Alliance Laundry Systems PHM1263R D001, D002, D003, Txxx, D004, OP or a CL, D009, DrCL or drOP

Page 47

Testing Machine and Electronic Control Functions

Diagnostic (Testing) Mode – Quick Reference Chart

Test Number

Diagnostic Mode

Display

 

 

 

d001

Front End Control Software Version # Test

S xx

 

 

 

d002

Output Board Control Software # Test

o xx

 

 

 

d003

Output Board Water Level Sensor Trim Value

txxx

 

 

 

d004

Access Panel Opening Test

A oP” or A CL

 

 

 

d009

Door Switch Input Test

drCL” or “drOP

 

 

 

d010

Door Lock Input Test

drUL” or “drLO

 

 

 

d011

Show Fill Time Test

Fxxx

 

 

 

d012

Show Drain Time Test

dxxx

 

 

 

d013

Temperature Sensor Display Test

xxxF” or “xxxC

 

 

 

d014

Start Pulse Test

Stxx

 

 

 

d015

VFD Balance Input Test

bAoP” or “bACL

 

 

 

d016

24 VAC Switch Input Test

ACoP” or “ACCL

 

 

 

d017

VFD Drive Fault Input Test

dFoP” or “dFCL

 

 

 

d018

Frame Balance Switch Input Test

FSoP” or “FSCL

 

 

 

d019

VFD Balance Weight Test

bAL

 

 

 

d020

Water Purge Test

PUrg

 

 

 

d021

Water Leak Detection Test

Ld

 

 

 

 

Table 13

 

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

45

Image 47
Contents Washer-Extractor Page W030 Contents Temperature Controlled Fill Enable/Disable tCF Model Identification Glossary of Terms Power Failure RecoveryPreliminary Information About the ControlSelect Cycle Pads Refer to Figure Control IdentificationFour 7-Segment Digits Display IdentificationLight Emitting Diodes LEDs Refer to Figure Washer-Extractor Operation Special Features Manual Programming Entering the Manual ModeHow to Enter the Manual Mode Manual DiagnosticsProgrammable Options Available Option Description Default Value Range Number DisplayProgramming Control What Can Be Programmed?SUEn FLEnTEnP CoLd/Uarn/HotorProgramming Control Manual Mode Flowchart Manual Programming Flowchart 1 Manual Programming Flowchart 2 Option available on software version 2 only Manual Programming Flowchart 3Diagnostic Tests Flowchart How to Exit Programming Feature Default Cycle dCYCHow to Program Default Cycle How to Program the Audio Signal Audio Signal AUdNot Cycle Pressed Used How to Read TableMode Card End Key Input Remove CoinESd Error Code Programming ErrHow to Program Error Code Programming LEr3SAT FRI Thur WED TUE MON SUN SAT FRI Thur WED TUE MON SUN OFF Final Description Status How to Enter Cycle ProgrammingHow to Program Cycle Agitate AgIt Cycle Programming CyFill Step Description Status How to Program Cycle Segment SEg1Agitate Description Status/Value Step SupplyDescription Status/Value StepExtract Description Programming Drain StepProgramming Cycle Time Display How to Program Number of Balance RetriesFahrenheit/Celsius t FC IR Access On/Off IrAHow to Program the IR Access On/Off How to Program Fahrenheit/CelsiusHow to Program Warm Water Temperature Hot Water Temperature FHWarm Water Temperature FHC How to Program Hot Water TemperatureHow to Program Cooldown Enable/ Temperature Cold Water Temperature FCCooldown Enable/Temperature Codn How to Program Cold Water TemperatureManual Rapid Advance On/Off rAEn How to Program the Production Test Cycle On/OffHow to Program the Manual Rapid Advance On/Off Production Test Cycle On/Off PtEnProgrammable Cycle Time Display PCtd How to Program in the Cycle Time DisplayHow to Program the Programmable Cycle Time Display No Cycle Time Display nCtdHow to Program the Pause/Resume Mode Slow Drain Detection Adjust SdAdSet Real-Time Clock rtC-’ How to Program the Time and DateLow Water Level FLo Manual Diagnostics On/Off dAEnHow to Program the Manual Diagnostics On/Off How to Program Low Water LevelHigh Water Level FHI How to Program Medium Water LevelHow to Program High Water Level Medium Water Level FnEdHow to Program Temperature Controlled Fill Temperature Controlled Fill Enable/Disable tCFAuto-Water Leak Detection ALd How to Program Auto-Water Leak DetectionCollecting Audit Information How to Enter Audit FeatureHow to Read Audit Data How to Exit Audit FeatureHow to Enter Manual Reset Manual ResetHow to Exit Testing Feature Testing Machine Electronic Control FunctionsHow to Enter Testing Feature How to Start TestsTxxx D001D002 D003Diagnostic Test Descriptions Frame Balance Switch Input Test Temperature Sensor Display TestVAC Switch Input Test VFD Drive Fault Input TestProduction Test Cycle Display Test Cycle Step Comments Production Test Cycle Quick Reference ChartDrAI then LoAg thenAg then RAg thenError Codes Door Error CodesHow to Exit Rapid Advance Feature Rapid Advance FeatureHow to Use Rapid Advance Infra-red Communications Communications ModeHow to Begin Communications with An External Device Default Cycles Default Cycles Cycle Stops Reclaim Delicates 90C 60C 40C 90C Perm 60C Perm Cycle reference CY08 CY09 Cycle Stops 40C Perm 70C Perm 50C Gentle 30C Gentle Blank CY17 CY18