C. ELECTRICAL SERVICE SPECIFICATIONS

1.Gas Models

ADG-464 (GAS)

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)*

IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.

B.Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3Ø dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

FUSING

CIRCUIT

AMP DRAW

 

Dual Element

VOLTAGE

SERVICE

BREAKER

 

 

 

60 Hz

50 Hz

Time Delay

 

208

3/4

107

---

150

150

240

3/4

101

98

150

150

380-400

3/4

---

53

80

90

416

3/4

---

51

60

90

460/480

3/4

51

---

60

90

DEDICATED SPRINKLER SERVICE**

Dryer Nameplate

---

2

3.5

5

*Contact factory for information not listed.

**Minimum wire size is #16 AWG Stranded Type Wire...for individual lengths less than 100 feet.

2.Steam Models

ADS-464 (STEAM)

ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)*

IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.

NOTES: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.

B.Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw rating and type of breaker used.

C.Circuit breakers for 3Ø dryers must be 3-pole type.

SERVICE

PHASE

WIRE

APPROX.

FUSING

CIRCUIT

AMP DRAW

 

Dual Element

VOLTAGE

SERVICE

BREAKER

 

 

 

60 Hz

50 Hz

Time Delay

 

200

3

117

---

150

150

208

3/4

102

---

150

150

240

3/4

96

94

125

150

380-400

3/4

---

51

60

90

416

3/4

---

51

60

90

460/480

3/4

49

---

60

90

DEDICATED SPRINKLER SERVICE**

Dryer Nameplate

---

2

3.5

5

*Contact factory for information not listed.

**Minimum wire size is #16 AWG Stranded Type Wire...for individual lengths less than 100 feet.

NOTE: ADC reserves the right to make changes in specifications at any time, without notice or obligation.

11

Image 15
Contents American Dryer Corporation Important Note to Purchaser Retain This Manual In a Safe Place For Future ReferenceFor Your Safety Page Table of Contents Section Pendant Assembly Section Sprinkler SystemSection AIR JET System Explosion could Result Safety PrecautionsNational Electric Code ANSI/NFPA no -LATEST Edition StandardsRoutine Maintenance CleaningLiquids Monthly Lubrication Days After Installation and Every 6 Months Thereafter AdjustmentsGAS Models ADG-464 SpecificationsSteam Models ADS-464 ADG-464 GAS Electrical Service SpecificationsEnclosure / AIR Supply / Exhaust Requirements Installation RequirementsElectrical Requirements and GAS Requirements Operational Service Check ProcedureTumbler Support and Drive System Component DESCRIPTION/REPLACEMENTPage Main AIR BLOWER/HEAT Reclaimer System +Z=X Compressed AIR System Filter element can be cleaned with soap and waterPage Page Page Safety Devices Safety Devices Locations/Functions/Messages Blower Squirrel Cage Fan Motor Assembly Pulley Removal Page Important do not Overtighten V-BELTS FreelyImportant do not Overtighten V-BELTS Blower Squirrel Cage Fan Electrical Components Page Tumbler Basket System Page Page Important do not Overtighten Turnbuckle Important do not Overtighten Turnbuckle Result in Damage to the Dryer and will Void the Warranty Important do not Overtighten Bolts Page Current Limiting Device is Required Rotational Sensor AssemblyPage TOP of Tumbler Basket Temperature Door Assembly Tumbler Basket Electrical Components Page PLC Programmable Logic Controller Description PLC Programmable Logic Controller SystemPage Page 111 PLC Programmable Logic Controller Component Replacement Page Page RTD Page Switch #1 Recycling Mode Page Page Page Combustion Air Damper Page Page Page Burner Air Switch Page Page Page Page Page Page Heat Reclaimer Settings Page Page Important Allow a full 72 hours for the silicone to cure Page Page Page Page Base Section Lint DRAWER/LINT Chamber SwitchesPage Page Resistive Temperature Device RTD RTD Resistive Temperature Device Locations Sprinkler System Description Sprinkler SystemPage MAN3190 Page AIR JET System AIR JET SystemPneumatic Valve Stack Valve AssemblyImportant Take Notice ... small components Page MAN4223 Internal Pilot and External Pilot Air Supply Pendant Assembly Description Pendant AssemblyADC450186 05/27/99-25 01/14/00-15