If you purchased your SPAN-CPT product in Europe, please return it to your dealer or supplier at the end of its life. The objectives of the European Community's environment policy are, in particular, to preserve, protect and improve the quality of the environment, protect human health and utilise natural resources prudently and rationally. Sustainable development advocates the reduction of wasteful consumption of natural resources and the prevention of pollution. Waste electrical and electronic equipment (WEEE) is a regulated area. Where the generation of waste cannot be avoided, it should be reused or recovered for

its material or energy. WEEE products may be recognized by their wheeled bin label ().1

Lightning Protection Installation and Grounding Procedure

What is the hazard?

A lightning strike into the ground causes an increase in the earth's potential which results in a high voltage potential between the center conductor and shield of the coaxial cable. This high voltage develops because the voltage surge induced onto the center conductor lags in time behind the voltage surge induced onto the shield.

Hazard Impact

A lightning strike causes the ground potential in the area to rise to dangerous levels resulting in harm to personnel or destruction of electronic equipment in an unprotected environment. It also conducts a portion of the strike energy down the inner conductor of the coax cable to the connected equipment.

Only qualified personnel, electricians as mandated by the governing body in the country of installation, may install lightning protection devices.

Actions to Mitigate Lightning Hazards

1.Do not install antennas or antenna coaxial cables outside the building during a lightning storm.

2.It is not possible to avoid over-voltages caused by lightning, but a lightning protection device may be used to shunt a large portion of the transient energy to the building ground reducing the over-voltage condition as quickly as possible.

3.Primary lightning protection must be provided by the operator/customer according to local building codes as part of the extra-building installation.

4.To ensure compliance with clause 7 "Connection to Cable Distribution Systems" of EN 60950-1, Safety for Information Technology Equipment, a secondary lightning protection device must be used for in-building equipment installations with external antennas. The following device has been approved by NovAtel Inc.:

Polyphaser - Surge Arrestor DGXZ+24NFNF-A

If this device is not chosen as the primary lightning protection device, the device chosen must meet the following requirements:

UL listed, or equivalent, in country of installation (for example, TUV, VDE and so on) for lightning surge protection

The primary device must be capable of limiting an incoming surge to 10kV

5.The shield of the coaxial cable entering the building should be connected at a grounding plate at the building's entrance. The lightning protection devices should have their chassis grounded to the same ground near to the building's entrance.

1.Visit the NovAtel Web site at www.novatel.com through Products WEEE and RoHS for more infor- mation on WEEE.

SPAN-CPT User Manual Rev 8

9

Image 9
Contents SPAN-CPT Return instructions Proprietary Notice WarrantyTable of Contents Technical Specifications Figures Tables Contact Information NovAtel Knowledge Base Before Contacting Customer SupportFCC Notices Industry CanadaCE Notice What is the hazard? Lightning Protection Installation and Grounding ProcedureWeee Notice Hazard ImpactPrimary and Secondary Lightning Protection Ref # Description Fundamentals of GNSS+INS IntroductionSystem Components Related Documents and InformationConventions Required Equipment SPAN-CPT InstallationManuals SPAN-CPT HardwareTypical SPAN-CPT Set Up Radio COM2 Hardware Set UpMount the SPAN-CPT Mount the AntennaConnect the Gnss Antenna Connect PowerConnect the I/O Strobe Signals Battery Isolator Auxiliary Vehicle MainBatteryConnect a Computer to the SPAN-CPT Can Bus Odometer ConnectionOdometer Requirements Cable Modification for SPAN-CPT Cable Cable Modification for Kistler WPT CableSPAN-CPT Operation Definition of Reference Frames Within SpanLocal Level Frame Full Mapping Definitions Span Body FrameVehicle Frame Enclosure FrameUse NovAtel Connect to Communicate Communicating with the SPAN-CPT SystemChapter SPAN-CPT Operation Gnss Configuration Software ConfigurationSpan IMU Configuration SPAN-CPT Configuration with NovAtel ConnectReal Time Operation Ascii System Start-Up and Alignment TechniquesSetimuorientation Default Kinematic AlignmentNavigation Mode Manual AlignmentDual Antenna Alignment Wheel Sensor Update Logic Azimuth Sources on a Span SystemCourse Over Ground Inertial Azimuth Align AzimuthLogs with Azimuth data Data Collection Solution ParametersData Collection for Post-Processing  Logging RestrictionVariable Lever Arm Enabling L-BandNovAtel Correct with TerraStar OmniSTAR Veripos Marine SubscriptionsChapter SPAN-CPT Operation SPAN-CPT Dual-Antenna InstallationPower Supply Configuring Span with Align on SPAN-CPTChapter SPAN-CPT Dual-Antenna SecondaryAlignment on a Moving Vessel Aided Transfer Alignment Alignment on a Stationary Vehicle Aided Static AlignmentUnaided Alignment Automatic Alignment Mode Automatic Alignment default Span Align Attitude UpdatesFirmware Updates and Model Upgrades Firmware UpdatesNovAtel Firmware and Software Model Upgrades Authorization CodeUpdating or Upgrading Using the WinLoad Utility Transferring Firmware FilesTypes of Firmware Files Open a File to Download Using the WinLoad UtilitySearching for Card Updating using SoftLoad CommandsSoftloadsrec S-RECORD Working with S-RecordsUpgrading Using the Auth Command Key Firmware CommandsUpgrade Procedure SPAN-CPT Technical Specifications Technical SpecificationsHardware Specification for SPAN-CPT KVH IMU Sensor SpecificationsPower Specifications Electrical and Environmental SpecificationsSPAN-CPT Side and Perspective View SPAN-CPT Mechanical DrawingsSPAN-CPT Top, Front and Bottom View SPAN-CPT 60723108 KVH Development Terminated Cable Pin-Out SPAN-CPT CableFemale Male SPAN-CPT 60723107 KVH Standard Un-terminated Cable Pin-Out Pin Function Wire Pair Wire ColorReplacement Parts Accessories and OptionsSPAN-CPT System Appendix C Frequently Asked QuestionsOM-20000122 Rev March