Alliance Laundry Systems PHM1263R manual Special Features

Page 11

Special Features

Programming Control

The control allows the washer-extractor owner to program the control with the use of the keypad. Cycle options may be programmed, audit information may be viewed and diagnostic tests may be run by pressing combinations of the select cycle keypads.

For details on programming select cycle options, refer to Programming Control.

Collecting Audit Information

The control will store audit information in its memory that can be retrieved by pressing various combinations of Select Cycle keypads. The control will record total machine cycles.

For more information on the audit features, refer to Collecting Audit Information.

NOTE: Additional audit information is retrievable with an external device, using infra-red communications. Refer to the appropriate instruction manual.

Testing Machine and Control Functions

Special diagnostic features built into the control allow the owner to run specific diagnostic tests. By opening and closing the access panel and then pressing various sequences of Select Cycle keypads, the owner may retrieve or perform the following tests:

Front End Control Software Version Number

Output Board Control Software Version Number

Output Board Water Level Sensor Trim Value

Access Panel Opening Test

Door Switch Input Test

Door Lock Input Test

Show Fill Time Test

Show Drain Time Test

Temperature Sensor Display Test

Start Pulse Test

VFD Balance Input Test

24 VAC Switch Input Test

VFD Drive Fault Input Test

Frame Balance Switch Input Test

VFD Balance Weight Test

Water Purge Test

Water Leak Detection test

For detailed information on running diagnostic tests, refer to Testing Machine and Control Functions.

Rapid Advance Feature

This feature allows the user to quickly advance through active cycles. This feature is useful when tests must be performed immediately on a washer-extractor currently in an active cycle. In this case, the user can quickly advance through the cycles to shakeout. At this point, the user can perform the required tests and then return the washer-extractor to the point it was interrupted.

For detailed information on using the Rapid Advance feature, refer to Rapid Advance Feature.

Communications Mode

This feature allows the control to communicate with an external device using infra-red communications. This allows the control to be programmed and have its data read without using the keypad.

For more detailed information on using the Communications Mode feature, refer to Communications Mode.

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

9

Image 11
Contents Washer-Extractor Page W030 Contents Temperature Controlled Fill Enable/Disable tCF Model Identification Glossary of Terms Power Failure RecoveryPreliminary Information About the ControlSelect Cycle Pads Refer to Figure Control IdentificationFour 7-Segment Digits Display IdentificationLight Emitting Diodes LEDs Refer to Figure Washer-Extractor Operation Special Features Manual Programming Entering the Manual ModeHow to Enter the Manual Mode Manual DiagnosticsProgrammable Options Available Option Description Default Value Range Number DisplayProgramming Control What Can Be Programmed?SUEn FLEnTEnP CoLd/Uarn/HotorProgramming Control Manual Mode Flowchart Manual Programming Flowchart 1 Manual Programming Flowchart 2 Option available on software version 2 only Manual Programming Flowchart 3Diagnostic Tests Flowchart How to Exit Programming Feature Default Cycle dCYCHow to Program Default Cycle How to Program the Audio Signal Audio Signal AUdNot Cycle Pressed Used How to Read TableMode Card End Key Input Remove CoinESd Error Code Programming ErrHow to Program Error Code Programming LEr3SAT FRI Thur WED TUE MON SUN SAT FRI Thur WED TUE MON SUN OFF Final Description Status How to Enter Cycle ProgrammingHow to Program Cycle Agitate AgIt Cycle Programming CyFill Step Description Status How to Program Cycle Segment SEg1Agitate Description Status/Value Step SupplyDescription Status/Value StepExtract Description Programming Drain StepProgramming Cycle Time Display How to Program Number of Balance RetriesFahrenheit/Celsius t FC IR Access On/Off IrAHow to Program the IR Access On/Off How to Program Fahrenheit/CelsiusHow to Program Warm Water Temperature Hot Water Temperature FHWarm Water Temperature FHC How to Program Hot Water TemperatureHow to Program Cooldown Enable/ Temperature Cold Water Temperature FCCooldown Enable/Temperature Codn How to Program Cold Water TemperatureManual Rapid Advance On/Off rAEn How to Program the Production Test Cycle On/OffHow to Program the Manual Rapid Advance On/Off Production Test Cycle On/Off PtEnProgrammable Cycle Time Display PCtd How to Program in the Cycle Time DisplayHow to Program the Programmable Cycle Time Display No Cycle Time Display nCtdHow to Program the Pause/Resume Mode Slow Drain Detection Adjust SdAdSet Real-Time Clock rtC-’ How to Program the Time and DateLow Water Level FLo Manual Diagnostics On/Off dAEnHow to Program the Manual Diagnostics On/Off How to Program Low Water LevelHigh Water Level FHI How to Program Medium Water LevelHow to Program High Water Level Medium Water Level FnEdHow to Program Temperature Controlled Fill Temperature Controlled Fill Enable/Disable tCFAuto-Water Leak Detection ALd How to Program Auto-Water Leak DetectionCollecting Audit Information How to Enter Audit FeatureHow to Read Audit Data How to Exit Audit FeatureHow to Enter Manual Reset Manual ResetHow to Exit Testing Feature Testing Machine Electronic Control FunctionsHow to Enter Testing Feature How to Start TestsTxxx D001D002 D003Diagnostic Test Descriptions Frame Balance Switch Input Test Temperature Sensor Display TestVAC Switch Input Test VFD Drive Fault Input TestProduction Test Cycle Display Test Cycle Step Comments Production Test Cycle Quick Reference ChartDrAI then LoAg thenAg then RAg thenError Codes Door Error CodesHow to Exit Rapid Advance Feature Rapid Advance FeatureHow to Use Rapid Advance Infra-red Communications Communications ModeHow to Begin Communications with An External Device Default Cycles Default Cycles Cycle Stops Reclaim Delicates 90C 60C 40C 90C Perm 60C Perm Cycle reference CY08 CY09 Cycle Stops 40C Perm 70C Perm 50C Gentle 30C Gentle Blank CY17 CY18