Alliance Laundry Systems PHM802N, PHM798N manual M30 Control Models only

Page 52

Specifications and Dimensions

 

Voltage Designation

 

 

Non-Electric Heat

 

 

Electric Heat Machines

 

 

 

 

 

 

Machines (Standard)

 

 

 

 

Model

Code

Voltage

Cycle

Phase

Wire

FullLoad Amps

Breaker

*AWG

2

FullLoad Amps

Breaker

*AWG

2

 

 

 

 

 

 

 

 

 

*mm

 

 

 

*mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200 – 240

50/60

3

3

10

15

14

2.5

 

108

110

1

50

 

(Through

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4/13/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200 – 240

50/60

3

3

14

20

14

2.5

 

108

110

1

50

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4/14/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

380 – 480

50/60

3

3

10

15

14

2.5

 

40

50

6

16

100

(Through

 

 

 

 

 

 

 

 

 

 

 

 

 

10/1/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

440 – 480

50/60

3

3

10

15

14

2.5

 

40

50

6

16

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/4/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380 – 415

50/60

3

3

10

15

14

2.5

 

40

50

6

16

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/4/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200 – 240

50/60

3

3

9

15

14

2.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

380 – 480

50/60

3

3

8

15

14

2.5

 

NOT AVAILABLE

 

 

(Through

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/1/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

125

N

440 – 480

50/60

3

3

8

15

14

2.5

 

74

80

4

25

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/4/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380 – 415

50/60

3

3

8

15

14

2.5

 

65

70

4

25

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/4/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Q

200 – 240

50/60

3

3

16

20

12

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

R

380 – 480

50/60

3

3

11

15

14

2.5

 

 

 

 

 

 

(Through

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/1/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

150

N

440 – 480

50/60

3

3

11

15

14

2.5

 

NOT AVAILABLE

 

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/4/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P

380 – 415

50/60

3

3

11

15

14

2.5

 

 

 

 

 

 

(Starting

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10/4/10)

 

 

 

 

 

 

 

 

 

 

 

 

 

*NOTE: Wire sizing listed in this table is based on Article 310, Table 310.16 of the NEC; at 104°F (40°C) ambient temperature. Follow your local electrical codes. Use only copper conductors, rated for 194ºF (90°C) or higher, type THHN or better. No more than three current carrying conductors per raceway. Contact your local Authority having jurisdiction if you have questions. Circuit breakers should be UL 489 listed or better. Single phase circuit breakers for single phase machines only; three phase circuit breakers for all others.

**M30 Control Models only.

Table 10

50

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8138601

Image 52
Contents Washer-Extractors Page Contents Explanation of Safety Messages Important Safety InstructionsSafety Information Safety Decals Operator Safety Environmental Conditions Safe Operating EnvironmentMachine Location Input and Output Services AC Inverter DriveIntroduction Model IdentificationReplacement Parts Customer ServiceDelivery Inspection Name plate Location0001 Model Number Familiarization Guide Models Starting 4/1/09Weight And Shipping Information Wash Cylinder InformationDoor Opening Information Drive Train InformationDirect Steam Heating Optional Balance DetectionElectrical Heating Optional Overall width, in. mm MED Machine Dimensions Specifications and DimensionsCrush hazard Uwtv Models Through 3/31/09UW35TV UW125TV Models UW150TV Models Dimension 35 125 Models Models UW Design 3 Models starting 10/4/10 Refer to and Figure Base BA Base Overall PHM807N Machine Foundation Requirements Concrete Foundation Pad Installation Proceed to Machine Mounting and Grouting sectionLength for ONE Machine Floor Load Data 1272 1442 Speed 1745 2392 Speed 1797 2342 10.4 Mounting Bolt Installation Requirements Machine Mounting and Grouting Mounting Bolt Hole Locations Speed Models onlyVARIABLE-SPEED Model Front of Machine 80 / 100 Models 1181 mm 178 mm 254 mm Model Grout Placement 35 2-SPEED ModelGap Setting for Vibration Switch For UniLinc Models, Navigate to the Inputs Outputs MenuPound Model 60, 80, 100 and 125 Pound Models Design 1 150 Pound Model Drain Trough Configuration Drain Connection RequirementsDrain Information Specifications 100 125 150 Water Supply Information Specifications 80/100 125/150 Water ConnectionAir Cushions Risers Electrical Installation Requirements 50Hz ConversionDo not use a phase adder on any variable- speed machine Specifications and Dimensions Code CycleM30 Control Models only Steam Requirements Steam Heat Option Only Steam Supply Information 100 125/150Chemical Injection Supply System Connecting External Liquid Supplies to the Washer-Extractor Chemical Injection Supply SystemPHM553N External Supplies Chemical Injection Using Internal 24VAC Control Transformer Chemical injection Using External AC Power Source External Supply Signals ES1 Power supply Supply 1 Signal K1 Contact