Alliance Laundry Systems PHM802N 0001, Model Number Familiarization Guide Models Starting 4/1/09

Page 12

Introduction

Model Number Familiarization Guide - Models Through 3/31/09

Sample Model Number: UW60TVQU10001

UW Model Number Prefix

60Washer-Extractor Capacity (60 pounds dry weight of laundry)

T

Type of Electrical Control

T = UniLinc Control

 

 

 

V

Washer-Extractor Speed Capabilities

V = 8 Speeds

 

 

 

Q

Electrical Characteristics

Refer to Table 10.

 

 

 

U1

Design Series

 

 

 

0001

Option Identification (varies from machine to machine)

 

 

 

 

 

Model Number Familiarization Guide - Models Starting 4/1/09

 

 

 

Sample Model Number: UWN060T3VXU1001

 

 

 

UW

Model Number Prefix

 

NMarket Approvals

060Washer-Extractor Capacity (60 pounds dry weight of laundry)

T

Type of Electrical Control

T = UniLinc Control

 

 

 

3Spray/Dispenser Feature

V

Washer-Extractor Speed Capabilities

V = 8 Speeds

 

 

 

X

Electrical Characteristics

Refer to Table 10.

 

 

 

U1

Design Series

 

0Heat Feature

01Option Identification (varies from machine to machine)

Model No. UWN060T3VXU1001

Serial No.

00000000000

 

Voltage 200 – 240

Hz 50-60

Phase 3

Number of wires : 3

 

FLA : 19

amps

Circuit Breaker Size :

30 amps

 

 

Max. Load :

60

LB

27 KG

 

Schematic :

 

 

 

 

Supply Water: 30 - 85 psi,

2 - 5.7

BAR

EXAMPLE OF SERIAL PLATE

PHM769N

Figure 2

10

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138601

Image 12
Contents Washer-Extractors Page Contents Explanation of Safety Messages Important Safety InstructionsSafety Information Safety Decals Operator Safety Safe Operating Environment Environmental ConditionsMachine Location Input and Output Services AC Inverter DriveIntroduction Model IdentificationReplacement Parts Customer ServiceDelivery Inspection Name plate Location0001 Model Number Familiarization Guide Models Starting 4/1/09Weight And Shipping Information Wash Cylinder InformationDoor Opening Information Drive Train InformationBalance Detection Direct Steam Heating OptionalElectrical Heating Optional Overall width, in. mm MED Machine Dimensions Specifications and DimensionsCrush hazard Uwtv Models Through 3/31/09UW35TV UW125TV Models UW150TV Models Dimension 35 125 Models Models UW Design 3 Models starting 10/4/10 Refer to and Figure Base BA Base Overall PHM807N Machine Foundation Requirements Concrete Foundation Pad Installation Proceed to Machine Mounting and Grouting sectionLength for ONE Machine Floor Load Data 1272 1442 Speed 1745 2392 Speed 1797 2342 10.4 Mounting Bolt Installation Requirements Machine Mounting and Grouting Mounting Bolt Hole Locations Speed Models onlyVARIABLE-SPEED Model Front of Machine 80 / 100 Models 1181 mm 178 mm 254 mm Model Grout Placement 35 2-SPEED ModelGap Setting for Vibration Switch For UniLinc Models, Navigate to the Inputs Outputs MenuPound Model 60, 80, 100 and 125 Pound Models Design 1 150 Pound Model Drain Trough Configuration Drain Connection RequirementsDrain Information Specifications 100 125 150 Water Supply Information Specifications 80/100 125/150 Water ConnectionAir Cushions Risers Electrical Installation Requirements 50Hz ConversionDo not use a phase adder on any variable- speed machine Specifications and Dimensions Code CycleM30 Control Models only Steam Requirements Steam Heat Option Only Steam Supply Information 100 125/150Chemical Injection Supply System Connecting External Liquid Supplies to the Washer-Extractor Chemical Injection Supply SystemPHM553N External Supplies Chemical Injection Using Internal 24VAC Control Transformer Chemical injection Using External AC Power Source External Supply Signals ES1 Power supply Supply 1 Signal K1 Contact