Machine Mounting and Grouting

After the concrete has cured, proceed as follows:

1.Place the washer-extractor adjacent to the foundation. Do not attempt to move the machine by pushing on the sides. Always insert a pry bar or other device under the bottom frame of the machine to move it.

2.Remove the wood skid by unscrewing the carriage bolts holding the skid to the bottom frame of the washer-extractor.

3.Place the washer-extractor carefully over the anchor bolts. Never attempt to lift the machine by the door handle or by pushing on the cover panels.

4.Raise and level the washer-extractor 0.5 inch (1.27 cm) off the floor on three points, using spacers such as nut fasteners.

5.Fill the space between the washer-extractor base and the floor with a good quality non-shrinking machinery precision grout to ensure a stable installation. Grout completely under all frame members. (Remove front panel and back panel to gain access to all frame members.) Refer to Figure 17. Force grout under machine base until all voids are filled.

6.Remove the spacers carefully, allowing the machine to settle into the wet grout.

Specifications and Dimensions

7.Before grout sets completely, make a drain opening in the rear of the washer-extractor grouting with a stiff piece of wire; this opening should be approximately 1/2 inch (1.27 cm) wide to allow any surface water build-up under the base of the machine to drain away. Do not omit this step.

8.Position the mounting bolt lockwashers and locknuts on the anchor bolts and finger-tighten locknuts to machine base.

9.After the grout is completely dry, tighten the locknuts by even increments – one after the other – until all are tightened evenly and the washer- extractor is fastened securely to the floor.

10.After installing bolts using a rebar frame, torque 5/8 inch bolts (35 model) to 90 ft. lb. and torque 3/4 inch bolts (60-150 models) to 160 ft. lb.

When using bolts not specified by Alliance Laundry Systems, refer to the specifications provided with the bolt.

NOTE: Check and retighten the locknuts after five to ten days of operation and every month thereafter.

F8138601

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

31

Image 33
Contents Washer-Extractors Page Contents Important Safety Instructions Explanation of Safety MessagesSafety Information Safety Decals Operator Safety Safe Operating Environment Environmental ConditionsMachine Location AC Inverter Drive Input and Output ServicesModel Identification IntroductionCustomer Service Replacement PartsDelivery Inspection Name plate LocationModel Number Familiarization Guide Models Starting 4/1/09 0001Wash Cylinder Information Weight And Shipping InformationDoor Opening Information Drive Train InformationBalance Detection Direct Steam Heating OptionalElectrical Heating Optional Overall width, in. mm MED Specifications and Dimensions Machine DimensionsCrush hazard Uwtv Models Through 3/31/09UW35TV UW125TV Models UW150TV Models Dimension 35 125 Models Models UW Design 3 Models starting 10/4/10 Refer to and Figure Base BA Base Overall PHM807N Machine Foundation Requirements Proceed to Machine Mounting and Grouting section Concrete Foundation Pad InstallationLength for ONE Machine Floor Load Data 1272 1442 Speed 1745 2392 Speed 1797 2342 10.4 Mounting Bolt Installation Requirements Machine Mounting and Grouting Speed Models only Mounting Bolt Hole LocationsVARIABLE-SPEED Model Front of Machine 80 / 100 Models 1181 mm 178 mm 254 mm Model 35 2-SPEED Model Grout PlacementFor UniLinc Models, Navigate to the Inputs Outputs Menu Gap Setting for Vibration SwitchPound Model 60, 80, 100 and 125 Pound Models Design 1 150 Pound Model Drain Connection Requirements Drain Trough ConfigurationDrain Information Specifications 100 125 150 Water Connection Water Supply Information Specifications 80/100 125/150Air Cushions Risers 50Hz Conversion Electrical Installation RequirementsDo not use a phase adder on any variable- speed machine Specifications and Dimensions Cycle CodeM30 Control Models only Steam Supply Information 100 125/150 Steam Requirements Steam Heat Option OnlyChemical Injection Supply System Chemical Injection Supply System Connecting External Liquid Supplies to the Washer-ExtractorPHM553N External Supplies Chemical Injection Using Internal 24VAC Control Transformer Chemical injection Using External AC Power Source External Supply Signals ES1 Power supply Supply 1 Signal K1 Contact