Alliance Laundry Systems Complete Guide to Error Codes for Washers

Page 54

Error Codes

 

 

Table 16 (continued)

 

 

 

 

Display

Description

 

Cause/

 

Corrective Action

 

 

 

E dL

Door Lock Error

 

Door does not lock immeadiately upon closing (open and

 

 

 

reclose door) or doesn’t unlock 5 seconds after cycle

 

 

 

completion. Power down machine and retry.

 

 

 

 

E do

Door Open Error

 

Control detects door open. Caused by pulling on door while

 

 

 

locked or about to lock. Correct inoperative door locking

 

 

 

system. End cycle. Power down machine to clear.

 

 

 

 

E Ub

Unbalance Error

 

Unable to balance load. Redistribute load and run cycle.

 

 

 

 

door

Door Open Indicator

 

Door is not closed in Start Mode. If door is closed, check for

 

 

 

improper wiring or faulty door switch.

 

 

 

 

E dr

Drain Alarm Error

 

Machine not drained within 15 minutes (or other programmed

 

 

 

length of time) in any drain step. End cycle. Power down

 

 

 

machine to clear.

 

 

 

 

E Ht

Heat Alarm Error

 

Programmed heat alarm time of 120 minutes or other

 

 

 

programmed length of time is exceeded. Turns off heater

 

 

 

output for remainder of cycle.

 

 

 

 

E oP

Open Temperature Sensor Error

 

Control senses temperature less than 0°F (-18°C) in machine

 

 

 

equipped with temperature sensor. Heater and thermistor

 

 

 

related operations are disabled.

 

 

 

 

E SH

Shorted Temperature Sensor Error

 

Control senses temperature greater than 220°F (104°C) in

 

 

 

machine equipped with temperature sensor. Heater and

 

 

 

thermistor related operations are disabled for remainder of

 

 

 

cycle.

 

 

 

 

E ro

Rotation Sensor Error

 

Invalid signal received from Rotation Sensor. Control will

 

 

 

activate coast times to complete cycle.

 

 

 

 

E FS

Frame Balance Switch Error

 

Control detects Frame Balance Switch open. End cycle.

 

 

 

 

E db

Drive Balance Switch Error

 

Control detects VFD Balance Switch input closed at start of

 

 

 

drain step. End cycle. Power down machine to clear.

 

 

 

 

E Ld

Water Leak Detection Error

 

If control senses a drop in water level during diagnostic

 

 

 

testing, power down machine to clear. When error occurs

 

 

 

during a cycle, “E Ld” is displayed for one minute after

 

 

 

opening the door at the end of the cycle. When the error

 

 

 

occurs during the test, “E Ld” is displayed immediately after

 

 

 

the test until the machine is powered down to clear the error.

 

 

 

 

ESd

Slow Drain Error

 

If control shows error after door is open (when cycle is

 

 

 

completed) for one minute, the error information will be

 

 

 

logged in audit data.

 

 

 

 

 

 

Table 16

52

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8208801

Image 54
Contents Washer-Extractor Page W030 Contents Temperature Controlled Fill Enable/Disable tCF Model Identification About the Control Power Failure RecoveryPreliminary Information Glossary of TermsControl Identification Select Cycle Pads Refer to FigureDisplay Identification Light Emitting Diodes LEDs Refer to FigureFour 7-Segment Digits Washer-Extractor Operation Special Features Manual Diagnostics Entering the Manual ModeHow to Enter the Manual Mode Manual ProgrammingWhat Can Be Programmed? Option Description Default Value Range Number DisplayProgramming Control Programmable Options AvailableCoLd/Uarn/Hotor FLEnTEnP SUEnProgramming Control Manual Mode Flowchart Manual Programming Flowchart 1 Manual Programming Flowchart 2 Manual Programming Flowchart 3 Option available on software version 2 onlyDiagnostic Tests Flowchart Default Cycle dCYC How to Program Default CycleHow to Exit Programming Feature Audio Signal AUd How to Program the Audio SignalRemove Coin How to Read TableMode Card End Key Input Not Cycle Pressed UsedLEr3 Error Code Programming ErrHow to Program Error Code Programming ESdSAT FRI Thur WED TUE MON SUN SAT FRI Thur WED TUE MON SUN OFF Cycle Programming Cy How to Enter Cycle ProgrammingHow to Program Cycle Agitate AgIt Final Description StatusHow to Program Cycle Segment SEg1 Fill Step Description StatusStep SupplyDescription Status/Value Agitate Description Status/Value StepProgramming Drain Step Extract DescriptionHow to Program Number of Balance Retries Programming Cycle Time DisplayHow to Program Fahrenheit/Celsius IR Access On/Off IrAHow to Program the IR Access On/Off Fahrenheit/Celsius t FCHow to Program Hot Water Temperature Hot Water Temperature FHWarm Water Temperature FHC How to Program Warm Water TemperatureHow to Program Cold Water Temperature Cold Water Temperature FCCooldown Enable/Temperature Codn How to Program Cooldown Enable/ TemperatureProduction Test Cycle On/Off PtEn How to Program the Production Test Cycle On/OffHow to Program the Manual Rapid Advance On/Off Manual Rapid Advance On/Off rAEnNo Cycle Time Display nCtd How to Program in the Cycle Time DisplayHow to Program the Programmable Cycle Time Display Programmable Cycle Time Display PCtdSlow Drain Detection Adjust SdAd How to Program the Pause/Resume ModeHow to Program the Time and Date Set Real-Time Clock rtC-’How to Program Low Water Level Manual Diagnostics On/Off dAEnHow to Program the Manual Diagnostics On/Off Low Water Level FLoMedium Water Level FnEd How to Program Medium Water LevelHow to Program High Water Level High Water Level FHITemperature Controlled Fill Enable/Disable tCF How to Program Temperature Controlled FillHow to Program Auto-Water Leak Detection Auto-Water Leak Detection ALdHow to Exit Audit Feature How to Enter Audit FeatureHow to Read Audit Data Collecting Audit InformationManual Reset How to Enter Manual ResetHow to Start Tests Testing Machine Electronic Control FunctionsHow to Enter Testing Feature How to Exit Testing FeatureD003 D001D002 TxxxDiagnostic Test Descriptions VFD Drive Fault Input Test Temperature Sensor Display TestVAC Switch Input Test Frame Balance Switch Input TestProduction Test Cycle Production Test Cycle Quick Reference Chart Display Test Cycle Step CommentsRAg then LoAg thenAg then DrAI thenError Codes Error Codes DoorRapid Advance Feature How to Use Rapid AdvanceHow to Exit Rapid Advance Feature Communications Mode How to Begin Communications with An External DeviceInfra-red Communications Default Cycles Default Cycles Cycle Stops Reclaim Delicates 90C 60C 40C 90C Perm 60C Perm Cycle reference CY08 CY09 Cycle Stops 40C Perm 70C Perm 50C Gentle 30C Gentle Blank CY17 CY18