Alliance Laundry Systems PHM1263R manual Contents

Page 4

Table of

Model Identification

4

Preliminary Information

5

Contents

Glossary of Terms

5

 

About the Control

5

 

Power Failure Recovery

5

 

Communications

5

 

Control Identification

6

 

Select Cycle Pads

6

 

Display Identification

7

 

Light Emitting Diodes (LEDs)

7

 

Washer-Extractor Operation

8

 

Start Up

8

 

Door Locking Mode

8

 

Stop Mode

8

 

Start Mode

8

 

End of Cycle Mode

8

 

Cycle Sequence

8

 

Run Mode

8

 

Signals

8

 

Special Features

9

 

Programming Control

9

 

Collecting Audit Information

9

 

Testing Machine and Control Functions

9

 

Rapid Advance Feature

9

 

Communications Mode

9

 

Entering the Manual Mode

10

 

How to Enter the Manual Mode

10

 

Manual Diagnostics

10

 

Programming Control

11

 

What Can Be Programmed?

11

 

Programmable Options Available

11

 

Manual Mode Flowchart

14

 

Manual Programming Flowchart (1 of 3)

15

 

Manual Programming Flowchart (2 of 3)

16

 

Manual Programming Flowchart (3 of 3)

17

 

Diagnostic Tests Flowchart

18

 

1.

Default Cycle “dCYC”

19

 

2.

Audio Signal “AUd”

20

 

3.

Error Code Programming “Err-”

22

 

4.

Cycle Programming “Cy--”

26

 

5.

Number of Balance Retries “bALr”

 

 

 

(Variable Frequency Drives Only)

30

 

6.

IR Access (On/Off) “IrA”

31

 

7.

Fahrenheit/Celsius “t FC”

31

 

8.

Hot Water Temperature “FH”

32

 

9.

Warm Water Temperature “FHC”

32

 

10.

Cold Water Temperature “FC”

33

 

11.

Cooldown Enable/Temperature “Codn”

33

 

12.

Production Test Cycle (On/Off) “PtEn”

34

 

13.

Manual Rapid Advance (On/Off) “rAEn”

34

 

14.

No Cycle Time Display “nCtd”

35

 

15.

Programmable Cycle Time Display “PCtd”

35

© Copyright 2010, Alliance Laundry Systems LLC

All rights reserved. No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher.

2

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

F8208801

Image 4
Contents Washer-Extractor Page W030 Contents Temperature Controlled Fill Enable/Disable tCF Model Identification Power Failure Recovery Preliminary InformationAbout the Control Glossary of TermsControl Identification Select Cycle Pads Refer to FigureLight Emitting Diodes LEDs Refer to Figure Display IdentificationFour 7-Segment Digits Washer-Extractor Operation Special Features Entering the Manual Mode How to Enter the Manual ModeManual Diagnostics Manual ProgrammingOption Description Default Value Range Number Display Programming ControlWhat Can Be Programmed? Programmable Options AvailableFLEn TEnPCoLd/Uarn/Hotor SUEnProgramming Control Manual Mode Flowchart Manual Programming Flowchart 1 Manual Programming Flowchart 2 Manual Programming Flowchart 3 Option available on software version 2 onlyDiagnostic Tests Flowchart How to Program Default Cycle Default Cycle dCYCHow to Exit Programming Feature Audio Signal AUd How to Program the Audio SignalHow to Read Table Mode Card End Key InputRemove Coin Not Cycle Pressed UsedError Code Programming Err How to Program Error Code ProgrammingLEr3 ESdSAT FRI Thur WED TUE MON SUN SAT FRI Thur WED TUE MON SUN OFF How to Enter Cycle Programming How to Program Cycle Agitate AgItCycle Programming Cy Final Description StatusHow to Program Cycle Segment SEg1 Fill Step Description StatusSupply Description Status/ValueStep Agitate Description Status/Value StepProgramming Drain Step Extract DescriptionHow to Program Number of Balance Retries Programming Cycle Time DisplayIR Access On/Off IrA How to Program the IR Access On/OffHow to Program Fahrenheit/Celsius Fahrenheit/Celsius t FCHot Water Temperature FH Warm Water Temperature FHCHow to Program Hot Water Temperature How to Program Warm Water TemperatureCold Water Temperature FC Cooldown Enable/Temperature CodnHow to Program Cold Water Temperature How to Program Cooldown Enable/ TemperatureHow to Program the Production Test Cycle On/Off How to Program the Manual Rapid Advance On/OffProduction Test Cycle On/Off PtEn Manual Rapid Advance On/Off rAEnHow to Program in the Cycle Time Display How to Program the Programmable Cycle Time DisplayNo Cycle Time Display nCtd Programmable Cycle Time Display PCtdSlow Drain Detection Adjust SdAd How to Program the Pause/Resume ModeHow to Program the Time and Date Set Real-Time Clock rtC-’Manual Diagnostics On/Off dAEn How to Program the Manual Diagnostics On/OffHow to Program Low Water Level Low Water Level FLoHow to Program Medium Water Level How to Program High Water LevelMedium Water Level FnEd High Water Level FHITemperature Controlled Fill Enable/Disable tCF How to Program Temperature Controlled FillHow to Program Auto-Water Leak Detection Auto-Water Leak Detection ALdHow to Enter Audit Feature How to Read Audit DataHow to Exit Audit Feature Collecting Audit InformationManual Reset How to Enter Manual ResetTesting Machine Electronic Control Functions How to Enter Testing FeatureHow to Start Tests How to Exit Testing FeatureD001 D002D003 TxxxDiagnostic Test Descriptions Temperature Sensor Display Test VAC Switch Input TestVFD Drive Fault Input Test Frame Balance Switch Input TestProduction Test Cycle Production Test Cycle Quick Reference Chart Display Test Cycle Step CommentsLoAg then Ag thenRAg then DrAI thenError Codes Error Codes DoorHow to Use Rapid Advance Rapid Advance FeatureHow to Exit Rapid Advance Feature How to Begin Communications with An External Device Communications ModeInfra-red Communications Default Cycles Default Cycles Cycle Stops Reclaim Delicates 90C 60C 40C 90C Perm 60C Perm Cycle reference CY08 CY09 Cycle Stops 40C Perm 70C Perm 50C Gentle 30C Gentle Blank CY17 CY18