Alliance Laundry Systems PHM798N Connecting External Liquid Supplies to the Washer-Extractor

Page 55

1

2

3

4

5

6

PHM559N

1Tubing from Pump

2Seal Nut

3Tubing Ring

4Base

5Lid

6Nut

Figure 28

Specifications and Dimensions

Connecting External Liquid Supplies to the Washer-Extractor

1.Remove knockout from supply dispenser. Refer to Figure 28. Plugs are assembled inside the tubing ring.

2.Install PG connector in hole with strain reliefs, included in the seal nut.

3.Insert tubes through PG base. Do not remove cups. Tube should extend into the plastic cup, with the exception of the softener tube, which should be routed to the outside of the cup.

4.Tighten the seal nut to prevent tubing from escaping the assembly.

5.Before operating machine, confirm lid is completely closed.

Do not attempt to make chemical injection electrical connections to points other than those provided specifically for that purpose by the factory.

Chemical Injection Supply System

Number of dry supply compartments

5

 

 

Number of external liquid supply

8

connections

 

 

 

Liquid supply connection size, in. (mm)

0.625 (15.9)

 

 

A bracket, which is located on the left side of the control module, has been provided for mounting the external supply controls. This bracket is present only on models made through 6/30/08. Refer to Figures 5 through 10.

F8138601

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

53

Image 55
Contents Washer-Extractors Page Contents Important Safety Instructions Explanation of Safety MessagesSafety Information Safety Decals Operator Safety Environmental Conditions Safe Operating EnvironmentMachine Location AC Inverter Drive Input and Output ServicesModel Identification IntroductionName plate Location Replacement PartsCustomer Service Delivery InspectionModel Number Familiarization Guide Models Starting 4/1/09 0001Drive Train Information Weight And Shipping InformationWash Cylinder Information Door Opening InformationDirect Steam Heating Optional Balance DetectionElectrical Heating Optional Overall width, in. mm MED Uwtv Models Through 3/31/09 Machine DimensionsSpecifications and Dimensions Crush hazardUW35TV UW125TV Models UW150TV Models Dimension 35 125 Models Models UW Design 3 Models starting 10/4/10 Refer to and Figure Base BA Base Overall PHM807N Machine Foundation Requirements Proceed to Machine Mounting and Grouting section Concrete Foundation Pad InstallationLength for ONE Machine Floor Load Data 1272 1442 Speed 1745 2392 Speed 1797 2342 10.4 Mounting Bolt Installation Requirements Machine Mounting and Grouting Speed Models only Mounting Bolt Hole LocationsVARIABLE-SPEED Model Front of Machine 80 / 100 Models 1181 mm 178 mm 254 mm Model 35 2-SPEED Model Grout PlacementFor UniLinc Models, Navigate to the Inputs Outputs Menu Gap Setting for Vibration SwitchPound Model 60, 80, 100 and 125 Pound Models Design 1 150 Pound Model Drain Connection Requirements Drain Trough ConfigurationDrain Information Specifications 100 125 150 Water Connection Water Supply Information Specifications 80/100 125/150Air Cushions Risers 50Hz Conversion Electrical Installation RequirementsDo not use a phase adder on any variable- speed machine Specifications and Dimensions Cycle CodeM30 Control Models only Steam Supply Information 100 125/150 Steam Requirements Steam Heat Option OnlyChemical Injection Supply System Chemical Injection Supply System Connecting External Liquid Supplies to the Washer-ExtractorPHM553N External Supplies Chemical Injection Using Internal 24VAC Control Transformer Chemical injection Using External AC Power Source External Supply Signals ES1 Power supply Supply 1 Signal K1 Contact