Specifications and Dimensions
UWTV Models Through 3/31/09 (Continued)
Specifications | 35 | 60 | 80 | 100 | 125 | 150 | |||||||
|
|
|
|
|
|
|
|
|
|
| |||
Cylinder Speeds / Centrifugal Force Data |
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
| |||||||
1/2 Wash/reverse, rpm (g) | 26 (.25) | 26 (.31) | 26 (.35) | 26 (.35) | 26 (.40) | 23 (.31) | |||||||
|
|
|
|
|
|
|
| ||||||
Wash/reverse, rpm (g) |
| 42 (.66) | 40 (.73) | 40 (.82) | 40 (.82) | 37 (.82) | 36 (0.8) | ||||||
|
|
|
|
|
|
|
| ||||||
Distribution, rpm (g) |
| 83 (2.57) | 71 (2.29) | 73 (2.57) | 70 (2.50) | 62 (2.29) | 61 (2.29) | ||||||
|
|
|
|
|
|
| |||||||
Very Low extract, rpm (g) | 401 (60) | 364 (60) | 343 (60) | 343 (60) | 317 (60) | 314 (60) | |||||||
|
|
|
|
|
|
|
|
|
|
|
|
| |
Low extract rpm (g) |
| 568 | (120) | 514 | (120) | 485 | (120) | 485 | (120) | 449 | (120) | 444 (120) | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Medium extract, rpm (g) |
| 695 | (180) | 630 | (180) | 594 | (180) | 594 | (180) | 550 | (180) | 543 (180) | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
High extract, rpm (g) |
| 803 | (240) | 727 | (240) | 686 | (240) | 686 | (240) | 565 | (190) | 627 (240) | |
|
|
|
|
|
|
|
|
|
|
|
| ||
Very High extract, rpm (g) | 898 | (300) | 813 | (300) | 766 | (300) | 766 | (300) | 579 | (200) | 701 (300) | ||
|
|
|
|
|
|
|
|
|
|
|
| ||
Balance Detection |
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| |||||||
Vibration switch installed | STD | STD | STD | STD | STD | STD | |||||||
|
|
|
|
|
|
|
|
|
|
| |||
Direct Steam Heating (Optional) |
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| |||||||
Steam inlet connection size, | 0.5 (13) | 0.5 (13) | 0.5 (13) | 0.5 (13) | 0.75 (19) | 0.75 (19) | |||||||
in (mm) |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Number of steam inlets |
|
| 1 |
| 1 |
| 1 |
| 1 |
| 1 | 1 | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
Steam required to |
| LOW | 2.1 | (1.5) | 3.3 | (2.4) | 4.6 | (3.3) | 5.7 | (4.1) | 6.7 | (4.9) | 8.3 (6.0) |
raise bath temperature |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
10°F, lb (10°C, kg) |
| MED | 2.3 | (1.7) | 3.7 | (2.6) | 5.2 | (3.8) | 6.5 | (4.7) | 7.8 | (5.6) | 9.5 (6.9) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| HIGH | 2.7 | (1.9) | 4.1 | (2.9) | 6.1 | (4.4) | 7.6 | (5.5) | 9.1 | (6.6) | 11.1 (8.0) |
|
|
|
|
|
|
|
| ||||||
Average consumption per | 1.4 (21.4) | 2.1 (33.4) | 3.1 (48.4) | 3.8 (60.4) | 4.6 (72.0) | 5.8 (91.0) | |||||||
cycle, BHP (kg) |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| ||
Electrical Heating (Optional) |
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
| ||||||
Total electrical heating |
| 15.6 | 27.4 | 41.2 | 41.2 | N/A | N/A | ||||||
capacity, kW |
|
|
|
|
| 27.4 | 27.4 |
|
|
| |||
|
|
|
|
|
|
|
|
|
|
| |||
Number of electrical heating |
| 6 |
| 6 |
| 9 |
| 9 | N/A | N/A | |||
elements |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| |||||||
Electrical heating element size, | 2.6 | 4.2 | 4.2 | 4.2 | N/A | N/A | |||||||
kW |
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| ||
Time required to |
| LOW | 2.4 | (3.6) | 2.4 | (3.7) | 2.2 | (3.4) | 2.8 | (4.2) | N/A | N/A | |
raise bath temperature |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
10°F, min (5°C, min) |
| MED | 2.7 | (4.1) | 2.7 | (4.1) | 2.5 | (3.9) | 3.2 | (4.8) | N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| HIGH | 3.1 | (4.7) | 3.0 | (4.6) | 3.0 | (4.5) | 3.7 | (5.6) | N/A | N/A | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
12 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | F8138601 |