Alliance Laundry Systems PHM802N, PHM798N manual Gap Setting for Vibration Switch

Page 40

Specifications and Dimensions

Gap Setting for Vibration Switch

After the machine has been properly installed, the vibration switch gap must be verified. To locate the vibration switch refer to Figures 18, 19 and 20. For UniLinc models, while the control is displaying the Inputs Outputs Menu the alarm will sound when the frame switch is activated. To verify and set the vibration switch gap use the following procedures:

WARNING

Only trained personnel should perform this procedure. Use caution while servicing machines with covers removed and power applied.

W700

For UniLinc Models, Navigate to the Inputs Outputs Menu:

1.From the Cycle Menu press and hold the

, , keys to enter the System Menu.

2.Press the arrow keys to highlight the Diagnostic box.

3.Press the key to enter the Diagnostic Menu.

4.Press the key to enter the Test Menu.

5.Press the arrow keys to highlight the Inputs Outputs box.

6.Press the key to enter the Inputs Outputs Menu.

Verify Vibration Switch Gap

(for 35-125 Pound Models):

1.Insert 0.009 inch feeler gauge between the adjustment bolt and the vibration switch; the alarm must not activate.

2.Remove the feeler gauge

3.Insert 0.010 inch feeler gauge (supplied with machine) between the adjustment bolt and the vibration switch; the alarm must activate.

4.Remove the feeler gauge.

5.Adjust the vibration switch adjustment bolt if necessary.

Verify Vibration Switch Gap

(For 150 Pound Design 1 Models):

1.Insert the 0.010 inch feeler gauge (supplied with machine) between the adjustment bolt and the vibration switch.

2.If alarm is active: Slowly loosen adjustment bolt until the alarm stops.

3.Very slowly tighten the adjustment bolt until the alarm activates. The adjustment bolt must be tightened very slowly to prevent over adjustment.

4.Remove the feeler gauge.

5.Verify the Frame Switch setting.

To adjust the vibration switch gap on the 150 models, move the vibration switch by adjusting the jam nuts on the vibration switch.

For UniLinc models, to return to the Cycle Menu press BACK key several times until Cycle Menu is displayed.

Verify Safety Switch Operation

(For 150 Pound Design 2 Models):

1.Place a large magnet above the normally-closed ball switch to verify switch operation.

IMPORTANT: UW150 Design 2 machines are manufactured with a normally-closed ball switch and should not require any adjustment. To avoid nuisance tripping, machine must be level with a summed value of 3/8 inch front to back and right to left to the earth. If switch is tripped, check if machine is level and then for pour grouting and broken anchor bolts. DO NOT BYPASS SAFETY SWITCH. Contact a qualified service technician for further assistance.

38

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138601

Image 40
Contents Washer-Extractors Page Contents Explanation of Safety Messages Important Safety InstructionsSafety Information Safety Decals Operator Safety Environmental Conditions Safe Operating EnvironmentMachine Location Input and Output Services AC Inverter DriveIntroduction Model IdentificationReplacement Parts Customer ServiceDelivery Inspection Name plate Location0001 Model Number Familiarization Guide Models Starting 4/1/09Weight And Shipping Information Wash Cylinder InformationDoor Opening Information Drive Train InformationDirect Steam Heating Optional Balance DetectionElectrical Heating Optional Overall width, in. mm MED Machine Dimensions Specifications and DimensionsCrush hazard Uwtv Models Through 3/31/09UW35TV UW125TV Models UW150TV Models Dimension 35 125 Models Models UW Design 3 Models starting 10/4/10 Refer to and Figure Base BA Base Overall PHM807N Machine Foundation Requirements Concrete Foundation Pad Installation Proceed to Machine Mounting and Grouting sectionLength for ONE Machine Floor Load Data 1272 1442 Speed 1745 2392 Speed 1797 2342 10.4 Mounting Bolt Installation Requirements Machine Mounting and Grouting Mounting Bolt Hole Locations Speed Models onlyVARIABLE-SPEED Model Front of Machine 80 / 100 Models 1181 mm 178 mm 254 mm Model Grout Placement 35 2-SPEED ModelGap Setting for Vibration Switch For UniLinc Models, Navigate to the Inputs Outputs MenuPound Model 60, 80, 100 and 125 Pound Models Design 1 150 Pound Model Drain Trough Configuration Drain Connection RequirementsDrain Information Specifications 100 125 150 Water Supply Information Specifications 80/100 125/150 Water ConnectionAir Cushions Risers Electrical Installation Requirements 50Hz ConversionDo not use a phase adder on any variable- speed machine Specifications and Dimensions Code CycleM30 Control Models only Steam Requirements Steam Heat Option Only Steam Supply Information 100 125/150Chemical Injection Supply System Connecting External Liquid Supplies to the Washer-Extractor Chemical Injection Supply SystemPHM553N External Supplies Chemical Injection Using Internal 24VAC Control Transformer Chemical injection Using External AC Power Source External Supply Signals ES1 Power supply Supply 1 Signal K1 Contact