Chemical injection Using External AC Power Source
NOTE: An External AC Power Source is NOT provided by Alliance Laundry Systems.
NOTE: Power for external supplies must not be derived from the
Specifications and Dimensions
IMPORTANT: The external power must supply power of 240VAC or less and be protected at 3 Amps or less.
1.Remove the red jumper wire installed by the factory between “24VAC”: and “RELAY COM”.
2.Connect one side of the external power to the “RELAY COM” and the other to the external dispenser input signals common. Refer to Figure 32.
|
|
| 3 |
| 1 |
|
|
|
|
| 4 |
|
| 2 |
|
|
|
| = Neutral |
|
|
| = Power |
|
|
| 5 |
|
|
| PHM823N |
1 | External Supply Power | 4 | VAC Power Terminal |
2 | Red Jumper Wire | 5 | VAC RETURN Terminal |
3 | External Supply Common |
|
|
Figure 32
CAUTION
Do not attempt to increase fuse rating or alter wiring of external chemical supply terminal strip in such as way that may conflict with the suggested methods provided on the Optional External Supply Wiring Diagram.
W699