Alliance Laundry Systems PHM802N, PHM798N manual Water Connection

Page 46

Specifications and Dimensions

Water Connection

WARNING

To prevent personal injury, avoid contact with inlet water temperatures higher than 125° Fahrenheit (51° Celsius) and hot surfaces.

W748

Maximum water inlet temperature is 190° Fahrenheit (88° Celsius).

Water Supply Information

Specifications

35

 

60

80/100

125/150

Number of main fill water inlets

2

 

2

2

2

 

 

 

 

 

 

Main fill water inlet size, in. (mm)

3/4 (19)

 

3/4 (19)

3/4 (19)

1 (25.4)

Number of Spray Rinse water inlets

2

 

2

2

2

Spray rinse water inlet size, in. (mm)

3/4 (19)

 

3/4 (19)

3/4 (19)

3/4 (19)

 

 

 

 

 

 

Recommended pressure, psi (bar)

 

 

30 – 85 (2 – 5.7)

 

Inlet flow capacity (80 psi),

31 (117)

 

39 (148)

41 (155)

48 (182)

gal/min. (l/min)

 

 

 

 

 

 

 

Table 8

 

 

Connections should be supplied by hot and cold water lines of at least the sizes shown in the Water Supply Line Sizing table. Installation of additional machines will require proportionately larger water lines. Refer to Table 9. Flush the water lines before connecting them to the machine.

44

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138601

Image 46
Contents Washer-Extractors Page Contents Explanation of Safety Messages Important Safety InstructionsSafety Information Safety Decals Operator Safety Environmental Conditions Safe Operating EnvironmentMachine Location Input and Output Services AC Inverter DriveIntroduction Model IdentificationDelivery Inspection Replacement PartsCustomer Service Name plate Location0001 Model Number Familiarization Guide Models Starting 4/1/09Door Opening Information Weight And Shipping InformationWash Cylinder Information Drive Train InformationDirect Steam Heating Optional Balance DetectionElectrical Heating Optional Overall width, in. mm MED Crush hazard Machine DimensionsSpecifications and Dimensions Uwtv Models Through 3/31/09UW35TV UW125TV Models UW150TV Models Dimension 35 125 Models Models UW Design 3 Models starting 10/4/10 Refer to and Figure Base BA Base Overall PHM807N Machine Foundation Requirements Concrete Foundation Pad Installation Proceed to Machine Mounting and Grouting sectionLength for ONE Machine Floor Load Data 1272 1442 Speed 1745 2392 Speed 1797 2342 10.4 Mounting Bolt Installation Requirements Machine Mounting and Grouting Mounting Bolt Hole Locations Speed Models onlyVARIABLE-SPEED Model Front of Machine 80 / 100 Models 1181 mm 178 mm 254 mm Model Grout Placement 35 2-SPEED ModelGap Setting for Vibration Switch For UniLinc Models, Navigate to the Inputs Outputs MenuPound Model 60, 80, 100 and 125 Pound Models Design 1 150 Pound Model Drain Trough Configuration Drain Connection RequirementsDrain Information Specifications 100 125 150 Water Supply Information Specifications 80/100 125/150 Water ConnectionAir Cushions Risers Electrical Installation Requirements 50Hz ConversionDo not use a phase adder on any variable- speed machine Specifications and Dimensions Code CycleM30 Control Models only Steam Requirements Steam Heat Option Only Steam Supply Information 100 125/150Chemical Injection Supply System Connecting External Liquid Supplies to the Washer-Extractor Chemical Injection Supply SystemPHM553N External Supplies Chemical Injection Using Internal 24VAC Control Transformer Chemical injection Using External AC Power Source External Supply Signals ES1 Power supply Supply 1 Signal K1 Contact