Programming Control
Manual Programming Flowchart (3 of 3)
(continued)
“bALr” (VFD only) - Program the number of times control will retry balancing the load before moving to extract step:
“IrA” - Enable/disable the ability to read
the control by an external device:
“on” = Enabled “off” = Disabled.
“t FC” (Temp Sensor only) - Set
temperature shown in Fahrenheit or Celsius.
“FH” (Temp Sensor only) - Set the temperature of the hot water: 35°F - 194°F / 2°C - 90°C.
“FHC” (Temp Sensor only) - Set the
temperature of the warm water:
35°F - 194°F / 2°C - 90°C.
“FC” (Temp Sensor only) - Set the
temperature of the cold water:
35°F - 194°F / 2°C - 90°C.
“Codn” (Temp Sensor only) - Enable/disable the cool down water temperature option:
“off” or 50°F - 160°F / 10°C - 71°C.
“PtEn” - Enable/disable access to the
production test cycle:
“on” = Enabled “off” = Disabled.
“rAEn” - Enable/disable the rapid advance
feature:
“on” = Enabled “off” = Disabled.
“nCtd” - Enable/disable whether the cycle
time will appear in display:
“on” = Enabled “off” = Disabled.
“PCtd” * - When enabled, the control displays the programmed time during a machine cycle:
“0” = Disabled “1” = Enabled
“SdAd” - Enable/disable slow drain
detection. When enabled can
increase/decrease the time before a slow
drain error will occur:
0 - 255 seconds
“dAEn” - Enable/disable the manual
diagnostics option:
“on” = Enabled “off” = Disabled.
“FLo” - Program the low water level during fill and tumble of all cycles:
“1” - “10”
“FnEd” - Program the medium water level
during fill and tumble of all cycles:
“11” - “20”
“FHI” - Program the high water level during
fill and tumble of all cycles:
“21” - “30”
“tCF” (Temp Sensor only) - Enable/disable a
temperature controlled fill:
“on” = Enabled “off” = Disabled.
* Option available on software version 2 only.
Temperature:
“CEL” = Celsius
“FAHr” = Fahrenheit
“rtC1” - Programs minutes:
“0” - “59”
“rtC2” - Programs Hours:
“0” - “23”
“rtC3” - Programs Day of Week:
“1” - “7”
“rtC4” - Programs Date of Month:
“1” - “31”
“rtC5” - Programs Month:
“1” - “12”
“rtC6” - Programs Year:
“0” - “99”
“rtC7” - Programs Daylight Saving:
“on” = Enabled
“oFF” = Disabled
“ALd1” -
“on”, then “0” - “127”
“oFF”
“ALd2”” -
Hour:
“0” - “23”
“ALd3” -
Day of Week:
“0” - “127”
PHM1400R
PHM1400R
Figure 5