Programming Drain Step

1.When “drAn” appears in the display, press the START (enter) keypad. The current status will be displayed.

2.Press the #3 (>) or the #6 (<) keypad to change the current status.

on” = Drain step is enabled “oFF” = Drain step is disabled

NOTE: Drain must be enabled to activate Extract step.

3.Press the START (enter) keypad when the desired status appears in the display. The next Cycle Segment option, “SPIn”, will appear in the display.

NOTE: To program “SPIn” (Extract Step), continue to next Cycle Segment option. To program other options press the #3 (>) or the #6 (<) keypad and refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to Ready Mode.

Programming Extract Step

1.When “SPIn” appears in the display, press the START (enter) keypad. The first Extract step programming option will appear in the display.

2.Press the #3 (>) or the #6 (<) keypad to scroll through the programmable Extract step options. Refer to Table 9.

NOTE: Extract Step “SPEn” must be enabled to scroll through all Extract step options.

3.Press the START (enter) keypad when the desired option appears in the display. The current status/value will appear in the display. Refer to Table 9.

 

 

 

Programming Control

M

 

 

 

 

Extract

Description

Status/Value

 

 

Step

 

 

 

 

“SPEn”

Extract Step

“on”/“oFF”

 

 

 

Enable/

 

 

 

 

Disable

 

 

 

 

 

 

 

 

“SSEC”

Extract

0-59

 

 

 

Seconds

 

 

 

 

 

 

 

 

“SnIn”

Extract

Intermediate Extract:

 

 

 

Minutes

Minimum

 

 

 

 

Step Time = 30 seconds

 

 

 

 

Maximum

 

 

 

 

Step Time = 3:59 minutes

 

 

 

 

Final Extract:

 

 

 

 

Minimum

 

 

 

 

Step Time = 30 seconds

 

 

 

 

Maximum

 

 

 

 

Step Time = 9:59 minutes

 

 

 

 

 

 

 

“SSPd”

Extract Speed

1 = very low speed (60g)

 

 

 

(VFD only)

2 = low speed

 

 

 

 

(L-speed = 100g;

 

 

 

 

M-speed = 120g)

 

 

 

 

3 = medium speed

 

 

 

 

(L-speed = 100g;

 

 

 

 

M-speed = 180g)

 

 

 

 

 

 

Table 9

4.Press the #3 (>) or the #6 (<) keypad to change the current status/value.

5.Press the START (enter) keypad when the desired status/value appears in the display.

NOTE: To program “Cnin” (Cycle Time Display), continue to next Cycle Segment option. To program other options press the #3 (>) or the #6 (<) keypad and refer to the appropriate section.

How to Exit Programming Feature

Press the #5 (<) keypad until the control returns to Start Mode.

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

29

Image 31
Contents Washer-Extractor Page W030 Contents Temperature Controlled Fill Enable/Disable tCF Model Identification Glossary of Terms Power Failure RecoveryPreliminary Information About the ControlSelect Cycle Pads Refer to Figure Control IdentificationLight Emitting Diodes LEDs Refer to Figure Display IdentificationFour 7-Segment Digits Washer-Extractor Operation Special Features Manual Programming Entering the Manual ModeHow to Enter the Manual Mode Manual DiagnosticsProgrammable Options Available Option Description Default Value Range Number DisplayProgramming Control What Can Be Programmed?SUEn FLEnTEnP CoLd/Uarn/HotorProgramming Control Manual Mode Flowchart Manual Programming Flowchart 1 Manual Programming Flowchart 2 Option available on software version 2 only Manual Programming Flowchart 3Diagnostic Tests Flowchart How to Program Default Cycle Default Cycle dCYCHow to Exit Programming Feature How to Program the Audio Signal Audio Signal AUdNot Cycle Pressed Used How to Read TableMode Card End Key Input Remove CoinESd Error Code Programming ErrHow to Program Error Code Programming LEr3SAT FRI Thur WED TUE MON SUN SAT FRI Thur WED TUE MON SUN OFF Final Description Status How to Enter Cycle ProgrammingHow to Program Cycle Agitate AgIt Cycle Programming CyFill Step Description Status How to Program Cycle Segment SEg1Agitate Description Status/Value Step SupplyDescription Status/Value StepExtract Description Programming Drain StepProgramming Cycle Time Display How to Program Number of Balance RetriesFahrenheit/Celsius t FC IR Access On/Off IrAHow to Program the IR Access On/Off How to Program Fahrenheit/CelsiusHow to Program Warm Water Temperature Hot Water Temperature FHWarm Water Temperature FHC How to Program Hot Water TemperatureHow to Program Cooldown Enable/ Temperature Cold Water Temperature FCCooldown Enable/Temperature Codn How to Program Cold Water TemperatureManual Rapid Advance On/Off rAEn How to Program the Production Test Cycle On/OffHow to Program the Manual Rapid Advance On/Off Production Test Cycle On/Off PtEnProgrammable Cycle Time Display PCtd How to Program in the Cycle Time DisplayHow to Program the Programmable Cycle Time Display No Cycle Time Display nCtdHow to Program the Pause/Resume Mode Slow Drain Detection Adjust SdAdSet Real-Time Clock rtC-’ How to Program the Time and DateLow Water Level FLo Manual Diagnostics On/Off dAEnHow to Program the Manual Diagnostics On/Off How to Program Low Water LevelHigh Water Level FHI How to Program Medium Water LevelHow to Program High Water Level Medium Water Level FnEdHow to Program Temperature Controlled Fill Temperature Controlled Fill Enable/Disable tCFAuto-Water Leak Detection ALd How to Program Auto-Water Leak DetectionCollecting Audit Information How to Enter Audit FeatureHow to Read Audit Data How to Exit Audit FeatureHow to Enter Manual Reset Manual ResetHow to Exit Testing Feature Testing Machine Electronic Control FunctionsHow to Enter Testing Feature How to Start TestsTxxx D001D002 D003Diagnostic Test Descriptions Frame Balance Switch Input Test Temperature Sensor Display TestVAC Switch Input Test VFD Drive Fault Input TestProduction Test Cycle Display Test Cycle Step Comments Production Test Cycle Quick Reference ChartDrAI then LoAg thenAg then RAg thenError Codes Door Error CodesHow to Use Rapid Advance Rapid Advance FeatureHow to Exit Rapid Advance Feature How to Begin Communications with An External Device Communications ModeInfra-red Communications Default Cycles Default Cycles Cycle Stops Reclaim Delicates 90C 60C 40C 90C Perm 60C Perm Cycle reference CY08 CY09 Cycle Stops 40C Perm 70C Perm 50C Gentle 30C Gentle Blank CY17 CY18