Baldor MN1940 installation manual DSMS17x-3A

Page 37

 

 

 

 

 

 

 

 

www.baldormotion.com

7.1.2.3 DSMS17x-3A...

 

 

 

 

 

 

 

 

 

60

 

 

 

 

 

 

42

 

 

50

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

 

(oz·in)

40

 

 

 

 

 

 

28

Torque

30

 

 

 

 

 

 

21

Torque

20

 

 

 

 

 

 

14

(N·cm)

10

 

24 VDC

 

 

 

 

7

 

 

 

 

 

 

 

 

 

48 VDC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

0

1000

2000

3000

4000

5000

6000

7000

 

 

 

(300)

(600)

(900)

(1200)

(1500)

(1800)

(2100)

 

Speed in full steps per second (RPM)

Description

Holding torque

Detent torque

Rotor inertia

Value

52.9N·cm (74.9 oz·in)

2.45N·cm (3.47 oz·in)

0.082 kg·cm2 (0.00116 oz·in·s2)

MN1940

Specifications 7-3

Image 37
Contents DSM S-Series Integrated Stepper Motor / Driver Page Contents Troubleshooting General Information Precautions Safety NoticeMN1940 Introduction DSM S-Series integrated motor and driverModel ‘F’ ‘P’ ‘M’ Option availabilityReceiving and inspection InstalledIdentifying the catalog number Units and abbreviations PhaseIntroduction You should read all the sections in Basic InstallationLocation requirements Dimensions Weight Dimensions DSMS17Mounting the DSM Screw thread limitation DSMS17 DSMS23x-1B Dimensions DSMS23DSMS23x-2B DSMS23x-3BMotor Dimensions Dimensions DSMS34Securing DSM cables Other requirements for installation Basic connections SPI interface ‘P’ connectorMotor power input Power wire ratings Wire sizesCable length Minimum Logic inputs Enable brown flying leadLogic input descriptions Step clock orange flying leadInput timing Sinking input configurations Sinking / sourcing input configurationDIR0 SPI interface SPI connectorPin Name Description SPI signal descriptions X12 Connection summary minimum system wiringNextMove ESB Installing the USB driver Connecting the DSM to the PCInstalling the virtual COM port driver Determining the virtual COM port number Installing Baldor SPI Interface\BaldorSPIInterface.exe Starting the controller and DSM Motion settings view Configuration parametersName Range Units Default Baldor SPI InterfaceHold Current Delay Time Hcdt Microstep Resolution Select MselRecall! and Upgrade! menu options Msel valueClock Type 2.2 I/O settings viewClock IOF Communication problems Problem diagnosisSymptom Check Further supportMotor control problems Maximum supply voltage +48VDC +75VDC Input powerInput current maximum Detent torque DSMS17x-1ARotor inertia DSMS17x-2ADSMS17x-3A DSMS23x-2B DSMS23x-1BDSMS23x-3B DSMS34x-1B Motor speed & torque DSMS34DSMS34x-2B DSMS34x-3B Digital inputs Specifications MN1940 Index Index MN1940 Comment CommentsComments MN1940 Page LT0227A02