Alliance Laundry Systems PHM1263R manual SAT FRI Thur WED TUE MON SUN

Page 26

Programming Control

Table 4 (continued)

Day(s) of the Week Enabled Values

Day Of Week

SAT

FRI

THUR

WED

TUE

MON

SUN

Value

 

 

 

 

 

 

 

40

OFF

ON

OFF

ON

OFF

OFF

OFF

41

OFF

ON

OFF

ON

OFF

OFF

ON

42

OFF

ON

OFF

ON

OFF

ON

OFF

43

OFF

ON

OFF

ON

OFF

ON

ON

44

OFF

ON

OFF

ON

ON

OFF

OFF

45

OFF

ON

OFF

ON

ON

OFF

ON

46

OFF

ON

OFF

ON

ON

ON

OFF

47

OFF

ON

OFF

ON

ON

ON

ON

48

OFF

ON

ON

OFF

OFF

OFF

OFF

49

OFF

ON

ON

OFF

OFF

OFF

ON

50

OFF

ON

ON

OFF

OFF

ON

OFF

51

OFF

ON

ON

OFF

OFF

ON

ON

52

OFF

ON

ON

OFF

ON

OFF

OFF

53

OFF

ON

ON

OFF

ON

OFF

ON

54

OFF

ON

ON

OFF

ON

ON

OFF

55

OFF

ON

ON

OFF

ON

ON

ON

56

OFF

ON

ON

ON

OFF

OFF

OFF

57

OFF

ON

ON

ON

OFF

OFF

ON

58

OFF

ON

ON

ON

OFF

ON

OFF

59

OFF

ON

ON

ON

OFF

ON

ON

60

OFF

ON

ON

ON

ON

OFF

OFF

61

OFF

ON

ON

ON

ON

OFF

ON

62

OFF

ON

ON

ON

ON

ON

OFF

63

OFF

ON

ON

ON

ON

ON

ON

64

ON

OFF

OFF

OFF

OFF

OFF

OFF

65

ON

OFF

OFF

OFF

OFF

OFF

ON

66

ON

OFF

OFF

OFF

OFF

ON

OFF

67

ON

OFF

OFF

OFF

OFF

ON

ON

68

ON

OFF

OFF

OFF

ON

OFF

OFF

69

ON

OFF

OFF

OFF

ON

OFF

ON

70

ON

OFF

OFF

OFF

ON

ON

OFF

71

ON

OFF

OFF

OFF

ON

ON

ON

72

ON

OFF

OFF

ON

OFF

OFF

OFF

73

ON

OFF

OFF

ON

OFF

OFF

ON

74

ON

OFF

OFF

ON

OFF

ON

OFF

75

ON

OFF

OFF

ON

OFF

ON

ON

76

ON

OFF

OFF

ON

ON

OFF

OFF

77

ON

OFF

OFF

ON

ON

OFF

ON

78

ON

OFF

OFF

ON

ON

ON

OFF

79

ON

OFF

OFF

ON

ON

ON

ON

80

ON

OFF

ON

OFF

OFF

OFF

OFF

81

ON

OFF

ON

OFF

OFF

OFF

ON

82

ON

OFF

ON

OFF

OFF

ON

OFF

83

ON

OFF

ON

OFF

OFF

ON

ON

Table 4 (continued)

24

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8208801

Image 26
Contents Washer-Extractor Page W030 Contents Temperature Controlled Fill Enable/Disable tCF Model Identification About the Control Power Failure RecoveryPreliminary Information Glossary of TermsControl Identification Select Cycle Pads Refer to FigureFour 7-Segment Digits Display IdentificationLight Emitting Diodes LEDs Refer to Figure Washer-Extractor Operation Special Features Manual Diagnostics Entering the Manual ModeHow to Enter the Manual Mode Manual ProgrammingWhat Can Be Programmed? Option Description Default Value Range Number DisplayProgramming Control Programmable Options AvailableCoLd/Uarn/Hotor FLEnTEnP SUEnProgramming Control Manual Mode Flowchart Manual Programming Flowchart 1 Manual Programming Flowchart 2 Manual Programming Flowchart 3 Option available on software version 2 onlyDiagnostic Tests Flowchart How to Exit Programming Feature Default Cycle dCYCHow to Program Default Cycle Audio Signal AUd How to Program the Audio SignalRemove Coin How to Read TableMode Card End Key Input Not Cycle Pressed UsedLEr3 Error Code Programming ErrHow to Program Error Code Programming ESdSAT FRI Thur WED TUE MON SUN SAT FRI Thur WED TUE MON SUN OFF Cycle Programming Cy How to Enter Cycle ProgrammingHow to Program Cycle Agitate AgIt Final Description StatusHow to Program Cycle Segment SEg1 Fill Step Description StatusStep SupplyDescription Status/Value Agitate Description Status/Value StepProgramming Drain Step Extract DescriptionHow to Program Number of Balance Retries Programming Cycle Time DisplayHow to Program Fahrenheit/Celsius IR Access On/Off IrAHow to Program the IR Access On/Off Fahrenheit/Celsius t FCHow to Program Hot Water Temperature Hot Water Temperature FHWarm Water Temperature FHC How to Program Warm Water TemperatureHow to Program Cold Water Temperature Cold Water Temperature FCCooldown Enable/Temperature Codn How to Program Cooldown Enable/ TemperatureProduction Test Cycle On/Off PtEn How to Program the Production Test Cycle On/OffHow to Program the Manual Rapid Advance On/Off Manual Rapid Advance On/Off rAEnNo Cycle Time Display nCtd How to Program in the Cycle Time DisplayHow to Program the Programmable Cycle Time Display Programmable Cycle Time Display PCtdSlow Drain Detection Adjust SdAd How to Program the Pause/Resume ModeHow to Program the Time and Date Set Real-Time Clock rtC-’How to Program Low Water Level Manual Diagnostics On/Off dAEnHow to Program the Manual Diagnostics On/Off Low Water Level FLoMedium Water Level FnEd How to Program Medium Water LevelHow to Program High Water Level High Water Level FHITemperature Controlled Fill Enable/Disable tCF How to Program Temperature Controlled FillHow to Program Auto-Water Leak Detection Auto-Water Leak Detection ALdHow to Exit Audit Feature How to Enter Audit FeatureHow to Read Audit Data Collecting Audit InformationManual Reset How to Enter Manual ResetHow to Start Tests Testing Machine Electronic Control FunctionsHow to Enter Testing Feature How to Exit Testing FeatureD003 D001D002 TxxxDiagnostic Test Descriptions VFD Drive Fault Input Test Temperature Sensor Display TestVAC Switch Input Test Frame Balance Switch Input TestProduction Test Cycle Production Test Cycle Quick Reference Chart Display Test Cycle Step CommentsRAg then LoAg thenAg then DrAI thenError Codes Error Codes DoorHow to Exit Rapid Advance Feature Rapid Advance FeatureHow to Use Rapid Advance Infra-red Communications Communications ModeHow to Begin Communications with An External Device Default Cycles Default Cycles Cycle Stops Reclaim Delicates 90C 60C 40C 90C Perm 60C Perm Cycle reference CY08 CY09 Cycle Stops 40C Perm 70C Perm 50C Gentle 30C Gentle Blank CY17 CY18