Alliance Laundry Systems PHM1263R manual Default Cycles

Page 57

Default Cycles

 

Perm Press

Cotton/Terry

Perm Press

Cotton/Terry

Perm Press

Cotton/Terry

Rags Heavy

Cycle Stops

Light

Light

Medium Soil

Medium Soil

Heavy Soil

Heavy Soil

Soil

 

Soil

Soil

 

 

 

 

 

Cycle reference

CY01

CY02

CY03

CY04

CY05

CY06

CY07

(display in Program Mode)

 

 

 

 

 

 

 

Agitation type

18/3/18

18/3/18

18/3/18

18/3/18

18/3/18

18/3/18

18/3/18

Normal

Normal

Normal

Normal

Normal

Normal

Normal

 

 

 

 

 

 

 

 

 

Wash 1 (Wash - ON/OFF)

ON

ON

ON

ON

ON

ON

ON

Time for agitation (min.)

7

7

2

2

2

2

2

Fill Temperature

Hot

Hot

Warm

Warm

Warm

Warm

Warm

Fill Level

Low

Low

High

High

High

High

High

Supply

S1, S2

S1, S2

OFF

OFF

OFF

OFF

OFF

Heat (if enabled)

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Drain

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Spin (min.)

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

Wash 2 (Wash - ON/OFF)

OFF

OFF

ON

ON

ON

ON

ON

Time for agitation (min.)

2

2

6

6

7

7

10

Fill Temperature

Cold

Cold

Hot

Hot

Hot

Hot

Hot

Fill Level

Low

Low

Low

Low

Low

Low

Low

Supply

OFF

OFF

S1

S1

S1

S1

S1

Heat (if enabled)

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Drain

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Spin (min.)

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

Wash 3 (Wash - ON/OFF)

OFF

OFF

ON

ON

ON

ON

ON

Time for agitation (min.)

2

2

6

7

7

7

6

Fill Temperature

Cold

Cold

Hot

Hot

Hot

Hot

Hot

Fill Level

Low

Low

Low

Low

Low

Low

High

Supply

OFF

OFF

S2

S2

S2

S2

S2

Heat (if enabled)

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Drain

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Spin (min.)

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

Wash 4 (Wash - ON/OFF)

OFF

OFF

OFF

OFF

OFF

OFF

OFF

Time for agitation (min.)

2

2

2

2

2

2

2

Fill Temperature

Cold

Cold

Cold

Cold

Cold

Cold

Cold

Fill Level

Low

Low

Low

Low

Low

Low

Low

Supply

OFF

OFF

OFF

OFF

OFF

OFF

OFF

Heat (if enabled)

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Drain

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Spin (min.)

0

0

0

0

0

0

0

(continued)

F8208801

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

55

Image 57
Contents Washer-Extractor Page W030 Contents Temperature Controlled Fill Enable/Disable tCF Model Identification Preliminary Information Power Failure RecoveryAbout the Control Glossary of TermsSelect Cycle Pads Refer to Figure Control IdentificationDisplay Identification Light Emitting Diodes LEDs Refer to FigureFour 7-Segment Digits Washer-Extractor Operation Special Features How to Enter the Manual Mode Entering the Manual ModeManual Diagnostics Manual ProgrammingProgramming Control Option Description Default Value Range Number DisplayWhat Can Be Programmed? Programmable Options AvailableTEnP FLEnCoLd/Uarn/Hotor SUEnProgramming Control Manual Mode Flowchart Manual Programming Flowchart 1 Manual Programming Flowchart 2 Option available on software version 2 only Manual Programming Flowchart 3Diagnostic Tests Flowchart Default Cycle dCYC How to Program Default CycleHow to Exit Programming Feature How to Program the Audio Signal Audio Signal AUdMode Card End Key Input How to Read TableRemove Coin Not Cycle Pressed UsedHow to Program Error Code Programming Error Code Programming ErrLEr3 ESdSAT FRI Thur WED TUE MON SUN SAT FRI Thur WED TUE MON SUN OFF How to Program Cycle Agitate AgIt How to Enter Cycle ProgrammingCycle Programming Cy Final Description StatusFill Step Description Status How to Program Cycle Segment SEg1Description Status/Value SupplyStep Agitate Description Status/Value StepExtract Description Programming Drain StepProgramming Cycle Time Display How to Program Number of Balance RetriesHow to Program the IR Access On/Off IR Access On/Off IrAHow to Program Fahrenheit/Celsius Fahrenheit/Celsius t FCWarm Water Temperature FHC Hot Water Temperature FHHow to Program Hot Water Temperature How to Program Warm Water TemperatureCooldown Enable/Temperature Codn Cold Water Temperature FCHow to Program Cold Water Temperature How to Program Cooldown Enable/ TemperatureHow to Program the Manual Rapid Advance On/Off How to Program the Production Test Cycle On/OffProduction Test Cycle On/Off PtEn Manual Rapid Advance On/Off rAEnHow to Program the Programmable Cycle Time Display How to Program in the Cycle Time DisplayNo Cycle Time Display nCtd Programmable Cycle Time Display PCtdHow to Program the Pause/Resume Mode Slow Drain Detection Adjust SdAdSet Real-Time Clock rtC-’ How to Program the Time and DateHow to Program the Manual Diagnostics On/Off Manual Diagnostics On/Off dAEnHow to Program Low Water Level Low Water Level FLoHow to Program High Water Level How to Program Medium Water LevelMedium Water Level FnEd High Water Level FHIHow to Program Temperature Controlled Fill Temperature Controlled Fill Enable/Disable tCFAuto-Water Leak Detection ALd How to Program Auto-Water Leak DetectionHow to Read Audit Data How to Enter Audit FeatureHow to Exit Audit Feature Collecting Audit InformationHow to Enter Manual Reset Manual ResetHow to Enter Testing Feature Testing Machine Electronic Control FunctionsHow to Start Tests How to Exit Testing FeatureD002 D001D003 TxxxDiagnostic Test Descriptions VAC Switch Input Test Temperature Sensor Display TestVFD Drive Fault Input Test Frame Balance Switch Input TestProduction Test Cycle Display Test Cycle Step Comments Production Test Cycle Quick Reference ChartAg then LoAg thenRAg then DrAI thenError Codes Door Error CodesRapid Advance Feature How to Use Rapid AdvanceHow to Exit Rapid Advance Feature Communications Mode How to Begin Communications with An External DeviceInfra-red Communications Default Cycles Default Cycles Cycle Stops Reclaim Delicates 90C 60C 40C 90C Perm 60C Perm Cycle reference CY08 CY09 Cycle Stops 40C Perm 70C Perm 50C Gentle 30C Gentle Blank CY17 CY18