIMARY/SECONDARY To Primary Phone No To Secondary Phone NoPress 61 Bypass Report Code To Program System Status and Restore Report Codes 60 68, 70Press 60 Trouble Report Code Press 62 AC Loss Report CodePress 68 Cancel Report Code Press65 OPEN/EXIT Alarm Report CODE, 1st DigitsPress 67 RF XMTR. LOW Battery Report Code Press 70 Alarm Restore Report CODE, 1st DigitPress 92 Number of Reports in Armed Period Press 74 LOW BAT Restore Report CodePress 75 RF XMTR. LOW Battery Restore Code Press 94 Download Phone NumberTesting the System Test ProcedureTo the Installer To change the Duress code System OperationTo program a Duress code To delete the Duress codeDisarmed, Not Ready Features for Each Arming ModeKeypad Functions Forced Quick BypassRelay Outputs Keys Displayed as ZoneIf used Security Code + # +Trouble Conditions See Troubleshooting Guide also Troubleshooting Guide System including WirelessControl Read the Instructions PleaseBefore you call Technical Support, be sure you VISTA-10SE Security Control Remote Keypad Specifications & AccessoriesSpecifications Remote KeypadsZones With the Ademco VISTA-10SE Transmitter ModuleRelay Module Phone Module Ademco 702 Outdoor Accessories Compatible DevicesNo CN SirenFederal Communications Commission FCC Part 15 Statement Federal Communications Commission FCC Part 68 StatementUL Notices Canadian Department of Communications DOC Statement Limitations of this Alarm System ADT VISTA-10SE Summary of Connections Ademco Limited Warranty