Alliance Laundry Systems PHM802N, PHM798N manual 1272 1442 Speed

Page 30

Specifications and Dimensions

UWL, UWN AND UWU Pocket Hardmount Floor Load Data (Models Starting 4/1/09)

Specifications

Design

Speed

35

60

80

100

125

150

 

Series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Static floor load,

U1 and

Variable-speed

1272

1442

2292

2490

3283

3936

lbs. (kN)

greater

 

(5.66)

(6.42)

(10.2)

(11.1)

(14.6)

(17.5)

 

 

 

 

 

 

 

 

 

 

 

2-speed

1272

1442

N/A

N/A

N/A

N/A

 

 

 

(5.66)

(6.42)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L-speed

1272

1442

N/A

N/A

N/A

N/A

 

 

 

(5.7)

(6.4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M-speed

1272

1442

2292

2490

3283

N/A

 

 

 

(5.7)

(6.4)

(10.2)

(11)

(14.6)

 

 

 

 

 

 

 

 

 

 

Static pressure,

U1 and

Variable-speed

169

162

184

199

205

202

lbs/ft2 (kN/m2)

greater

 

(8.08)

(7.7)

(8.79)

(9.6)

(9.8)

(9.7)

 

 

2-speed

169

162

N/A

N/A

N/A

N/A

 

 

 

(8.08)

(7.7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L-speed

169

162

N/A

N/A

N/A

N/A

 

 

 

(8)

(7.7)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M-speed

169

162

184

199

205

N/A

 

 

 

(8)

(7.7)

(8.8)

(9.5)

(9.8)

 

 

 

 

 

 

 

 

 

 

Dynamic floor load,

U1 and

Variable-speed

1576

2704

3603

4504

3746

4501

lbs. (kN)

greater

 

(7)

(12)

(16.36)

(16.41)

(22.29)

(19.4)

 

 

 

 

 

 

 

 

 

 

 

2-speed

473

950

N/A

N/A

N/A

N/A

 

 

 

(2.1)

(4.23)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L-speed

525

900

N/A

N/A

N/A

N/A

 

 

 

(2,3)

(4)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M-speed

944

1624

2167

2708

3380

N/A

 

 

 

(4.2)

(7.2)

(9.6)

(12)

(15)

 

 

 

 

 

 

 

 

 

 

Dynamic pressure,

U1 and

Variable-speed

380

466

472

559

439

433

lbs/ft2 (kN/m2)

greater

 

(18.2)

(22.34)

(22.63)

(26.8)

(21)

(20.8)

 

 

2-speed

233

269

N/A

N/A

N/A

N/A

 

 

 

(11.2)

(6.3)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L-speed

240

263

N/A

N/A

N/A

N/A

 

 

 

(11.5)

(12.59)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

M-speed

295

344

357

416

416

N/A

 

 

 

(14.1)

(16.5)

(17)

(19.9)

(19.9)

 

 

 

 

 

 

 

 

 

 

Dynamic load

U1 and

Variable-speed

15

13.6

12.8

12.8

9.7

11.7

frequency, Hz

greater

 

 

 

 

 

 

 

2-speed

8.2

8.0

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

L-speed

8.63

7.82

N/A

N/A

N/A

N/A

 

 

 

 

 

 

 

 

 

 

 

M-speed

11.58

10.5

9.9

9.9

9.2

N/A

 

 

 

 

 

 

 

 

 

 

 

 

Table 5 (continued)

 

 

 

 

28

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138601

Image 30
Contents Washer-Extractors Page Contents Explanation of Safety Messages Important Safety InstructionsSafety Information Safety Decals Operator Safety Safe Operating Environment Environmental ConditionsMachine Location Input and Output Services AC Inverter DriveIntroduction Model IdentificationDelivery Inspection Replacement PartsCustomer Service Name plate Location0001 Model Number Familiarization Guide Models Starting 4/1/09Door Opening Information Weight And Shipping InformationWash Cylinder Information Drive Train InformationBalance Detection Direct Steam Heating OptionalElectrical Heating Optional Overall width, in. mm MED Crush hazard Machine DimensionsSpecifications and Dimensions Uwtv Models Through 3/31/09UW35TV UW125TV Models UW150TV Models Dimension 35 125 Models Models UW Design 3 Models starting 10/4/10 Refer to and Figure Base BA Base Overall PHM807N Machine Foundation Requirements Concrete Foundation Pad Installation Proceed to Machine Mounting and Grouting sectionLength for ONE Machine Floor Load Data 1272 1442 Speed 1745 2392 Speed 1797 2342 10.4 Mounting Bolt Installation Requirements Machine Mounting and Grouting Mounting Bolt Hole Locations Speed Models onlyVARIABLE-SPEED Model Front of Machine 80 / 100 Models 1181 mm 178 mm 254 mm Model Grout Placement 35 2-SPEED ModelGap Setting for Vibration Switch For UniLinc Models, Navigate to the Inputs Outputs MenuPound Model 60, 80, 100 and 125 Pound Models Design 1 150 Pound Model Drain Trough Configuration Drain Connection RequirementsDrain Information Specifications 100 125 150 Water Supply Information Specifications 80/100 125/150 Water ConnectionAir Cushions Risers Electrical Installation Requirements 50Hz ConversionDo not use a phase adder on any variable- speed machine Specifications and Dimensions Code CycleM30 Control Models only Steam Requirements Steam Heat Option Only Steam Supply Information 100 125/150Chemical Injection Supply System Connecting External Liquid Supplies to the Washer-Extractor Chemical Injection Supply SystemPHM553N External Supplies Chemical Injection Using Internal 24VAC Control Transformer Chemical injection Using External AC Power Source External Supply Signals ES1 Power supply Supply 1 Signal K1 Contact