Alliance Laundry Systems PHM1263R manual Error Codes

Page 53

Error Codes

Following is a list of possible error codes for an electronic control. Errors beginning with “EI” refer to external device Infra-red communication errors. All other errors refer to machine errors.

Display

Description

 

Cause/

 

Corrective Action

 

 

 

 

 

 

 

EI01

Transmission Failure

 

Communication failure. Re-aim external device and try again.

 

 

 

 

EI02

Time-out Error

 

Communication failure. Re-aim external device and try again.

 

 

 

 

EI03

Invalid Command Code

 

Communication successful, but the command was not valid

 

 

 

for this machine type, or the control could not perform the

 

 

 

command in its current mode of operation. Ensure data is for

 

 

 

current machine type and control is in correct mode.

 

 

 

 

EI04

Expecting Upload Request

 

Communication failure. Re-aim external device and try again.

 

 

 

 

EI05

Invalid or Out-of-Range Data

 

The value in at least one of the programming options is

 

 

 

invalid or out of range. Recheck the programming option’s

 

 

 

value and try again.

 

 

 

 

EI09

CRC-16 Error

 

Communication failure. Re-aim external device and try again.

 

 

 

 

EI0A

Framing Error

 

Communication error. Re-aim external device and try again.

 

 

 

 

EI0C

Time-out Exceeded

 

Communication error. Re-aim external device and try again.

 

 

 

 

EI0E

Encryption Error

 

Communication error. Re-aim external device and try again.

 

 

 

If the problem persists, check that the security code is correct.

 

 

 

 

EI0F

Infra-red Disabled

 

Communication failure or infra-red is disabled. Manually

 

 

 

enable infra-red on control or re-aim external device and try

 

 

 

again.

 

 

 

 

E FL

Fill Error

 

Programmed water level not reached within 10 minutes (or

 

 

 

other programmed length of time) in any fill agitate cycle.

 

 

 

End cycle. Power down machine to clear.

 

 

 

 

E SP

SPI Communications Error

 

Front End control cannot communicate with output board.

 

 

 

Power down the machine, power up and try again.

 

 

 

 

 

 

Table 16 (continued)

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

51

Image 53
Contents Washer-Extractor Page W030 Contents Temperature Controlled Fill Enable/Disable tCF Model Identification Preliminary Information Power Failure RecoveryAbout the Control Glossary of TermsSelect Cycle Pads Refer to Figure Control IdentificationFour 7-Segment Digits Display IdentificationLight Emitting Diodes LEDs Refer to Figure Washer-Extractor Operation Special Features How to Enter the Manual Mode Entering the Manual ModeManual Diagnostics Manual ProgrammingProgramming Control Option Description Default Value Range Number DisplayWhat Can Be Programmed? Programmable Options AvailableTEnP FLEnCoLd/Uarn/Hotor SUEnProgramming Control Manual Mode Flowchart Manual Programming Flowchart 1 Manual Programming Flowchart 2 Option available on software version 2 only Manual Programming Flowchart 3Diagnostic Tests Flowchart How to Exit Programming Feature Default Cycle dCYCHow to Program Default Cycle How to Program the Audio Signal Audio Signal AUdMode Card End Key Input How to Read TableRemove Coin Not Cycle Pressed UsedHow to Program Error Code Programming Error Code Programming ErrLEr3 ESdSAT FRI Thur WED TUE MON SUN SAT FRI Thur WED TUE MON SUN OFF How to Program Cycle Agitate AgIt How to Enter Cycle ProgrammingCycle Programming Cy Final Description StatusFill Step Description Status How to Program Cycle Segment SEg1Description Status/Value SupplyStep Agitate Description Status/Value StepExtract Description Programming Drain StepProgramming Cycle Time Display How to Program Number of Balance RetriesHow to Program the IR Access On/Off IR Access On/Off IrAHow to Program Fahrenheit/Celsius Fahrenheit/Celsius t FCWarm Water Temperature FHC Hot Water Temperature FHHow to Program Hot Water Temperature How to Program Warm Water TemperatureCooldown Enable/Temperature Codn Cold Water Temperature FCHow to Program Cold Water Temperature How to Program Cooldown Enable/ TemperatureHow to Program the Manual Rapid Advance On/Off How to Program the Production Test Cycle On/OffProduction Test Cycle On/Off PtEn Manual Rapid Advance On/Off rAEnHow to Program the Programmable Cycle Time Display How to Program in the Cycle Time DisplayNo Cycle Time Display nCtd Programmable Cycle Time Display PCtdHow to Program the Pause/Resume Mode Slow Drain Detection Adjust SdAdSet Real-Time Clock rtC-’ How to Program the Time and DateHow to Program the Manual Diagnostics On/Off Manual Diagnostics On/Off dAEnHow to Program Low Water Level Low Water Level FLoHow to Program High Water Level How to Program Medium Water LevelMedium Water Level FnEd High Water Level FHIHow to Program Temperature Controlled Fill Temperature Controlled Fill Enable/Disable tCFAuto-Water Leak Detection ALd How to Program Auto-Water Leak DetectionHow to Read Audit Data How to Enter Audit FeatureHow to Exit Audit Feature Collecting Audit InformationHow to Enter Manual Reset Manual ResetHow to Enter Testing Feature Testing Machine Electronic Control FunctionsHow to Start Tests How to Exit Testing FeatureD002 D001D003 TxxxDiagnostic Test Descriptions VAC Switch Input Test Temperature Sensor Display TestVFD Drive Fault Input Test Frame Balance Switch Input TestProduction Test Cycle Display Test Cycle Step Comments Production Test Cycle Quick Reference ChartAg then LoAg thenRAg then DrAI thenError Codes Door Error CodesHow to Exit Rapid Advance Feature Rapid Advance FeatureHow to Use Rapid Advance Infra-red Communications Communications ModeHow to Begin Communications with An External Device Default Cycles Default Cycles Cycle Stops Reclaim Delicates 90C 60C 40C 90C Perm 60C Perm Cycle reference CY08 CY09 Cycle Stops 40C Perm 70C Perm 50C Gentle 30C Gentle Blank CY17 CY18