Alliance Laundry Systems PHM1263R manual Supply, Description Status/Value, Step

Page 30

Programming Control

Programming Supply Step

1.When “SUPL” appears in the display, press the START (enter) keypad. The first Supply step programming option will appear in the display.

2.Press the #3 (>) or the #6 (<) keypad to scroll through the programmable Supply step options. Refer to Table 7.

NOTE: Supply Step “SUEn” must be enabled to scroll through all Supply Step options.

3.Press the START (enter) keypad when the desired option appears in the display. The current status value will appear in the display. Refer to Table 7.

Supply

Description

Status/Value

Step

 

 

 

 

 

“SUEn”

Supply Step

“on”/“oFF”

 

Enable/Disable

 

 

 

 

“dISP”

Dispenser Options

Press START (enter) to

 

 

access options

 

 

 

“S1”

Supply #1

“on”/“oFF”

 

 

 

“S2”

Supply #2

“on”/“oFF”

 

 

 

“S3”

Supply #3

“on”/“oFF”

 

 

 

“S4”

Supply #4

“on”/“oFF”

 

 

 

“SdUr”

Supply Duration

Press START (enter)

 

 

to access options

 

 

 

“SEC”

Seconds

0-59

 

 

 

“nIn”

Minutes

0-9

 

 

 

 

Table 7

 

4.Press the #3 (>) or the #6 (<) keypad to change the current status/value.

5.Press the START (enter) keypad when the desired status/value appears in the display. The next Supply step option will appear in the display.

NOTE: To program “AgSt” (Agitate Step), continue to next Cycle Segment option. If in the Dispenser Options or Supply Duration programming option, press the #5 (<) keypad first. To program other options, press the #3 (>) or the #6 (<) keypad and refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to Ready Mode.

Programming Agitate Step

1.When “AgSt” appears in the display, press the START (enter) keypad. The first Agitate step programming option will appear in the display.

2.Press the #3 (>) or the #6 (<) keypad to scroll through the programmable Agitate step options. Refer to Table 8.

NOTE: Agitate Step “AgEn” must be enabled to scroll through all Agitate step options.

3.Press the START (enter) keypad when the desired option appears in the display. The current status/value will appear in the display. Refer to Table 8.

Agitate

Description

Status/Value

Step

 

 

 

 

 

“AgEn”

Agitate Step

“on”/“oFF”

 

Enable/Disable

 

 

 

 

“AdUr”

Agitate Duration

1-30 Minutes for

 

(in minutes)

agitate types 1 or 2

 

 

1-180 Minutes for

 

 

agitate types 3 or 4

 

 

(Refer to Cycle Agitate)

 

 

 

“HEAt”

Heat in Agitate

“oFF”, 1 or 2

 

(If heater is present)

1 = To Target

 

 

2 = Maintain

 

 

 

 

Table 8

 

4.Press the #3 (>) or the #6 (<) keypad to change the current status/value.

5.Press the START (enter) keypad when the desired status/value appears in the display. The next Agitate step option will appear in the display.

NOTE: To program “drAn” (Drain Step), continue to next Cycle Segment option. To program other options, press the #3 (>) or the #6 (<) keypad and refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to Start Mode.

28

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8208801

Image 30
Contents Washer-Extractor Page W030 Contents Temperature Controlled Fill Enable/Disable tCF Model Identification About the Control Power Failure RecoveryPreliminary Information Glossary of TermsControl Identification Select Cycle Pads Refer to FigureDisplay Identification Light Emitting Diodes LEDs Refer to FigureFour 7-Segment Digits Washer-Extractor Operation Special Features Manual Diagnostics Entering the Manual ModeHow to Enter the Manual Mode Manual ProgrammingWhat Can Be Programmed? Option Description Default Value Range Number DisplayProgramming Control Programmable Options AvailableCoLd/Uarn/Hotor FLEnTEnP SUEnProgramming Control Manual Mode Flowchart Manual Programming Flowchart 1 Manual Programming Flowchart 2 Manual Programming Flowchart 3 Option available on software version 2 onlyDiagnostic Tests Flowchart Default Cycle dCYC How to Program Default CycleHow to Exit Programming Feature Audio Signal AUd How to Program the Audio SignalRemove Coin How to Read TableMode Card End Key Input Not Cycle Pressed UsedLEr3 Error Code Programming ErrHow to Program Error Code Programming ESdSAT FRI Thur WED TUE MON SUN SAT FRI Thur WED TUE MON SUN OFF Cycle Programming Cy How to Enter Cycle ProgrammingHow to Program Cycle Agitate AgIt Final Description StatusHow to Program Cycle Segment SEg1 Fill Step Description StatusStep SupplyDescription Status/Value Agitate Description Status/Value StepProgramming Drain Step Extract DescriptionHow to Program Number of Balance Retries Programming Cycle Time DisplayHow to Program Fahrenheit/Celsius IR Access On/Off IrAHow to Program the IR Access On/Off Fahrenheit/Celsius t FCHow to Program Hot Water Temperature Hot Water Temperature FHWarm Water Temperature FHC How to Program Warm Water TemperatureHow to Program Cold Water Temperature Cold Water Temperature FCCooldown Enable/Temperature Codn How to Program Cooldown Enable/ TemperatureProduction Test Cycle On/Off PtEn How to Program the Production Test Cycle On/OffHow to Program the Manual Rapid Advance On/Off Manual Rapid Advance On/Off rAEnNo Cycle Time Display nCtd How to Program in the Cycle Time DisplayHow to Program the Programmable Cycle Time Display Programmable Cycle Time Display PCtdSlow Drain Detection Adjust SdAd How to Program the Pause/Resume ModeHow to Program the Time and Date Set Real-Time Clock rtC-’How to Program Low Water Level Manual Diagnostics On/Off dAEnHow to Program the Manual Diagnostics On/Off Low Water Level FLoMedium Water Level FnEd How to Program Medium Water LevelHow to Program High Water Level High Water Level FHITemperature Controlled Fill Enable/Disable tCF How to Program Temperature Controlled FillHow to Program Auto-Water Leak Detection Auto-Water Leak Detection ALdHow to Exit Audit Feature How to Enter Audit FeatureHow to Read Audit Data Collecting Audit InformationManual Reset How to Enter Manual ResetHow to Start Tests Testing Machine Electronic Control FunctionsHow to Enter Testing Feature How to Exit Testing FeatureD003 D001D002 TxxxDiagnostic Test Descriptions VFD Drive Fault Input Test Temperature Sensor Display TestVAC Switch Input Test Frame Balance Switch Input TestProduction Test Cycle Production Test Cycle Quick Reference Chart Display Test Cycle Step CommentsRAg then LoAg thenAg then DrAI thenError Codes Error Codes DoorRapid Advance Feature How to Use Rapid AdvanceHow to Exit Rapid Advance Feature Communications Mode How to Begin Communications with An External DeviceInfra-red Communications Default Cycles Default Cycles Cycle Stops Reclaim Delicates 90C 60C 40C 90C Perm 60C Perm Cycle reference CY08 CY09 Cycle Stops 40C Perm 70C Perm 50C Gentle 30C Gentle Blank CY17 CY18