Alliance Laundry Systems PHM798N, PHM802N manual Washer-Extractors

Page 1

Washer-Extractors

Pocket Hardmount

UniLinc and M30 Control

Refer to Page 8 for Model Numbers

PHM798N

PHM798N

UniLinc 35 – 125 Models

PHM1422C

UniLinc 150 Model

PHM1422C

PHM802N

PHM802N

M30 35 – 125 Models

Keep These Instructions for Future Reference.

(If this machine changes ownership, this manual must accompany machine.)

www.comlaundry.com

Part No. F8138601R11

June 2011

Installation

Image 1
Contents Washer-Extractors Page Contents Important Safety Instructions Explanation of Safety MessagesSafety Information Safety Decals Operator Safety Environmental Conditions Safe Operating EnvironmentMachine Location AC Inverter Drive Input and Output ServicesModel Identification IntroductionCustomer Service Replacement PartsDelivery Inspection Name plate LocationModel Number Familiarization Guide Models Starting 4/1/09 0001Wash Cylinder Information Weight And Shipping InformationDoor Opening Information Drive Train InformationDirect Steam Heating Optional Balance DetectionElectrical Heating Optional Overall width, in. mm MED Specifications and Dimensions Machine DimensionsCrush hazard Uwtv Models Through 3/31/09UW35TV UW125TV Models UW150TV Models Dimension 35 125 Models Models UW Design 3 Models starting 10/4/10 Refer to and Figure Base BA Base Overall PHM807N Machine Foundation Requirements Proceed to Machine Mounting and Grouting section Concrete Foundation Pad InstallationLength for ONE Machine Floor Load Data 1272 1442 Speed 1745 2392 Speed 1797 2342 10.4 Mounting Bolt Installation Requirements Machine Mounting and Grouting Speed Models only Mounting Bolt Hole LocationsVARIABLE-SPEED Model Front of Machine 80 / 100 Models 1181 mm 178 mm 254 mm Model 35 2-SPEED Model Grout PlacementFor UniLinc Models, Navigate to the Inputs Outputs Menu Gap Setting for Vibration SwitchPound Model 60, 80, 100 and 125 Pound Models Design 1 150 Pound Model Drain Connection Requirements Drain Trough ConfigurationDrain Information Specifications 100 125 150 Water Connection Water Supply Information Specifications 80/100 125/150Air Cushions Risers 50Hz Conversion Electrical Installation RequirementsDo not use a phase adder on any variable- speed machine Specifications and Dimensions Cycle CodeM30 Control Models only Steam Supply Information 100 125/150 Steam Requirements Steam Heat Option OnlyChemical Injection Supply System Chemical Injection Supply System Connecting External Liquid Supplies to the Washer-ExtractorPHM553N External Supplies Chemical Injection Using Internal 24VAC Control Transformer Chemical injection Using External AC Power Source External Supply Signals ES1 Power supply Supply 1 Signal K1 Contact