Alliance Laundry Systems PHM802N, PHM798N manual Med

Page 16

Specifications and Dimensions

UWL, UWN and UWU Models Starting 4/1/09 (Continued)

Specifications

35

60

80

100

125

150

 

 

 

 

 

 

 

Cylinder Speeds / Centrifugal Force Data

 

 

 

 

 

 

 

 

 

 

 

1/2 Wash/reverse, rpm (g)

26 (.25)

26 (.31)

26 (.35)

26 (.35)

26 (.40)

23 (.32)

(Variable-speed models only)

 

 

 

 

 

 

 

 

 

 

 

 

 

Wash/reverse, rpm (g)

44 (.73)

42 (.66)

40 (0.8)

40 (0.8)

37 (0.8)

36 (0.8)

 

 

 

 

 

 

 

Distribution, rpm (g)

83 (2.57)

74 (2)

70 (2.50)

70 (2.50)

62 (2.29)

61 (2.29)

(Variable-speed models only)

 

 

 

 

 

 

 

 

 

 

 

 

 

Very Low extract, rpm (g)

401 (60)

364 (60)

343 (60)

343 (60)

317 (60)

314 (60)

(Variable-speed models only)

 

 

 

 

 

 

 

 

 

 

 

 

 

Low extract rpm (g)

568 (120)

514 (120)

485 (120)

485 (120)

449 (120)

444 (120)

(Variable-speed models only)

 

 

 

 

 

 

 

 

 

 

 

 

 

Medium extract, rpm (g)

695 (180)

630 (180)

594 (180)

594 (180)

550 (180)

543 (180)

(Variable-speed models only)

 

 

 

 

 

 

 

 

 

 

 

 

 

High extract, rpm (g)

803 (240)

727 (240)

686 (240)

686 (240)

565 (190)

627 (240)

 

(Variable-speed

(Variable-speed

 

 

 

 

 

models)

models)

 

 

 

 

 

492 (90)

482 (106)

 

 

 

 

 

(2-speed models)

(2-speed models)

 

 

 

 

 

 

 

 

 

 

 

Very High extract, rpm (g)

898 (300)

813 (300)

766 (300)

766 (300)

579 (200)

701 (300)

(Variable-speed models only)

 

 

 

 

 

 

 

 

 

 

 

 

 

Balance Detection

 

 

 

 

 

 

Vibration switch installed

STD (Variable-

speed models)

N/A (2-speed

models)

STD (Variable-

speed models)

N/A (2-speed

models)

STD

STD

STD

STD

Direct Steam Heating (Optional)

Steam inlet connection size,

0.5 (13)

0.5 (13)

0.5 (13)

0.5 (13)

0.75 (19)

0.75 (19)

in. (mm)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of steam inlets

 

1

1

1

1

1

1

 

 

 

 

 

 

 

 

Steam required to

LOW

2.1 (1.5)

3.3 (2.4)

4.6 (3.3)

5.7 (4.1)

6.7 (4.9)

8.3 (6.0)

raise bath temperature

 

 

 

 

 

 

 

MED

2.3 (1.7)

3.7 (2.6)

5.2 (3.8)

6.5 (4.7)

7.8 (5.6)

9.5 (6.9)

10°F, lb. (10°C, kg)

 

 

 

 

 

 

 

 

 

HIGH

2.7 (1.9)

4.1 (2.9)

6.1 (4.4)

7.6 (5.5)

9.1 (6.6)

11.1 (8.0)

 

 

 

 

 

 

 

 

Average consumption per

1.4 (21.4)

2.1 (33.4)

3.1 (48.4)

3.8 (60.4)

4.6 (72.0)

5.8 (91.0)

cycle, BHP (kg)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical Heating (Optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

Total

200V

10.8

19.1

28.6

28.6

N/A

N/A

electrical heating

 

 

 

 

 

 

 

240V

15.6

27.4

41.2

41.2

N/A

N/A

capacity,

kW (N/A for 2 speed

 

 

 

 

 

 

 

380V

9.8

17.2

17.2

17.2

34.4

N/A

models)

 

 

 

 

 

 

 

 

 

415V

11.7

20.5

20.5

20.5

41.0

N/A

 

 

 

 

 

 

 

 

 

480V

15.6

27.4

27.4

27.4

54.8

N/A

 

 

 

 

 

 

 

 

Number of electrical heating

6

6

9

9

12

N/A

elements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical heating element size,

2.6

4.2

4.2

4.2

4.2

N/A

kW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138601

Image 16
Contents Washer-Extractors Page Contents Explanation of Safety Messages Important Safety InstructionsSafety Information Safety Decals Operator Safety Environmental Conditions Safe Operating EnvironmentMachine Location Input and Output Services AC Inverter DriveIntroduction Model IdentificationReplacement Parts Customer ServiceDelivery Inspection Name plate Location0001 Model Number Familiarization Guide Models Starting 4/1/09 Weight And Shipping Information Wash Cylinder Information Door Opening Information Drive Train InformationDirect Steam Heating Optional Balance DetectionElectrical Heating Optional Overall width, in. mm MED Machine Dimensions Specifications and DimensionsCrush hazard Uwtv Models Through 3/31/09UW35TV UW125TV Models UW150TV Models Dimension 35 125 Models Models UW Design 3 Models starting 10/4/10 Refer to and Figure Base BA Base Overall PHM807N Machine Foundation Requirements Concrete Foundation Pad Installation Proceed to Machine Mounting and Grouting sectionLength for ONE Machine Floor Load Data 1272 1442 Speed 1745 2392 Speed 1797 2342 10.4 Mounting Bolt Installation Requirements Machine Mounting and Grouting Mounting Bolt Hole Locations Speed Models onlyVARIABLE-SPEED Model Front of Machine 80 / 100 Models 1181 mm 178 mm 254 mm Model Grout Placement 35 2-SPEED ModelGap Setting for Vibration Switch For UniLinc Models, Navigate to the Inputs Outputs MenuPound Model 60, 80, 100 and 125 Pound Models Design 1 150 Pound Model Drain Trough Configuration Drain Connection RequirementsDrain Information Specifications 100 125 150 Water Supply Information Specifications 80/100 125/150 Water ConnectionAir Cushions Risers Electrical Installation Requirements 50Hz ConversionDo not use a phase adder on any variable- speed machine Specifications and Dimensions Code CycleM30 Control Models only Steam Requirements Steam Heat Option Only Steam Supply Information 100 125/150Chemical Injection Supply System Connecting External Liquid Supplies to the Washer-Extractor Chemical Injection Supply SystemPHM553N External Supplies Chemical Injection Using Internal 24VAC Control Transformer Chemical injection Using External AC Power Source External Supply Signals ES1 Power supply Supply 1 Signal K1 Contact