23.Auto-Water Leak Detection “ALd”
This option allows the owner to set the time and frequency that the control automatically checks the water level. The owner programs which day(s) of the week and hours of day(s) they want this test to occur. The owner may also program this test to only occur after XX number of machine cycles have been completed since the last time the test was run. In order for this
How to Program Auto-Water Leak Detection
1.Control must be in Manual Mode. Refer to Entering the Manual Mode.
2.Press the #3 (>) or the #6 (<) keypad until
“Prog” appears in the display. Press the START (enter) keypad and “dCyC” will appear in the display.
3.Press the #3 (>) or the #6 (<) keypad to scroll through the programmable options until
4.Press the #3 (>) or the #6 (<) keypad to scroll through the programmable options. Refer to Table 11.
“ALd1” | |
| (“oFF” or “0” through “127” cycles |
| [on] - Number of completed cycles |
| after which this test will occur) |
|
|
“ALd2” | |
| (“0” - “23” - Hour of the day this |
| test will occur) |
|
|
“ALd3” | |
| Day of Week |
| (“0” - “127” - Refer to Table 4) |
|
|
| Table 11 |
Programming Control
5.When the desired option appears in the display, press the START (enter) keypad. The current value will appear in the display.
6.Press the #3 (>) or the #6 (<) keypad to enable during cycles, disable, increase or decrease the hours or day.
NOTE: The hours will be displayed in military time. For day, Sunday is considered day one (001), Monday is day two (002) and so on.
7.Press the START (enter) keypad when the correct value appears in the display. The next option, “dCyC” will appear in the display.
NOTE: To program “dCyC” (Default Cycle), refer to option 1. To program other options, refer to the appropriate section.
How to Exit Programming Feature
Press the #5 (<) keypad until the control returns to Ready Mode.
F8208801 | © Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT | 41 |