Alliance Laundry Systems PHM802N, PHM798N manual Mounting Bolt Installation Requirements

Page 32

Specifications and Dimensions

Mounting Bolt Installation

Requirements

Approved Foundations Only

NOTE: If installing expansion bolts into an elevated concrete foundation pad, the concrete foundation pad should extend a minimum of 9 inches (229 mm) for 35 machines or 12 inches (305

mm)for 60 - 150 machines out from the machine base on all sides. Refer to Figure 9.

A bolt kit consisting of eight bolts is available as an option. 35 machines use 5/8-11 x 8 inch bolts.

60 – 125 machines use 3/4-10 x 8 inch bolts. 150 machines use 3/4-10 x 10 inch grade 5 bolts. The bolts should be embedded in a 3500 psi (241 bar) minimum reinforced concrete floor that is a minimum of 6 inches (153 mm) (for 35 and 60 2-speed, L-speed, and M-speed models) or a 12 inch (305 mm) (for all other models) thick. Use the mounting bolt layouts in Mounting Bolt Hole Locations section.

On 35 – 125 machines, the threaded end of the bolts should extend 2 inches (5.08 cm) above the mounting surface. On 150 machines, the threaded end of the bolts should extend 3 inches above the mounting surface.

Refer to Figure 10 for a typical installation of individual mounting bolts.

1

0.75 in.2

(19 mm)

2 in.

3

(51 mm)

 

8 in.

4

(203 mm)

For new foundations a bolt-locator fixture or rebar frame is available and a preferred option. This rigid welded assembly made of reinforcing rod and mounting bolts is designed to be embedded in concrete. Refer to Figure 11.

1

2

3

4

PHM179N

1Machine Frame Base

2Mounting Bolt Threads

3Grouting

4Reinforcing Rod

Figure 11

PHM722N

1Machine Frame Base

2Mounting Bolt Threads

3Grouting

4Cement or Structural Epoxy

Figure 10

30

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138601

Image 32
Contents Washer-Extractors Page Contents Explanation of Safety Messages Important Safety InstructionsSafety Information Safety Decals Operator Safety Machine Location Safe Operating EnvironmentEnvironmental Conditions Input and Output Services AC Inverter DriveIntroduction Model IdentificationReplacement Parts Customer ServiceDelivery Inspection Name plate Location0001 Model Number Familiarization Guide Models Starting 4/1/09Weight And Shipping Information Wash Cylinder InformationDoor Opening Information Drive Train InformationElectrical Heating Optional Balance DetectionDirect Steam Heating Optional Overall width, in. mm MED Machine Dimensions Specifications and DimensionsCrush hazard Uwtv Models Through 3/31/09UW35TV UW125TV Models UW150TV Models Dimension 35 125 Models Models UW Design 3 Models starting 10/4/10 Refer to and Figure Base BA Base Overall PHM807N Machine Foundation Requirements Concrete Foundation Pad Installation Proceed to Machine Mounting and Grouting sectionLength for ONE Machine Floor Load Data 1272 1442 Speed 1745 2392 Speed 1797 2342 10.4 Mounting Bolt Installation Requirements Machine Mounting and Grouting Mounting Bolt Hole Locations Speed Models onlyVARIABLE-SPEED Model Front of Machine 80 / 100 Models 1181 mm 178 mm 254 mm Model Grout Placement 35 2-SPEED ModelGap Setting for Vibration Switch For UniLinc Models, Navigate to the Inputs Outputs MenuPound Model 60, 80, 100 and 125 Pound Models Design 1 150 Pound Model Drain Trough Configuration Drain Connection RequirementsDrain Information Specifications 100 125 150 Water Supply Information Specifications 80/100 125/150 Water ConnectionAir Cushions Risers Electrical Installation Requirements 50Hz ConversionDo not use a phase adder on any variable- speed machine Specifications and Dimensions Code CycleM30 Control Models only Steam Requirements Steam Heat Option Only Steam Supply Information 100 125/150Chemical Injection Supply System Connecting External Liquid Supplies to the Washer-Extractor Chemical Injection Supply SystemPHM553N External Supplies Chemical Injection Using Internal 24VAC Control Transformer Chemical injection Using External AC Power Source External Supply Signals ES1 Power supply Supply 1 Signal K1 Contact